Parker Hannifin VERSION 1.0 manual Appendix A. ACR-MOTIONMAX Parameters, SoftwareOptions

Page 30

ACR-MOTIONMAX Installation Guide

30

Appendix A. ACR-MOTIONMAX Parameters

This is the Complete Parameter List for reference.

[CNC_CONFIG]

Description

Default

 

 

 

ParameterPassword=CNC

Used for Parameter & Diagnostics Password

CNC

Mill=1

Set to 1 for Mill or 0 for Lathe

1

NumberOfAxis=3

Sets the Number of Axis ACR-MOTIONMAX is to

3

 

Control

 

InchMetricMode=1

Set to 1 Inch or 0 for Metric

1

HandWheelInstalled=0

Set to 1 in using Remote Pendant

0

UserEditorPath=notepad.e

Pointer to the User configurable Editor Path

 

xe

 

 

ConversationalProgPath=n

Pointer to the User configurable Cam Program Path

notepad.exe

otepad.exe

 

 

AbsoluteArcCenters=1

Set to 1 if using ABS Arc Centers else set to 1 for

1

 

incremental

 

PartFilesPath=C:\Program

Pointer to Partfiles Folder used by ACR-

C:\Program

Files\ACR-

MOTIONMAX

Files\ACR-

MOTIONMAX\Partfiles

 

MOTIONMA

 

 

X\Partfiles

LastFile=

Pointer to the Last File Opened by ACR-

 

 

MOTIONMAX

 

OpenProgWithLastFile=0

Set to 1 to Force ACR-MOTIONMAX to Auto Load

0

 

the last opened Program

 

DefaultFileExt=ALL

Sets the Default file extension to use in Browser

ALL

 

window

 

 

 

 

 

 

 

[SoftwareOptions]

 

 

AxesDisplayOn=1,1,1,0,0

Set to 1 to Make Axis Visible in ACR-MOTIONMAX

1,1,1,0,0

AxisDesignation0=X

Axis Letter

X

AxisDesignation1=Y

Axis Letter

Y

AxisDesignation2=Z

Axis Letter

Z

AxisDesignation3=C

Axis Letter

B

AxisDesignation4=B

Axis Letter (not used)

 

AxisDesignation5=S

Axis Letter (not used)

 

ExactStopRequired=0

Forces Control to Stop Moton at End of Every Rapid

0

 

Move

 

UseADCChanelForOverrid

Specifies to Control System that Overrides are

0

es=0

Derived From the ADC channels

 

RapidOverrideMax=100

Sets the Max that the Override can be set to

100

FeedrateOverrideMax=200

Sets the Max that the Override can be set to

200

SpindleSpeedOverrideMax

Sets the Max that the Override can be set to

150

=150

 

 

RapidOverridePotVoltage=

Specifies to Control Max DC Voltage Derived From

5

5

the ADC channels

 

FeedrateOverridePotVoltag

 

5

e=5

 

 

SpindleSpeedOverridePotV

 

5

oltage=5

 

 

