COMMUNICATOR REPORTING CODES
✦ The 4 by 2 |
|
|
|
|
|
|
|
|
| ADEMCO REPORTING CODES |
|
| |||
code for each event has a factory set value. |
|
|
|
| |||
| EVENT |
| ALARM CODE |
| EXTENDED CODE | ||
These values may be customized to fit |
|
|
| ||||
the specific installation and the reporting | SENSOR EMERGENCY |
| E120 |
| C0xx | ||
requirements of the Central Station monitoring | CONSOLE EMERGENCY |
| E120 |
| C026 | ||
the system. | SENSOR FIRE |
| E111 |
| C0xx | ||
✦ If Point ID reporting is enabled (the factory |
|
|
|
|
| ||
CONSOLE FIRE |
| E110 |
| C025 | |||
default setting), each sensor can report a unique |
|
|
|
|
| ||
BURGLARY ALARM |
| E130 |
| C0xx | |||
alarm and trouble code. |
|
|
|
|
|
|
|
SILENT PANIC |
| E122 |
| C0xx | |||
✦ If Point ID is disabled, the “general” reporting |
|
| |||||
|
|
|
|
|
|
| |
FORCE ARM |
| E574 |
| C000 | |||
codes for each event type will be used. |
|
| |||||
|
|
|
|
|
|
| |
DURESS |
| E121 |
| C000 | |||
✦ Each programming function is performed with |
|
| |||||
|
|
|
|
|
|
| |
CANCEL |
| E406 |
| C000 | |||
similar keystrokes. After the system is in Setup |
|
| |||||
|
|
|
|
|
|
| |
SENSOR LOW BATTERY |
| E384 |
| C0xx | |||
Mode, enter the programming step number and |
|
| |||||
|
|
|
|
|
|
| |
SENSOR STATUS TROUBLE |
| E381 |
| C0xx | |||
press HOME, then enter the new value and press |
|
| |||||
|
|
|
|
|
|
| |
AWAY. For reference, follow the figures next to the | CONSOLE LOW BATTERY |
| E302 |
| C000 | ||
programming steps. | CONSOLE BATTERY RESTORE |
| R302 |
| C000 | ||
✴ If the new value is accepted, a “Bing” will sound. If the |
| E606 |
| C000 | |||
new value is not accepted, a “Double Buzz” will sound. |
| xx = SENSOR NUMBER IN EXTENDED REPORT | |||||
✦ Making a value 0 causes the event not to |
|
|
|
|
|
|
|
communicate to the Central Station. |
|
|
|
|
|
|
|
|
|
| ENTERS PROGRAM STEP |
| |||
✎ NOTE: The reporting codes are fixed for opening |
|
|
|
| |||
and closing. A unique code is reserved for the |
|
|
| NUMBER TO MODIFY |
|
| |
master and the five restricted user codes. See the |
|
|
|
|
|
|
|
Opening & Closing Reporting Codes Table. |
|
|
|
|
|
|
|
|
|
|
| STORES NEW VALUE |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
GENERAL REPORTING CODES
✦Use program Steps #201 - 206 to change the
communicator reporting codes when Point ID is |
| |
disabled. | PROGRAMMING | |
✦ Refer to the General Reporting Codes table to | ||
STEPS #201 - 206 | ||
view/edit the reporting codes for each of the five |
| |
events. The factory settings are listed, along with a |
| |
blank area to write in the new installation values. | ENTERS STEP NUMBER | |
STEPS | 0 - 99 FOR GENERAL | |
Any value from | ALARM REPORTING CODE | |
each event using these steps (enter “0” to stop | STORES VALUE - 1 BING | |
an event from reporting). | ||
|
✎NOTE: Be careful not to duplicate codes unless the Central Station requires specific codes for certain types of events.
GENERAL REPORTING CODES
STEP # | PROGRAMMING FUNCTION |
| POSSIBLE 4 BY 2 VALUES |
| FACTORY 4 BY 2 VALUES | INSTALLATION 4 BY 2 VALUE |
|
|
|
|
|
|
|
201 | GENERAL FIRE REPORT CODE |
| 0 - 99 |
| 1 |
|
|
|
|
|
|
|
|
202 | GENERAL EMERGENCY REPORT CODE |
| 0 - 99 |
| 2 |
|
|
|
|
|
|
|
|
203 | GENERAL SILENT PANIC REPORT CODE |
| 0 - 99 |
| 3 |
|
|
|
|
|
|
|
|
204 | GENERAL BURGLARY REPORT CODE |
| 0 - 99 |
| 4 |
|
|
|
|
|
|
|
|
206 | GENERAL TROUBLE REPORT CODE |
| 0 - 99 |
| 6 |
|
|
|
|
|
|
|
|
|
| General Reporting Codes Table |
|
|
42