AUTOMATION OUTPUT MODE DURING ALARM |
|
| |
|
| ||
✦ The factory setting causes the Automation | PROGRAMMING STEP #68 |
| |
Output to flash if it is programmed to activate |
| ||
|
| ||
during or after an alarm. |
|
|
|
✎ NOTE: For the Automation Output to activate | ENTERS STEP NUMBER |
| |
during or after an alarm, that function must be | 0 FOR FLASHING OUTPUT |
| |
enabled with Programming Step 71 or 72. |
| ||
1 FOR STEADY OUTPUT |
| ||
STEP #68 The output can be programmed to be a steady |
| ||
STORES VALUE - 1 BING |
| ||
output using this step. |
|
| |
|
|
| |
|
|
|
|
AUTOMATION ACTIVATION TONE |
|
|
|
✦ The factory setting causes the keypad(s) to | PROGRAMMING STEP #69 |
| |
sound a “Bing” when the Automation Output is |
| ||
|
| ||
activated by pressing the | key, or when it's |
|
|
triggered with a | ENTERS STEP NUMBER |
| |
STEP #69 This sound can be silenced using this step. | 0 FOR BING TONE OFF |
| |
|
|
| |
|
| 1 FOR BING TONE ON |
|
|
| STORES VALUE - 1 BING |
|
|
|
|
|
|
|
|
|
REMOTE CONTROL & HARDWIRE ARM/DISARM CHIRP
✦When arming with the portable remote control or with a hardwired loop programmed as arm/ disarm (sensor Function #9), the factory setting causes the keypad(s) to “chirp” once when armed, twice when disarmed, and three times when arming with sensors bypassed.
STEP #70 These chirps can be silenced using this step.
✎NOTE: If these chirps are silenced, it is recommended to program the Automation Output to be active when the system is armed, so a light can be triggered displaying the arming status of the system.
PROGRAMMING STEP #70
ENTERS STEP NUMBER
0 FOR CHIRPS OFF
1 FOR CHIRPS ON
STORES VALUE - 1 BING
AUTOMATION OUTPUT ON DURING AND AFTER ALARM
✦The factory setting causes the Control Panel's
Automation Output to activate when pressing the key, or when it's triggered with a
STEP #71 The Control Panel can be programmed to activate the Automation Output during and after any alarms as well as when normally triggered using this step.
✎NOTE: The output will continue until the flashing sensor status lights are cleared.
PROGRAMMING STEP #71
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING & AFTER ALARM
STORES VALUE - 1 BING
AUTOMATION OUTPUT ON DURING ALARM
✦The factory setting causes the Control Panel's
Automation Output to activate when pressing the key, or when it's triggered with a
STEP #72 The Control Panel can be programmed to activate the Automation Output during alarms as well as when normally triggered using this step.
✎NOTE: The Automation Output can be programmed to flash or be steady during alarm, see Programming Step 68.
PROGRAMMING STEP #72
ENTERS STEP NUMBER
0 FOR STANDARD TRIGGER
1 FOR OUTPUT DURING ALARM
STORES VALUE - 1 BING