Heat & Glo LifeStyle GRAND-I35-SP Burner Ignition and Operation, Standing Pilot Flame Patterns

Page 15

Burner Ignition and Operation

Frequency: Annually

By: Service Technician

Tools needed: Protective gloves, vacuum cleaner, whisk broom, flashlight, voltmeter, indexed drill bit set, and a manometer.

Verify burner is properly secured and aligned with pilot or igniter.

Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.

Replace Glowing embers with new dime-size pieces. DO NOT block ports or obstruct lighting paths. Refer to Section 12 for proper ember placement.

Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. For optimal battery life, locate the battery pack outside of the control cavity on the hearth. This placement will reduce the chances of overheating the batteries during extended burns which could result in reduced battery life or degradation.

Check for smooth lighting and ignition carryover to all ports. Verify that there is no ignition delay.

Inspect for lifting or other flame problems.

Verify air shutter setting is correct. See Section 12 for required air shutter setting. Verify air shutter is clear of dust and debris.

Inspect orifice for soot, dirt and corrosion. Verify orifice size is correct. See Service Parts List for proper orifice sizing.

Verify manifold and inlet pressures. Adjust regulator as required.

Inspect pilot flame pattern and strength. See Figure 3.1 and 3.2 for proper pilot flame pattern. Clean or replace orifice spud as necessary.

Inspect thermocouple/thermopile or IPI flame sensing rod for soot, corrosion and deterioration. Clean with emery cloth or replace as required.

Verify thermocouple/thermopile millivolt output. Replace pilot as necessary. (Standing pilot only)

Verify that there is not a short in flame sense circuit by checking continuity between pilot hood and flame sense rod. Replace pilot as necessary. (IPI only)

Figure 3.1 Standing Pilot Flame Patterns

Figure 3.2 IPI Pilot Flame Patterns

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

15

Image 15
Contents Models What to do if you smell gasDo Discardnot Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery InstallationModule Reset  Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Final inspection by Lighting Instructions IPIDo not Connect 110 VAC to the Control Valve Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsStanding Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsPlacing, Securing and Leveling the Appliance Standing Pilot ModelsIPI Models Installing Adaptor and Termination Cap Masonry Factory BuiltDamper Flashing Kit Optional Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring IntelliFire Plus Ignition System WiringThermocouple Optional Wall Switch Rocker Thermostat or RemoteFAN Blades Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SP Install the Log AssemblyLOG Support Pilot Grate Tines Bracket Grate BAR LOG Groove Flat Spot for Grate BAR END of LOG Rests On Flat Spot Flat Spot forLOG #6 Log #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat Spots G. Install the Log Assembly LOG Support LOG Rests on Grate TineSlot For LOG #6 Corner LOG Flush With Pilot BracketFor LOG #5 Flat Spots Points of LOG Rest onAir Shutter Settings Air Shutter SettingTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Shorts in the wiringReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsAt Depot Service PartsLog Set Assembly StockedMetal Insert, IPI Service Parts SUPREME-I30, SUPREME-I30-SP#19 IPI Valve Assembly GRAND-I35SUPREME-I30 #19 Standing Pilot Valve Assembly Service Parts GRAND-I35-SP, SUPREME-I30-SPService Parts List Standing Pilot Conversion KitsIPI Conversion Kits Contact Information