P74290ea_F1DExxxC_man.qxd 30-10-2003 11:20 Page 14

INSTALLATION

DIP Switch Configuration Chart

 

N° DU COMMUTATEUR DIP

 

ADRESSE BANK

1

2

3

 

4

 

 

 

 

 

 

 

 

 

BAS

 

BAS

BAS

 

BAS

BANK 00 (valeur par défaut)

 

 

 

 

 

 

 

HAUT

 

BAS

BAS

 

BAS

BANK 01 PRIMAIRE/SECONDAIRE

 

 

 

 

 

 

 

BAS

 

HAUT

BAS

 

BAS

BANK 02 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

HAUT

BAS

 

BAS

BANK 03 SECONDAIRE

 

 

 

 

 

 

 

BAS

 

BAS

HAUT

 

BAS

BANK 04 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

BAS

HAUT

 

BAS

BANK 05 SECONDAIRE

 

 

 

 

 

 

 

BAS

 

HAUT

HAUT

 

BAS

BANK 06 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

HAUT

HAUT

 

BAS

BANK 07 SECONDAIRE

 

 

 

 

 

 

 

BAS

 

BAS

BAS

 

HAUT

BANK 08 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

BAS

BAS

 

HAUT

BANK 09 SECONDAIRE

 

 

 

 

 

 

 

BAS

 

HAUT

BAS

 

HAUT

BANK 10 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

HAUT

BAS

 

HAUT

BANK 11 SECONDAIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAS

 

BAS

HAUT

 

HAUT

BANK 12 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

BAS

HAUT

 

HAUT

BANK 13 SECONDAIRE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAS

 

HAUT

HAUT

 

HAUT

BANK 14 SECONDAIRE

 

 

 

 

 

 

 

HAUT

 

HAUT

HAUT

 

HAUT

BANK 15 SECONDAIRE

 

 

 

 

 

 

 

Example:

Four OmniView ENTERPRISE Quad-Bus Series KVM Switches (F1DE208C) are daisy-chained together to control 32 computers. The DIP switch on the primary units are set to “BANK Address 00” and the secondary units are each set to a unique BANK address between 01 and 15 (BANK 00 needs to be configured for daisy-chain operation, as noted above).

Installation

Before you begin:

1.Make sure that all computers and switches are powered off and that each Switch has been assigned a unique BANK address.

2.Place primary and secondary Switches in the desired locations.

INSTALLATION

3.Connect the console monitor, keyboard, and mouse to the console ports of the primary Switch(es), as previously described for standalone units, skipping steps 5 and 6.*

Hosts 1 & 2

 

Hosts 3 & 4

 

Hosts 5 & 6

 

Hosts 7 & 8

 

 

 

 

 

 

 

Hosts 1 & 2

 

Hosts 3 & 4

 

Hosts 5 & 6

 

Hosts 7 & 8

 

 

 

 

 

 

 

*Dual-console support available on 2x8 and 2x16 models only.

4.Connect the computers to the Switch as previously described for standalone Switches.

Hosts 1 & 2

Hosts 3 & 4

Hosts 5 & 6

Hosts 7 & 8

Hosts 1 & 2

Hosts 3 & 4

Hosts 5 & 6

Hosts 7 & 8

14

15

Page 10
Image 10
Belkin F1DE216C, F1DE208C, F1DE116C user manual DIP Switch Configuration Chart, Example, Installation Before you begin