Kenmore 153.332861, 153.33296, 153.332870HA, 153.332990HA Dia.Vent, MAX. Length Elbows, II0

Page 19

Installation Instructions (cont'd)

3

ELBOW

EXAMPLE

MIN. RISEY¢'

PER FIVEFEET

MIN. RISEY;"

PER FIVEFEET

ALL MODELS (3" VENT)

See tables for max. length.

4'MiN.

157;'MIN.

14"MIN.

MIN, RISE¼"

 

 

PERFIVEFEET

1.The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90 ° elbows as specified in the following tables. If more elbows are required, the vent- ing distance must be reduced 5 feet for every 90 ° elbow:

ALL MODELS-

VENTING

THROUGH

WALL

3" DIA.VENT

 

NUMBER

OF 90 ° DEG.

MAX. LENGTH

(FT.)

ELBOWS*

115

 

 

I

II0

 

 

2

105

 

 

3

100

 

 

4

95

 

 

5

9O

 

 

6

ALL MODELS- VENTING THROUGH WALL

OPTIONAL 2°" VENT PIPING

2" DIA.VENT

NUMBER OF 90 ° DEG.

MAX. LENGTH (FT.)

ELBOWS*

5O

I

45

2

4O

3

35

4

3O

5

25

6

*NOTE: Two 45 ° elbows are equivalent to one 90 ° elbow. One 90 ° elbow equals 5 feet of equivalent vent length.

_S'MAX.

MIN. RISEY;"

PERFIVE FEET

20'

ONE ELBOW

(EXAMPLE)

EXAMPLE

 

_l_ 3" VENT PIPE

EXAMPLE USING ONE ELBOW

WITH 3" VENT PIPE

2. Minimum vent length Gr all models is 4 feet.

19

Image 19
Contents What to do if YOU Smell GAS For Your SafetyModel Numbers Awarning Safety PrecautionsAwarningj LwarningRious Bodily INJURY, or Property Damage Safety Precautions contdAwarning DcmgPn%aticaoe ContentsCustomer Responsibilities Product SpecificationsBasic Tools Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Materials NeededRemoving the Old Water Heater Installation InstructionsInstallations in Areas Where Flammable LIQ Installation Instructions contdFacts to Consider About the Location Property Damage Facts to Consider About the Location contdCombustion Air and Ventilation Venting ClearancesInlet Venting Through Roof- ClearancesInches Top and one commencing Within 12 inches From Water Piping Installation InstructionsInstallation Completed ContdII \ PROVIDEA6AIR \ GAP Between Temperature-Pressure Relief ValveWater Heaters Equipped for ONE Type Voltage WiringUSE Without Power Cord Filling the Water HeaterUSE Without Power Cord contd Wiring contdWiring Diagram Warn I NGpre VentingVenting Through AN Outside Wall ALL Models ALL Models Optional 2VENT Piping Venting System Example Installations for ALL ModelsPVC, ABS or Cpvc Schedule 40 vent piping DIA.VENT Number of 90 DEG MAX. Length FT Elbows DIA.VENTMAX. Length Elbows II0MAX. Length FT Elbows PrecautionsDIA.VENT Number of 90 DEG DIA.VENT NumberJoints Approximate Setting Time For 2 to 3 Pipe3PVC, ABS or Cpvc Schedule 40 vent piping Venting Through a Roof ALL ModelsALL Models Optional 2 Vent Piping Gas Piping GAS Piping with ALL Black Iron Pipe To GAS Control GAS Piping with Flexible ConnectorGas Piping contd Sediment TrapBefore Operating Installation ChecklistCheck for Leaks Model Rating PlateBefore the Water Heater will Operate Operating InstructionsOperation Check for Leaks Operating Instructions contdBefore Operating Propane L.P. GAS Control Sequence HOT Surface Direct IgnitionWith an ignition device which automatically Contd Temperature RegulationVenting System Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningTEM Peratu RE-PRESSURE Discharge Pipe Temperature-Pressure ReliefDrain Valve Washer Replacement DrainingStrange Sounds Troubleshooting GuideStart Up Conditions Thermal ExpansionAIR in HOT Water Faucets Troubleshooting Guide contdCondensation SMOKE/ODORNot Enough or no HOT Water Venting Manual Reset SwitchHigh Temperature Limit Switch Operational Conditions contdLeakage Checkpoints Thermostat and GAS Supply Check Systems Check Error in the hot surface ignitorcircuitCondensation Water Leaks Leaking T&P HOT Water Odors ¢Te= Blower will not runPage Parts Order List Economizer TM 6 Power Vent GAS Water Heater Model NumbersKEY NO. Part Description Parts Order List contdParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Master Protection Agreements Sears Installation Service