Kenmore 153.33298, 153.33296 DIA.VENT Number of 90 DEG, MAX. Length FT Elbows, Precautions

Page 20

Installation Instructions (cont'd)

Venting (cont'd)

VENTING THROUGH AN OUTSIDE WALL WITH

LOW GROUND CLEARANCE

1.When the vent piping cannot pass through an outside wall at a height greater than or equal to 12" above the ground (or above snow accumulation level), then the installation can be modified as shown below.

/,%

[//_,

/%

7[

MIN. ABOVE

>:_

I I GROUNDORSNOW

_

ACCiNULATION LEVEL

2.Refer to the tables below for maximum vent lengths for low ground clearance installations. All installations assume the use

of two additional 90 ° elbows and the standard 45 ° vent cap with screen outside of the exterior wall.

ALL MODELS -- LOW GROUND CLEARANCE

3" DIA.VENT

NUMBER OF 90 ° DEG.

MAX. LENGTH (FT.) ELBOWS* (inside bldg)

105I

1002

953

904

855

8O6

ALL MODELS -- LOW GROUND CLEARANCE

OPTIONAL 2" VENT PIPING

2" DIA.VENT

NUMBER

OF 90 ° DEG.

MAX. LENGTH (FT.)

ELBOWS*

(inside bldg)

4O

 

I

35

 

2

3O

 

3

25

 

4

2O

 

5

15

 

6

CEMENTING PVC, ABS OR CPVC PIPE AND

FITTINGS

Read and observe all safety information printed on primer, cleaner, and cement containers.

_. DANGERI Primer, cleaner, and cements are extremely I flammable. They are harmful or fatal if swallowed. The I vapors are harmful. They may irritate eyes and skin

and can be absorbed through the sk n.

_. PRECAUTIONS

Always store primers, cleaner, and cements in cool, dry, well ventilated places. Do not store them near

heat, sparks, or flames. Keep containers closed. Use them in well ventilated areas. Wear impervious cloth- ing while handling. Do not smoke, eat, or drink while handling. Wash thoroughly after handling and before eating. Wear eye protection when handling. If swal- lowed, drink water, do not induce vomiting, and call a physician or poison control center immediately. If inhaled, get fresh air and seek medical attention if ill feelings persist. In case of eye and skin contact, imme- diately flush with plenty of water for 15 minutes and

seek medical attention if irritation persists. KEEP OUT OR REACH OF CHILDREN.

All primers, cleaners, and cements must meet all local codes and applicable standards of the American Society For Testing Materials Standards.

Before using primers, cleaners, and cements, stir or shake, mak- ing sure contents are liquid. Do not use if found to be lumpy or jelly-like.

1.Cut pipe ends squarely removing all burrs and dirt.

2.Dry fit pipe and fittings to be connected for proper fit.

3.Clean pipe and fitting with a primer/cleaner.

4.Apply a thin coat of cement to fitting, avoiding puddling inside.

5.Apply a liberal coat of cement to pipe leaving no voids.

6.QUICKLY assemble parts while cement is flui!! If you wait too long, re-coat pipes.

7.Push pipe completely into socket of fitting, turning as it goes until it bottoms.

8.Hold pipe and fitting together for 30 seconds. Then carefully clean off"excess with a cloth. Allow connections a sufficient

time to cure before disturbing.

9.Remember that vent pipes must be adequately and securely supported.

*NOTE: Two 45 o elbows are equivalent to one 90 o elbow. One 90 ° elbow equals 5 feet of equivalent vent length.

2O

Image 20
Contents Model Numbers For Your SafetyWhat to do if YOU Smell GAS Safety Precautions AwarningjLwarning AwarningSafety Precautions contd Rious Bodily INJURY, or Property DamageAwarning Contents DcmgPn%aticaoeProduct Specifications Customer ResponsibilitiesAdditional Tools Needed When Sweat Soldering Materials and Basic Tools NeededMaterials Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterFacts to Consider About the Location Installation Instructions contdInstallations in Areas Where Flammable LIQ Facts to Consider About the Location contd Combustion Air and VentilationVenting Clearances Property DamageVenting Through Roof- Clearances InletInches Top and one commencing Within 12 inches From Installation Instructions Installation CompletedContd Water PipingTemperature-Pressure Relief Valve II \ PROVIDEA6AIR \ GAP BetweenWiring USE Without Power CordFilling the Water Heater Water Heaters Equipped for ONE Type VoltageWiring Diagram Wiring contdUSE Without Power Cord contd Venting Through AN Outside Wall ALL Models VentingWarn I NGpre PVC, ABS or Cpvc Schedule 40 vent piping Venting System Example Installations for ALL ModelsALL Models Optional 2VENT Piping DIA.VENT MAX. Length ElbowsII0 DIA.VENT Number of 90 DEG MAX. Length FT ElbowsPrecautions DIA.VENT Number of 90 DEGDIA.VENT Number MAX. Length FT ElbowsApproximate Setting Time For 2 to 3 Pipe JointsALL Models Optional 2 Vent Piping Venting Through a Roof ALL Models3PVC, ABS or Cpvc Schedule 40 vent piping Gas Piping GAS Piping with Flexible Connector Gas Piping contdSediment Trap GAS Piping with ALL Black Iron Pipe To GAS ControlInstallation Checklist Check for LeaksModel Rating Plate Before OperatingOperation Operating InstructionsBefore the Water Heater will Operate Operating Instructions contd Before Operating Propane L.P. GASControl Sequence HOT Surface Direct Ignition Check for LeaksWith an ignition device which automatically Temperature Regulation ContdService and Adjustment Tank Sediment CleaningBurner Cleaning Venting System InspectionTemperature-Pressure Relief Drain Valve Washer ReplacementDraining TEM Peratu RE-PRESSURE Discharge PipeTroubleshooting Guide Start Up ConditionsThermal Expansion Strange SoundsTroubleshooting Guide contd CondensationSMOKE/ODOR AIR in HOT Water FaucetsVenting Manual Reset Switch High Temperature Limit SwitchOperational Conditions contd Not Enough or no HOT WaterLeakage Checkpoints Thermostat and GAS Supply Check Error in the hot surface ignitorcircuit Systems Check¢Te= Blower will not run Condensation Water Leaks Leaking T&P HOT Water OdorsPage Economizer TM 6 Power Vent GAS Water Heater Model Numbers Parts Order ListParts Order List contd KEY NO. Part DescriptionParts Order List 153.332960 153.332970HA 153.332980 153.332990HA Sears Installation Service Master Protection Agreements