Kenmore 153.332870HA owner manual For Your Safety, What to do if YOU Smell GAS, Model Numbers

Page 1

Owners

Manual

FOR POTABLEWATER

HEATING ONLY

NOT SUITABLEFOR

SPACEHEATING

NOT FOR USE IN

MOBILE HOMES

MODEL NUMBERS:

153.332861 40 Gal. L.R

153.332870HA 40 Gal. High Altitude L.E

153.332880 50 Gal. L.R

153.332890HA 50 Gal. High Altitude L.E

153.332960 40 Gal.

153.332970HA 40 Gal. High Altitude

153.332980 50 Gal.

153.332990HA 50 Gal. High Altitude

THE ECONOMIZERTM6

POWER VENT

GAS WATER HEATER

Safety Instructions

Care

and Maintenance

Installation

• Troubleshooting

Operation

Parts

List

For Your Safety

AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER

WARNING: If the information in these instructions are not followed exactly, a fire or explosionmay result, causingproperty damage, personalinjury or death.

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions.

If you cannot reach your gas supplier, call the fire department

-Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Caution:

Read and Follow

All Safety Rules and

Operating Instructions

Before First Use of

This Product,

Save this Manual for Future Reference.

AWARNINGI

Improper installation, adjustment, alteration, service or maintenance can I cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer I to this manual for assistance or consult the local Sears Service Center or gas ut ty for further nformat on.

AWARNING

Flammable vapors may be drawn by air currents from other areas of the structure to this appliance.

AWARNING

READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER.

Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.

Printed in the U.S.A. 0304

www.sears.com

Part No. 184820_0OO

Image 1
Contents What to do if YOU Smell GAS For Your SafetyModel Numbers Awarningj Safety PrecautionsLwarning AwarningRious Bodily INJURY, or Property Damage Safety Precautions contdAwarning DcmgPn%aticaoe ContentsCustomer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsInstallations in Areas Where Flammable LIQ Installation Instructions contdFacts to Consider About the Location Combustion Air and Ventilation Facts to Consider About the Location contdVenting Clearances Property DamageInlet Venting Through Roof- ClearancesInches Top and one commencing Within 12 inches From Installation Completed Installation InstructionsContd Water PipingII \ PROVIDEA6AIR \ GAP Between Temperature-Pressure Relief ValveUSE Without Power Cord WiringFilling the Water Heater Water Heaters Equipped for ONE Type VoltageUSE Without Power Cord contd Wiring contdWiring Diagram Warn I NGpre VentingVenting Through AN Outside Wall ALL Models ALL Models Optional 2VENT Piping Venting System Example Installations for ALL ModelsPVC, ABS or Cpvc Schedule 40 vent piping MAX. Length Elbows DIA.VENTII0 DIA.VENT Number of 90 DEG MAX. Length FT ElbowsDIA.VENT Number of 90 DEG PrecautionsDIA.VENT Number MAX. Length FT ElbowsJoints Approximate Setting Time For 2 to 3 Pipe3PVC, ABS or Cpvc Schedule 40 vent piping Venting Through a Roof ALL ModelsALL Models Optional 2 Vent Piping Gas Piping Gas Piping contd GAS Piping with Flexible ConnectorSediment Trap GAS Piping with ALL Black Iron Pipe To GAS ControlCheck for Leaks Installation ChecklistModel Rating Plate Before OperatingBefore the Water Heater will Operate Operating InstructionsOperation Before Operating Propane L.P. GAS Operating Instructions contdControl Sequence HOT Surface Direct Ignition Check for LeaksWith an ignition device which automatically Contd Temperature RegulationTank Sediment Cleaning Service and AdjustmentBurner Cleaning Venting System InspectionDrain Valve Washer Replacement Temperature-Pressure ReliefDraining TEM Peratu RE-PRESSURE Discharge PipeStart Up Conditions Troubleshooting GuideThermal Expansion Strange SoundsCondensation Troubleshooting Guide contdSMOKE/ODOR AIR in HOT Water FaucetsHigh Temperature Limit Switch Venting Manual Reset SwitchOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Systems Check Error in the hot surface ignitorcircuitCondensation Water Leaks Leaking T&P HOT Water Odors ¢Te= Blower will not runPage Parts Order List Economizer TM 6 Power Vent GAS Water Heater Model NumbersKEY NO. Part Description Parts Order List contdParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Master Protection Agreements Sears Installation Service