Venting

_WARNING

To insure proper venting of this gas-fired water heater, the correct vent pipe diameter must be uti- lized. Any additions of other gas appliances on vent

with this water heater will adversely affect the oper- ation of the water heater.

The combustion alld ventilation air flow must not be obstructed.

AWARNING

The power vent water heater requires its own (sepa- rate) venting system. It cannot be connected to an ex-

isting vent pipe or chimney. It must be terminated to the outdoors. Failure to properly install the venting sys-

tem can result in asphyxiation, a fire or explosion and

can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

Obstructed or deteriorated vent systems may

WARN I NGpre-

sent a serious health risk or asphyxiation.

The vent pipe from the water heater must

_, WARN I NGslope upward % inch per five linear feet.

&WARNING

Chemical vapor corrosion of the flue and vent sys- tem may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning sol-

vents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chlo- ride, waxes, bleach, and process chemicals are typi- cal compounds which are potentially corrosive.

\

STRAPPING

Horizontal runs must be securely supported at 3V2foot intervals and vertical runs supported at 5 foot intervals.

VENTING THROUGH AN OUTSIDE WALL

ALL MODELS

3" PVC, ABS or CPVC Schedule 40 vent piping:

MI vent gases must be completely vented to the outdoors of the

structure (dwelling).

MIN. RISE½'

PERFIVEFEET

AWARNINGI

Failure to have required clearances between water I

heater and combustible material will result in a fire hazard.

&WARNINGI

Be sure vent pipe is properly connected to prevent I

escape of dangerous flue gases which could cause

dead y asphyx at on.

1.A Y" PVC Schedule 40-45 ° vent cap with wire screen is sup- plied with the water heater.

2.A 3 I VC, ABS or CPVC Schedule 40-90 ° street ell; used to

connect the vent pipe to the water heater when the vent pipe is to be turned horizontally directly off" the blower (supplied

locally).

3.3 _tVC, ABS or CPVC Schedule 40 pipe (must be supplied locally).

3" PVC,ABS OR CPVC

SCHEDULE

4ogOOELOOWt

3" PVC,ABSOR CPVC

SCHEDULE40 PiPE VENTCAP

SCREEN

WITH

The water heater requires its own (separate) venting system.

3 I VC, ABS or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system on all models.

It cannot be connected to existing vent piping or chimney.

It must terminate horizontally to the outdoors.

17

Image 17
Contents Model Numbers For Your SafetyWhat to do if YOU Smell GAS Awarningj Safety PrecautionsLwarning AwarningRious Bodily INJURY, or Property Damage Safety Precautions contdAwarning DcmgPn%aticaoe ContentsCustomer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsFacts to Consider About the Location Installation Instructions contdInstallations in Areas Where Flammable LIQ Combustion Air and Ventilation Facts to Consider About the Location contdVenting Clearances Property DamageInlet Venting Through Roof- ClearancesInches Top and one commencing Within 12 inches From Installation Completed Installation InstructionsContd Water PipingII \ PROVIDEA6AIR \ GAP Between Temperature-Pressure Relief ValveUSE Without Power Cord WiringFilling the Water Heater Water Heaters Equipped for ONE Type VoltageWiring Diagram Wiring contdUSE Without Power Cord contd Venting Through AN Outside Wall ALL Models VentingWarn I NGpre PVC, ABS or Cpvc Schedule 40 vent piping Venting System Example Installations for ALL ModelsALL Models Optional 2VENT Piping MAX. Length Elbows DIA.VENTII0 DIA.VENT Number of 90 DEG MAX. Length FT ElbowsDIA.VENT Number of 90 DEG PrecautionsDIA.VENT Number MAX. Length FT ElbowsJoints Approximate Setting Time For 2 to 3 PipeALL Models Optional 2 Vent Piping Venting Through a Roof ALL Models3PVC, ABS or Cpvc Schedule 40 vent piping Gas Piping Gas Piping contd GAS Piping with Flexible ConnectorSediment Trap GAS Piping with ALL Black Iron Pipe To GAS ControlCheck for Leaks Installation ChecklistModel Rating Plate Before OperatingOperation Operating InstructionsBefore the Water Heater will Operate Before Operating Propane L.P. GAS Operating Instructions contdControl Sequence HOT Surface Direct Ignition Check for LeaksWith an ignition device which automatically Contd Temperature RegulationTank Sediment Cleaning Service and AdjustmentBurner Cleaning Venting System InspectionDrain Valve Washer Replacement Temperature-Pressure ReliefDraining TEM Peratu RE-PRESSURE Discharge PipeStart Up Conditions Troubleshooting GuideThermal Expansion Strange SoundsCondensation Troubleshooting Guide contdSMOKE/ODOR AIR in HOT Water FaucetsHigh Temperature Limit Switch Venting Manual Reset SwitchOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Systems Check Error in the hot surface ignitorcircuitCondensation Water Leaks Leaking T&P HOT Water Odors ¢Te= Blower will not runPage Parts Order List Economizer TM 6 Power Vent GAS Water Heater Model NumbersKEY NO. Part Description Parts Order List contdParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Master Protection Agreements Sears Installation Service