Kenmore 153.332990HA, 153.33296, 153.332870HA, 153.332861, 153.33298, 153.332890HA Parts Order List

Page 42

Parts Order List

THE ECONOMIZER TM 6 POWER VENT GAS WATER HEATER MODEL NUMBERS:

153.332960 40 Gal.

153.332970HA 40 Gal. High Altitude

153.332980 50 Gal.

153.332990HA 50 Gal. High Altitude

28

PVC, ABS or CPVC Items for all models supplied locally

278

I

 

27

 

25d

 

 

24

 

b

7

8

 

 

9

 

22_

lr_:j

10

2o

14 _15

19_16_

42

Image 42
Contents For Your Safety What to do if YOU Smell GASModel Numbers Lwarning Safety PrecautionsAwarningj AwarningSafety Precautions contd Rious Bodily INJURY, or Property DamageAwarning Contents DcmgPn%aticaoeProduct Specifications Customer ResponsibilitiesMaterials Needed Additional Tools Needed When Sweat SolderingMaterials and Basic Tools Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterInstallation Instructions contd Installations in Areas Where Flammable LIQFacts to Consider About the Location Venting Clearances Facts to Consider About the Location contdCombustion Air and Ventilation Property DamageVenting Through Roof- Clearances InletInches Top and one commencing Within 12 inches From Contd Installation InstructionsInstallation Completed Water PipingTemperature-Pressure Relief Valve II \ PROVIDEA6AIR \ GAP BetweenFilling the Water Heater WiringUSE Without Power Cord Water Heaters Equipped for ONE Type VoltageWiring contd USE Without Power Cord contdWiring Diagram Venting Warn I NGpreVenting Through AN Outside Wall ALL Models Venting System Example Installations for ALL Models ALL Models Optional 2VENT PipingPVC, ABS or Cpvc Schedule 40 vent piping II0 DIA.VENTMAX. Length Elbows DIA.VENT Number of 90 DEG MAX. Length FT ElbowsDIA.VENT Number PrecautionsDIA.VENT Number of 90 DEG MAX. Length FT ElbowsApproximate Setting Time For 2 to 3 Pipe JointsVenting Through a Roof ALL Models 3PVC, ABS or Cpvc Schedule 40 vent pipingALL Models Optional 2 Vent Piping Gas Piping Sediment Trap GAS Piping with Flexible ConnectorGas Piping contd GAS Piping with ALL Black Iron Pipe To GAS ControlModel Rating Plate Installation ChecklistCheck for Leaks Before OperatingOperating Instructions Before the Water Heater will OperateOperation Control Sequence HOT Surface Direct Ignition Operating Instructions contdBefore Operating Propane L.P. GAS Check for LeaksWith an ignition device which automatically Temperature Regulation ContdBurner Cleaning Service and AdjustmentTank Sediment Cleaning Venting System InspectionDraining Temperature-Pressure ReliefDrain Valve Washer Replacement TEM Peratu RE-PRESSURE Discharge PipeThermal Expansion Troubleshooting GuideStart Up Conditions Strange SoundsSMOKE/ODOR Troubleshooting Guide contdCondensation AIR in HOT Water FaucetsOperational Conditions contd Venting Manual Reset SwitchHigh Temperature Limit Switch Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Error in the hot surface ignitorcircuit Systems Check¢Te= Blower will not run Condensation Water Leaks Leaking T&P HOT Water OdorsPage Economizer TM 6 Power Vent GAS Water Heater Model Numbers Parts Order ListParts Order List contd KEY NO. Part DescriptionParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Sears Installation Service Master Protection Agreements