ADDING ADDITIONAL USER CODES
✦The Control Panel can be programmed with five restricted user codes and one page alert user code.
✦The restricted user codes operate the system as usual, but cannot access Setup Mode.
✦The restricted user codes can access a special Code Mode that can be used to change or remove any of the five restricted user codes, the page alert user code, or the duress code.
✦The page alert user code dials the supervisory number (programmed for a pager) when it is used to arm or disarm the system.
✦A restricted user code is appropriate to give any user that should be restricted from programming the Control Panel.
✎NOTE: For maximum security, a
✎WARNING: NEVER PROGRAM ANY RESTRICTED USER CODETHE SAME ASTHE MASTER USER CODE!
PROGRAMMING STEP
ENTERS STEP NUMBER
(3-5 DIGITS RECOMMENDED)
STORES CODE - 1 BING
STEP | CODE FUNCTION | CODE ENTERED |
STEP #93 | RESTRICTED USER CODE #1 |
|
|
|
|
STEP #94 | RESTRICTED USER CODE #2 |
|
|
|
|
STEP #95 | RESTRICTED USER CODE #3 |
|
|
|
|
STEP #96 | RESTRICTED USER CODE #4 |
|
|
|
|
STEP #97 | RESTRICTED USER CODE #5 |
|
|
|
|
STEP #98 | PAGE ALERT USER CODE |
|
|
|
|
STEPS
REMOVING ADDITIONAL USER CODES
STEPS |
| |
ENTER FOR STEP # | ||
from the Control Panel by entering the | ||
93 = RESTRICTED CODE 1 | ||
appropriate step number and pressing TEST. | ||
94 = RESTRICTED CODE 2 | ||
✦ Because access to programming would be | 95 = RESTRICTED CODE 3 | |
96 = RESTRICTED CODE 4 | ||
impossible without a master user code, it cannot be | ||
97 = RESTRICTED CODE 5 | ||
removed using these steps. The master user code | 98 = PAGE ALERT USER CODE | |
can be changed using programming STEP #99. |
| |
✎ NOTE: The master user code can be set to the | PROGRAMMING STEP | |
factory default using the Control Panel master | ||
| ||
reset programming step, although all other system |
| |
programming will be reset to factory values and all | REMOVES CODE - 1 BING | |
sensors programmed will be erased. |
|
CONTROL PANEL MASTER RESET
✦Master resetting the Control Panel will set all of the programming options back to the factory values. The master user code will be reset to 1234.
✎CAUTION: Master resetting the Control Panel will erase the user codes and remove all programmed sensors. All Control Panel and communicator programming values will be reset to the factory defaults.
1.Start with the system in Test Mode (Setup Mode cannot be reached from any other mode).
2.From Test Mode, enter the master user code then press TEST.
✴A “Gong” and fi ve “Beeps” will sound, signaling that the system is in Setup Mode.
3.Enter programming STEP #999 then press TEST.
4.Enter 999 again then press TEST again.
✴A “Bing” will sound to indicate the beginning of the reset process. This process will take up to 10 seconds while the memory is being reset.
✦The system will revert to the first time power- up condition and the new master user code will be 1234. Go to the “Basic Control Panel Programming” section of this manual to begin re- programming the system.
START IN TEST
MASTER USER CODE
ENTERS TEST MODE 1 GONG & 5 BEEPS
STEP #999
FOR MASTER
RESET
ENTERS STEP NUMBER
ENTER 999 TO OK
THE MASTER RESET
PRESS TEST, 1 BING SOUNDS,
WAIT ABOUT 10 SECONDS
DONE
USE THESE EXACT KEYSTROKES
TO PERFORM A MASTER RESET
35