Cisco Systems IE301024TC manual Installing the Power-Supply Module in the Switch

Models: 3010 IE3010 IE301024TC

1 100
Download 100 pages 7.97 Kb
Page 56
Image 56
Installing the Power-Supply Module in the Switch

Chapter 3 Power Supply Installation

Power-Supply Module Installation

Figure 3-4 Crimping the Terminal Lug

280938

Step 4 Slide the ground screw from Step 1 through the terminal lug. Insert the ground screws into the opening on the cable side.

Figure 3-5 Attaching the Terminal Lug

208335

1

Dual-hole terminal lug

Step 5 Use a ratcheting torque screwdriver to tighten the ground screws to 30 in-lb (± 2 in-lb).

Step 6 Attach the other end of the ground wire to a grounded bare metal surface, such as a ground bus or a grounded bare rack.

Installing the Power-Supply Module in the Switch

Step 1 We recommend that power be off at the AC or DC circuits. Locate the circuit breakers, turn them OFF, and tape them in the OFF position.

Note If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.

Step 2 Use a Phillips screwdriver to loosen the two captive screws of the blank power-supply module and gently pull it out. See Figure 3-6and Figure 3-7.

Cisco IE 3010 Switch Hardware Installation Guide

3-6

78-19581-02

 

 

Page 56