Heat & Glo LifeStyle GRAND-I35, SUPREME-I30-SP Electrical Information, Wiring Requirements

Page 26

10 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

This appliance comes standard with a 120 VAC cord assembly which has a female plug in to accommodate all control options and accessories. See Figure 10.2. This is required for use of optional accessories (standing pilot ignition) or proper operation of the appliance (IntelliFire Ignition). An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly, or the supplied power cord may be routed out onto the hearth to a nearby outlet.

A 120VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 120 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 120V to the valve or to the appliance wall switch. Incor- rect wiring will damage controls.

Determine if the appliance uses an Intellifire ignition system or standing pilot ignition system.

Open the control access panel or remove the decorative front.

A red or black ignitor button (as shown in Figure 10.1) indicates this appliance is standing pilot ignition.

RED OR BLACK IGNITOR BUTTON

Figure 10.1 Ignitor Button

B. Standing Pilot Ignition System Wiring

The standing pilot ignition system wiring DOES NOT require a 120 VAC supply to operate.

To power appliance with 120VAC to operate a fan or remote control, an outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly or the supplied power cord may be routed out onto the hearth to a nearby outlet.

NOTICE: DO NOT wire 120 VAC to the millivolt valve! This will damage the valve.

If using a thermostat use one compatible with a millivolt gas valve system:

-Install the thermostat in the location as indicated in the thermostat instructions to ensure proper operation of appliance.

-Use low resistance thermostat wire for wiring from ignition system to the wall switch and thermostat.

-Keep wire lengths short as possible by removing any excess wire length.

C. IntelliFire Plus™ Ignition System Wiring

Wire an outlet box (120VAC) in the bottom back corner of the existing solid fuel masonry or factory built fireplace to plug in the cord assembly. The supplied cord assembly may also be routed out onto the hearth to a nearby outlet.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 10.2, IPI Wiring Diagram.

This appliance is equipped with an IntelliFire Plus™ control valve which operates on a 6 volt/1.5 AMP system.

Plug the 6 volt transformer plug into the appliance junction box to supply power to the unit OR install 4 AA cell batteries (not included) into the battery pack before use.

ON/OFF Switch

An ON/OFF switch is included with the appliance surround and should be attached to surround/facing. (See Installation instructions for remote control/fronts).

If desired an additional wall switch or thermostat may be added to system.

26

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

Image 26
Contents Do Discardnot ModelsWhat to do if you smell gas Congratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceBefore Lighting Fireplace Module Reset Nine Hour Safety Shutdown Feature Lighting Instructions IPI Final inspection byLighting Instructions Standing Pilot Ignition Do not Connect 110 VAC to the Control ValveFrequently Asked Questions After Appliance is LitMaintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed TOP View Front View Side View Fireplace Size RequirementsMinimum Fireplace Opening Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsIPI Models Placing, Securing and Leveling the ApplianceStanding Pilot Models Damper Flashing Kit Optional Installing Adaptor and Termination CapMasonry Factory Built Gas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationOptional Wall Switch Rocker Thermostat or Remote ThermocoupleOptional Accessories Requirements FAN BladesFan Wiring with Remote See .H for control module operation instructionsFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup LOG Support Pilot Grate Tines Bracket Grate BAR Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SPInstall the Log Assembly LOG #6 LOG Groove Flat Spot for Grate BAREND of LOG Rests On Flat Spot Flat Spot for LOG #6 Resting on Flat Spots LOG #7 Resting on Flat Spots Log #6Slot  G. Install the Log AssemblyLOG Support LOG Rests on Grate Tine Flat Spots Points of LOG Rest on Corner LOG Flush With Pilot BracketFor LOG #5 For LOG #6Air Shutter Setting Air Shutter SettingsStanding Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsStocked Service PartsLog Set Assembly At DepotService Parts SUPREME-I30, SUPREME-I30-SP Metal Insert, IPISUPREME-I30 #19 IPI Valve AssemblyGRAND-I35 Service Parts GRAND-I35-SP, SUPREME-I30-SP #19 Standing Pilot Valve AssemblyIPI Conversion Kits Service Parts ListStanding Pilot Conversion Kits Contact Information