Image 30
Contents ACR-MotionMax Installation Guide North America and Asia ACR-MOTIONMAX Installation GuideParker Hannifin Corporation All Rights Reserved Europe non-German speaking ItalyACR-MOTIONMAX Installation Guide Table of Contents T Code Sequencing ACR-MOTIONMAX Control System Bit Signal BanksStrobe & Done Signals Table Jogging FunctionsSystem Overview Diagram Homing & HandWheelACR-MOTIONMAX to AcroBasic System Start up MotionMaxSys.8k File listing for PCI Type Controller ACR-MOTIONMAX AcroBasic Project Template FilesDefining Bit Variables in AcroBasic AcroBasic Template Files listCode Sequence Examples Example & FormatACR-MOTIONMAX System Setup Diagram Reference FilesACR-MOTIONMAX Directory & File Structure Start Using MotionMax Install the Parker-Acroloop SDK Software Development Kit Install ACR-MOTIONMAX to your PCLoad ACR-MOTIONMAX AcroBasic Project Template Files Test & Phase the Motor/EncodersPrint Reference Files Download Project to Controller FlashTune Axis Gains \Program Files\Parker\ACR-MOTIONMAX\Parfiles\Parameters.Cfg Configure Homing Functions Function Control Signals BitFunction Called Address in Program Configure I/0 Labels for ACR-MOTIONMAX Diagnostics CncInputsConfigCncOutputsConfig Edit the Control Initialization Subroutine ExampleEdit the M Code Functions Rules of operationControl Signals used with S Codes Editing the S Code FunctionACR-MOTIONMAX Installation Guide Edit the T Code Function RequestedToolPositonREM ~ Set Emergency Stop KeyBit = Estop Bit 129 of the Control SignalsEdit the Emergency Stop Function REM ~ Clear Emergency StopSample UserDefinedError.txt for reference Configure Valid Mcodes List for ACR-MOTIONMAX Configure Key ACR-MOTIONMAX Parameters Description DefaultSoftwareOptions Default Speeds Parameter Description Default SpindleOptions Parameter Description DefaultToolChanger Parameter Description Default JogSpeeds Parameter Description DefaultConfigure the Overrides Default ModeRunning ACR-MOTIONMAX for the First Time Test Inputs and Outputs in DiagnosticsStarting ACR-MOTIONMAX for the First Time Step Test JoggingAppendix A. ACR-MOTIONMAX Parameters SoftwareOptions007 SpindleOptionsSoftLimits ToolChangerHomeOffsets SpeedsFastJogSpeeds SystemResolutionJogSpeeds InPositionBandGains2 Gains0Gains1 Gains3Gains7 Spindle Axis Gains5Gains6 AuxFunctionsEditorFontFeatures ScreenColorsDESC8=FLOOD Coolant on M9=1 DESC9=ALL Coolants OFF DESC31= DESC56= DESC81= DESC126=TURN on Tapping Mode ACR-MOTIONMAX Installation Guide End of Parameters

VERSION 1.0 specifications

Parker Hannifin Corporation, founded in 1917, is a global leader in motion and control technologies. With over a century of experience, the company has established itself as a trusted provider of high-quality solutions across various industries, including aerospace, automotive, healthcare, and manufacturing.

One of Parker Hannifin's main features is its diverse product range, which encompasses a wide array of systems and components designed to enhance the efficiency and reliability of machinery and equipment. The company specializes in hydraulic, pneumatic, and electromechanical systems, demonstrating expertise in fluid and motion control. Their products include hydraulic pumps, valves, cylinders, filters, and various seals, all engineered for optimal performance under demanding conditions.

Parker Hannifin is known for its commitment to innovation and technology. The company invests significantly in research and development to stay at the forefront of technological advancements in its field. This dedication has led to the integration of smart technology in their products, enabling real-time monitoring and predictive maintenance capabilities. The incorporation of IoT (Internet of Things) technology allows customers to optimize their operations while reducing downtime and maintenance costs.

Another characteristic of Parker Hannifin is its emphasis on sustainability. The company has made it a priority to develop eco-friendly products that help reduce energy consumption and environmental impact. By leveraging advanced materials and manufacturing techniques, Parker Hannifin produces lightweight components that improve fuel efficiency in transportation applications, contributing to a lower carbon footprint.

Moreover, Parker Hannifin's global footprint allows it to serve customers in various regions while providing localized support. With manufacturing facilities, distribution centers, and sales offices strategically located worldwide, the company ensures quick response times and tailored solutions for specific market needs.

In summary, Parker Hannifin Corporation is a dynamic leader in motion and control technologies, with a commitment to innovation, sustainability, and customer satisfaction. Their extensive range of high-performance products, coupled with advanced technologies and a global presence, positions Parker Hannifin as a reliable partner for industries seeking to enhance operational efficiency and reliability.