Kenmore 153.332870HA Installation Instructions contd, Facts to Consider About the Location

Page 9

Installation Instructions (cont'd)

Facts to Consider About the Location

You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most

economical use of the appliance. This water heater is not for use in mobile homes or outdoor installation.

Whether replacing an old water heater or putting the water

heater in a new location, the following critical points must be observed.

1.The location selected should be indoors as close as practical to the vent termination point, and as centralized with the water piping system as possible. The water heater, as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage.

2.ALL MODELS - If vented through an outside wall or through the roof, the 3" vent piping cannot exceed a total of

115 feet (50 feet if optional 2" vent piping is used), including vertical and horizontal runs with one 90 ° elbow. If more

elbows are required, the venting distance must be reduced 5

feet for every 90 ° elbow. See pages 19, 20 and 23 for vent charts.

3.Vent piping cannot slope downward and horizontal runs require a minimum V_"rise per five feet. All horizontal runs require adequate support at 3½ foot intervals and vertical runs supported at 5 foot intervals.

4.The water heater requires its own (separate) venting system. It cannot be connected to an existing vent pipe or chimney. It must terminate to the outdoors. Whenever possible termi- nate the vent on the leaward side of the building if vented

through an outside wall. NOTE: Condensation may be cre-

ated, at times, as the combustion gases exit the vent cap

and discoloration of surfaces in proximity to the vent cap may occur.

_,WARNING

The power vent water heater requires its own (separate) vent- ing system. It cannot be connected to an existing vent pipe or chimney. It must be terminated to the outdoors. Failure to properly install the venting system can result in asphyxiation, a fire or explosion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

5.The water heater comes equipped with a 7 foot power cord

which can be used to connect to a 110/120 volt power

source if (1) local codes allow, and (2) there is a three prong receptacle available.

CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the

water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will

not cause damage to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Such a drain pan must be not greater than 1'/2inches deep, have a minimum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow.

6.The location selection must provide adequate clearances for servicing and proper operation of the water heater.

_WARNING

INSTALLATIONS IN AREAS WHERE FLAMMABLE LIQ-

UIDS (VAPORS) ARE LIKELY TO BE PRESENT OR STORED (GARAGES, STORAGE, AND UTILITY AREAS, ETC): Flammable liquids (such as gasoline, solvents, propane (LP) or butane, etc.), all of which emit flammable vapors, may be improperly stored or used in such areas. The gas water heater ignitor or main burner can ignite such vapors. The resulting flashback and fire can cause death or serious burns to anyone in the area, as well as property damage.

If installation in such areas is your only option, then the instal-

lation must be accomplished in a way that the ignitor and main burner flame are elevated from the floor at least 18 inches.

While this may reduce the chances of flammable vapors from

a floor spill being ignited, gasoline and other flammable sub- stances should never be stored or used in the same room or

area containing a gas water heater or other open flame or spark producing appliance.

Also, the water heater must be located andlor protected so it is not subject to physical damage by a moving vehicle.

NOTE: Flammable vapors may be drawn by air currents from other areas of the structure to the appliance.

&WARNING

Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.

&WARNINGI

Do not use an extension cord. If there is not a suitable recep- tacle and/or local codes prohibit use of a power cord, field

w r ng must be prov ded.

9

Image 9
Contents For Your Safety What to do if YOU Smell GASModel Numbers Awarningj Safety PrecautionsLwarning AwarningRious Bodily INJURY, or Property Damage Safety Precautions contdAwarning DcmgPn%aticaoe ContentsCustomer Responsibilities Product SpecificationsMaterials and Basic Tools Needed Additional Tools Needed When Sweat SolderingMaterials Needed Basic ToolsRemoving the Old Water Heater Installation InstructionsInstallation Instructions contd Installations in Areas Where Flammable LIQFacts to Consider About the Location Combustion Air and Ventilation Facts to Consider About the Location contdVenting Clearances Property DamageInlet Venting Through Roof- ClearancesInches Top and one commencing Within 12 inches From Installation Completed Installation InstructionsContd Water PipingII \ PROVIDEA6AIR \ GAP Between Temperature-Pressure Relief ValveUSE Without Power Cord WiringFilling the Water Heater Water Heaters Equipped for ONE Type VoltageWiring contd USE Without Power Cord contdWiring Diagram Venting Warn I NGpreVenting Through AN Outside Wall ALL Models Venting System Example Installations for ALL Models ALL Models Optional 2VENT PipingPVC, ABS or Cpvc Schedule 40 vent piping MAX. Length Elbows DIA.VENTII0 DIA.VENT Number of 90 DEG MAX. Length FT ElbowsDIA.VENT Number of 90 DEG PrecautionsDIA.VENT Number MAX. Length FT ElbowsJoints Approximate Setting Time For 2 to 3 PipeVenting Through a Roof ALL Models 3PVC, ABS or Cpvc Schedule 40 vent pipingALL Models Optional 2 Vent Piping Gas Piping Gas Piping contd GAS Piping with Flexible ConnectorSediment Trap GAS Piping with ALL Black Iron Pipe To GAS ControlCheck for Leaks Installation ChecklistModel Rating Plate Before OperatingOperating Instructions Before the Water Heater will OperateOperation Before Operating Propane L.P. GAS Operating Instructions contdControl Sequence HOT Surface Direct Ignition Check for LeaksWith an ignition device which automatically Contd Temperature RegulationTank Sediment Cleaning Service and AdjustmentBurner Cleaning Venting System InspectionDrain Valve Washer Replacement Temperature-Pressure ReliefDraining TEM Peratu RE-PRESSURE Discharge PipeStart Up Conditions Troubleshooting GuideThermal Expansion Strange SoundsCondensation Troubleshooting Guide contdSMOKE/ODOR AIR in HOT Water FaucetsHigh Temperature Limit Switch Venting Manual Reset SwitchOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Systems Check Error in the hot surface ignitorcircuitCondensation Water Leaks Leaking T&P HOT Water Odors ¢Te= Blower will not runPage Parts Order List Economizer TM 6 Power Vent GAS Water Heater Model NumbersKEY NO. Part Description Parts Order List contdParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Master Protection Agreements Sears Installation Service