Kenmore 153.33298, 153.33296, 153.332870HA, 153.332861 With an ignition device which automatically

Page 28

Operating Instructions (cont'd)

 

explosion may result causing property damage, personal injury or

 

 

_[,_WARNING:lfyoudonotfollowtheseinstructionsexactiy,

 

afireor_

 

 

 

loss

of life.

 

 

 

 

 

 

 

BEFORE OPERATING: ENTIRE SYSTEM MUST BE FILLED WITH WATERAND AIR PURGED FROM ALL LINES.

A. This appliance does not have a pilot.

It is equipped

If you cannot

reach your gas supplier,

call the

fire

with an ignition device which automatically

lights the

department.

 

 

 

burner. Do NOT try to light the

burner by

hand.

C. Use only your

hand to push in the gas

control

but-

B. BEFORE

OPERATING

smell

all

around the

tons. Never use tools. If the control buttons will not

appliance

area for gas.

Be sure to smell next to the

push in, don'ttry to repair them, call a qualified

ser-

floor because some gas is heavier than air and will

vice technician.

Force or

attempted

repair

may

settle on the floor.

 

result in a fire or

explosion.

 

 

 

 

 

WHAT TO DO IF YOU SMELL GAS:

D. Do not use

this

appliance

if any

part

has

been

Do not try to light any appliance.

under water.

Immediately

call a qualified

service

Do not touch any electric switch;

technician to

inspect

the appliance

and to

replace

do not use any phone in your building.

any part of the control

system and

any gas

control

Immediately call your

gas supplier from a neighbor's

which has been under

water.

 

 

 

 

phone. Follow the gas

supplier's instructions.

 

 

 

 

 

 

 

 

 

.......7

A

IJ

Ovem

WARUO O

O

O

O

O ,O

......e

e

......

i

 

 

 

i

1. I_STOP!

Read the safety information above

_,#'on

this label.

2.Set the ON/OFF switch on the control box to the "ON" position.

3.Set the thermostat to_e lowest setting b_rst press- ing the COOLER _ and HOTTER _ buttons

together and holdi.J_ for 1 second. Then press the COOLER button £_) until the WARM indicator light

appears.

4.Set the ON/OFF switch on the control box to the "OFF" position.

1.Set thermostat,_to the lowest settin_ by first pressing the COOLER _ and HOTTER _ buttons together and holding for 1 second. Then press the COOLER button (_ until the WARM indicator light appears.

5.This appliance is equipped with a device which auto- matically lights the burner.

DO NOT TRY TO UGHT THE BURNER BY HAND.

6. Wait five (5) minutes

to

if_

clear

out any gas.

If you then smell gas,

 

_

STOP!

Follow "B" in

the safety

information

above on this label. If you

don'tsmell

gas, go to the next step.

 

7.Turn on all electrical power to the appliance.

8.Set the ON/OFF switch on the control box to the "ON" position.

9.Set the thermo_t to desired setl_ by first pressing the COOLER k_)and HOTTER t,_,'buttons together

and hol_g for 1 second. Then press the HOTTER button _.

10.WATER TEMPERATURE ADJUSTMENT • is approximately 120°E

_

CAUTION: Hotter water

increases the risk

 

of scald

injury. Consult

the instruction

 

manual

before changing

temperature.

11, if the appliance will not operate, follow the instruc- tions "TO TURN OFF GAS TO APPLIANCE" and call your technician or gas supplier.

,_ WARNING:BEFORETURNPOWERSERVICINGOFFALLELECTRIC

2.Set the ON/OFF switch on the control box to the "OFF" position.

3.Turn off all electric power to the appliance if service is to be performed.

28

Image 28
Contents What to do if YOU Smell GAS For Your SafetyModel Numbers Safety Precautions AwarningjLwarning AwarningSafety Precautions contd Rious Bodily INJURY, or Property DamageAwarning Contents DcmgPn%aticaoeProduct Specifications Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededMaterials Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterInstallations in Areas Where Flammable LIQ Installation Instructions contdFacts to Consider About the Location Facts to Consider About the Location contd Combustion Air and VentilationVenting Clearances Property DamageVenting Through Roof- Clearances InletInches Top and one commencing Within 12 inches From Installation Instructions Installation CompletedContd Water PipingTemperature-Pressure Relief Valve II \ PROVIDEA6AIR \ GAP BetweenWiring USE Without Power CordFilling the Water Heater Water Heaters Equipped for ONE Type VoltageUSE Without Power Cord contd Wiring contdWiring Diagram Warn I NGpre VentingVenting Through AN Outside Wall ALL Models ALL Models Optional 2VENT Piping Venting System Example Installations for ALL ModelsPVC, ABS or Cpvc Schedule 40 vent piping DIA.VENT MAX. Length ElbowsII0 DIA.VENT Number of 90 DEG MAX. Length FT ElbowsPrecautions DIA.VENT Number of 90 DEGDIA.VENT Number MAX. Length FT ElbowsApproximate Setting Time For 2 to 3 Pipe Joints3PVC, ABS or Cpvc Schedule 40 vent piping Venting Through a Roof ALL ModelsALL Models Optional 2 Vent Piping Gas Piping GAS Piping with Flexible Connector Gas Piping contdSediment Trap GAS Piping with ALL Black Iron Pipe To GAS ControlInstallation Checklist Check for LeaksModel Rating Plate Before OperatingBefore the Water Heater will Operate Operating InstructionsOperation Operating Instructions contd Before Operating Propane L.P. GASControl Sequence HOT Surface Direct Ignition Check for LeaksWith an ignition device which automatically Temperature Regulation ContdService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionTemperature-Pressure Relief Drain Valve Washer ReplacementDraining TEM Peratu RE-PRESSURE Discharge PipeTroubleshooting Guide Start Up ConditionsThermal Expansion Strange SoundsTroubleshooting Guide contd CondensationSMOKE/ODOR AIR in HOT Water FaucetsVenting Manual Reset Switch High Temperature Limit SwitchOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Error in the hot surface ignitorcircuit Systems Check¢Te= Blower will not run Condensation Water Leaks Leaking T&P HOT Water OdorsPage Economizer TM 6 Power Vent GAS Water Heater Model Numbers Parts Order ListParts Order List contd KEY NO. Part DescriptionParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Sears Installation Service Master Protection Agreements