Kenmore 153.332990HA Facts to Consider About the Location contd, Combustion Air and Ventilation

Page 10

Installation Instructions (cont'd)

Facts to Consider About the Location (cont'd)

AWARNING

This water heater must not be installeddirectly on carpeting. Carpeting must be protected by a metal or wood panel beneaththe applianceextendingbeyond the full width and depth of the applianceby at least 3 inches(76.2mm) in an) direction,or if the applianceisinstalledin an alcoveor closet the entire floor must be coveredby the panel. Failureto hee¢ this warningmay result in a fire hazard.

Combustion Air and Ventilation

When determining the installation location for a power vent water heater, snow accumulation and drifting should be consid- ered in areas where applicable.

VENTING CLEARANCES

0" clearance for 3" (and optional 2") PVC, ABS or CPVC Schedule 40 vent piping from combustible surfaces.

12" minimum from the ground, 9" ceiling overhangs. Figure 2.

The Power Vent outlet terminal shall terminate at least 36" above any forced air inlet located within 10 feet. Figure 3a.

&WARNING

Minimum clearances between the water heater and com- bustible construction are 0" at the sides and rear, 5" at the front, and 0" from the vent pipe. Clearance from the top of the jacket is 12". Provide 24 inches front clearance for servic- ing and adequate clearance between the jacket top & ceiling for servicing the flue area. (See Figure I). Refer to the label on the water heater adjacent to the gas control valve for all clearances.

12" MAX

V N[(A[((}N

AIR

)_ NIN 3_

 

TOPVIEW

-[_" MIN.

OF CL{}SET

.')_ ViEW

WTI OUT DOOR

OF (lOSE[

_2" MAX.

WI]H D{){>}i

Figure I ]

AIR [>LCI

_, WARNING

A gas water heater cannot operate properly without the cor- rect amount of air for combustion. Do not install in a con-

fined area such a closet, unless you provide air as shown in the "Facts to Consider About the Location" section. Never

obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas company. Failure to provide the proper amount of combustion air can result in a fire or explo-

sion and can cause DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.

_,WARNING

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries

with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combus-

tion and ventilation air be taken from outside these areas. Refer to the "Facts to Consider About the Location" sec- tion of this manual and also the current edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concerning air required.

The Power Vent outlet terminal shall terminate at least 4 feet

below, 4 feet horizontally from or 1 foot above any door, win- dow or gravity air inlet into the building. Figure 3a.

18" minimum in all directions from any obstruction that may interf?re. Figure 3b.

18" minimum from other natural draft (gravity) direct vent,

power vent or power direct vent appliance inlet and/or outlet vent(s) when directly above or 135° to either side of center line.

Figure 3c

a24" minimum from any appliance inlet and/or outlet vents when directly below or 45 ° to either side of center line. Figure 3c.

The location selection must provide clearances for servicing and proper operation of the water heater. Figure 4.

Vent termination must not be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment.

The venting system must be installed in a manner which allows inspection of the installation of the venting pipes and joints as well as periodic inspection after installation as required by ANSI Standards.

&WARNINGJ

Vent termination must not be within 4 feet of any items such as

gas meters, gas valves or other gas regulating equipment.

Failureto haverequired clearancesbetweenwater

& WARNINGheater and

combustiblematerialwill result in a fire hazard.

Figure 2 1

10

Image 10
Contents What to do if YOU Smell GAS For Your SafetyModel Numbers Lwarning Safety PrecautionsAwarningj AwarningSafety Precautions contd Rious Bodily INJURY, or Property DamageAwarning Contents DcmgPn%aticaoeProduct Specifications Customer ResponsibilitiesMaterials Needed Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterInstallations in Areas Where Flammable LIQ Installation Instructions contdFacts to Consider About the Location Venting Clearances Facts to Consider About the Location contdCombustion Air and Ventilation Property DamageVenting Through Roof- Clearances InletInches Top and one commencing Within 12 inches From Contd Installation InstructionsInstallation Completed Water PipingTemperature-Pressure Relief Valve II \ PROVIDEA6AIR \ GAP BetweenFilling the Water Heater WiringUSE Without Power Cord Water Heaters Equipped for ONE Type VoltageUSE Without Power Cord contd Wiring contdWiring Diagram Warn I NGpre VentingVenting Through AN Outside Wall ALL Models ALL Models Optional 2VENT Piping Venting System Example Installations for ALL ModelsPVC, ABS or Cpvc Schedule 40 vent piping II0 DIA.VENTMAX. Length Elbows DIA.VENT Number of 90 DEG MAX. Length FT ElbowsDIA.VENT Number PrecautionsDIA.VENT Number of 90 DEG MAX. Length FT ElbowsApproximate Setting Time For 2 to 3 Pipe Joints3PVC, ABS or Cpvc Schedule 40 vent piping Venting Through a Roof ALL ModelsALL Models Optional 2 Vent Piping Gas Piping Sediment Trap GAS Piping with Flexible ConnectorGas Piping contd GAS Piping with ALL Black Iron Pipe To GAS ControlModel Rating Plate Installation ChecklistCheck for Leaks Before OperatingBefore the Water Heater will Operate Operating InstructionsOperation Control Sequence HOT Surface Direct Ignition Operating Instructions contdBefore Operating Propane L.P. GAS Check for LeaksWith an ignition device which automatically Temperature Regulation ContdBurner Cleaning Service and AdjustmentTank Sediment Cleaning Venting System InspectionDraining Temperature-Pressure ReliefDrain Valve Washer Replacement TEM Peratu RE-PRESSURE Discharge PipeThermal Expansion Troubleshooting GuideStart Up Conditions Strange SoundsSMOKE/ODOR Troubleshooting Guide contdCondensation AIR in HOT Water FaucetsOperational Conditions contd Venting Manual Reset SwitchHigh Temperature Limit Switch Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Error in the hot surface ignitorcircuit Systems Check¢Te= Blower will not run Condensation Water Leaks Leaking T&P HOT Water OdorsPage Economizer TM 6 Power Vent GAS Water Heater Model Numbers Parts Order ListParts Order List contd KEY NO. Part DescriptionParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Sears Installation Service Master Protection Agreements