Linear DUAL 824 manual Home Mode, Manual Bypassing of Sensors, Secure Exit, Home Instant Mode

Page 24

HOME MODE

Use this mode when sleeping or when anyone is staying inside.

Home Mode causes an instant alarm when any perimeter sensor is triggered.

Home Mode causes a delayed alarm when any exit/entry sensor is triggered (except in Home Instant Mode when they are instant).

Each burglary sensor can trigger the siren once per arming period.

Alarm siren stops automatically after five minutes and the system will remain armed.

Home Mode ignores all interior sensors (motion detectors, etc.).

1A. Arm to Home Mode by entering a user code, and pressing HOME.

1B. The user can “Quick Arm” to Home Mode from Off or Chime Mode by pressing HOME for two seconds. (Quick arming can be disabled; see the “Advanced Programming” section of this manual.)

MANUAL BYPASSING OF SENSORS

Manual bypassing of sensors in the Home Mode allows arming of the system at night with open windows, while still having perimeter protection with other closed doors and windows.

If the READY indicator is lit, all sensors are closed.

1. If the READY indicator is not lit, the system will resist arming because of open door or window sensors.

Four high-low Beeps to warn the user that something is open and the system will remain in the previous mode.

Lit sensor status indicators show which sensors are open.

2.To manually bypass the open sensors, arm the system again within five seconds.

A “Gong” and two “Beeps” will sound, the HOME indicator will light, and the open sensors will be bypassed.

WARNING: Bypassed sensors cannot cause an alarm. Closing the sensor removes the bypass.

When the system is armed to the Home Mode, the keypad(s) will sound a “Gong” and two “Beeps”.

2.Enter a user code and press OFF or CHIME to disarm from Home Mode and/or stop the alarm siren.

If an alarm has occurred, multiple Beeps will sound after disarming and the sensor indicator for the sensor(s) that caused the alarm will fl ash (switch to Off Mode again or re-arm the system to stop the fl ashing alarm memory).

SECURE EXIT

1.If the system is already in the Home Mode and the user wants to exit the premises while leaving someone inside with the system still in Home Mode, enter a user code and press the HOME key.

The HOME light will blink for 60 seconds. No exit delay Beeps will sound during the Exit Delay.

2A. The user can leave through a door with a delayed perimeter sensor during the 60 second Exit Delay without causing the Control Panel to begin an Entry Delay.

HOME MODE

START IN OFF

OR CHIME MODE (OPTIONAL)

YOUR

USER

CODE

1GONG & 2 BEEPS

DONE

SECURE EXIT

START IN HOME MODE

(OPTIONAL)

YOUR

USER

CODE

1GONG & 2 BEEPS

DONE

2B. Re-entering during the silent Exit Delay will extend the Exit Delay another 60 seconds (one time only).

NOTE: The Exit Delay time can be changed; see the “Advanced Programming” section of this manual.

HOME INSTANT MODE

1.If the system is already in the Home Mode and the user wants to make all exit/entry sensors instant, press HOME for two seconds.

Two “Gongs” and two “Beeps” will sound and the HOME light and ARMED indicator will blink continuously.

2.Because all exit/entry sensors will now cause an instant alarm when in Home Mode, the system must be disarmed before opening any exit/entry delay door.

NOTE: If quick arming is disabled the Home Instant Mode is unavailable.

OR QUICK ARM TO HOME MODE

START IN OFF

OR CHIME MODE

HOLD DOWN

1 GONG & 2 BEEPS

DONE

HOME INSTANT

MODE

START IN HOME MODE

HOLD DOWN

1 GONG & 2 BEEPS

DONE

22

Image 24
Contents Supervised Wireless Security Control Panel Introduction Linear LLCTable of Contents Dual 824 Security System Control PanelWireless Keypad Remote ControlsDOOR/WINDOW Sensors Panic ButtonsDesign the Installation Security System Floor PlanExample System Hardwired Keypad Three system supervisory indicatorsFive system mode indicators Overview of KeypadsHardwired Keypad Features Control Panel Features Terminals for hardwired loop inputsControl Panel Installation System LocationWall Mounting External AntennaHardwired Keypad Installation Hardwired Loop Wiring ARM/DISARM KEY Station WiringExternal Alarm Siren Connection Telephone Line ConnectionAutomation Output Connection Voice Response ModuleControl Panel Power Connection Backup Battery InstallationBasic Control Panel Programming Create the Master User CodeGong and four beeps will sound Program the Hardwired Loops Repeat Steps 3-6 to enable all of the hardwired loops usedProgram the Wireless Sensors Programming Different Sensor Types For All Models Basic Sensor Installation DXS-10 Wireless KeypadDXS-31 & DXS-32 DOOR/WINDOW Sensors Test SensorsCustomizing the Keypad Labeling the Sensor LocationsOFF Mode Chime ModeSystem Operating Modes Home Mode Lit sensor status indicators show which sensors are openHome Instant Mode Manual Bypassing of SensorsAway Mode Exit Delay For Leaving the PremisesTest Mode Sensor Operation in Each System ModeSensor Function Table Control Panel Power Power indicator normally glows when AC power is onWireless Sensor LOW Batteries System Trouble IndicationsCustomizing the System Adding Sensors to the SystemGong and fi ve Beeps will sound Removing Sensors from the SystemMaking a Sensor a 24-HOUR Door Chime Press HOME, 8, then AwayMaking a Sensor Interior Press HOME, 7, then AwayProgramming Information Sensor Operation in Each System Mode Making a Sensor Perform a Different FunctionSetup Mode Advanced ProgrammingControl Panel Programming Options Changing a Sensors Restore Requirements Entry Delay TimeExit Delay Time Changing a Sensors SupervisionRemote Control & Hardwire Arming Level Remote Control & Hardwire Disarming LevelEntry Delay Beeps Exit Delay BeepsSilent Burglary Alarms Silent Emergency AlarmsDisabling Quick Arming Automatic Restoral of Bypassed SensorsAutomation Output Mode During Alarm Remote Control & Hardwire ARM/DISARM ChirpAutomation Output on During and After Alarm Automation Output on During AlarmAutomation Output During EXIT/ENTRY Delays Remote Access PasswordAutomation Output While Armed Automation Output PolarityControl Panel Master Reset Adding Additional User CodesRemoving Additional User Codes Communicator Programming General Communicator OptionsCommunicator Enable Way manual, 3 2-way full duplex using this stepWAY Audio Voice ResponseDialing Delay Call LimiterDialing Method Reporting Format Call RoutingTelephone Number Delays and Special Characters Account NumberPrimary Telephone Number Secondary Telephone NumberReport Control Panel Trouble Report Force ArmingOpening and Closing Reports Point ID ReportingGeneral Reporting Codes Steps #201-206System Reporting Codes Fire and Emergency buttons and for eachSteps #261-266 Force Arming Reporting CodeBy 2 Format Point ID Alarm Report Codes Steps #210-233By 2 Format Point ID Trouble Report Codes Steps #234-257By 2 Format Point ID Reporting Codes Important Information