11 Finishing

A. Mantel and Wall Projections

WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing or finishing material closer than the minimums listed must be construct- ed entirely of noncombustible materials (i.e., steel studs, concrete board, etc).

Clearance to combustible material under the insert is 1/4 inch (6 mm). Clearance from top of fireplace opening for combustibles extending 12 inches max. is 12 inches.

Use leveling legs to raise insert minimum 1/4 inch (6 mm) above combustible material or outer wrap of factory built firebox.

Combustible facings must not extend behind the insert surround. For non-combustible material specifications refer to section 1.E.

EXISTING NON-COMBUSTIBLE FACING

12 IN. MAX.

12 IN. MIN.

Figure 11.1 Clearances to Mantels or other Combustibles above Appliance

30

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

Image 30
Contents Models What to do if you smell gasDo Discardnot Congratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceModule Reset  Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Lighting Instructions IPI Final inspection byLighting Instructions Standing Pilot Ignition Do not Connect 110 VAC to the Control ValveFrequently Asked Questions After Appliance is LitMaintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appliance Standing Pilot ModelsIPI Models Installing Adaptor and Termination Cap Masonry Factory BuiltDamper Flashing Kit Optional Gas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationOptional Wall Switch Rocker Thermostat or Remote ThermocoupleOptional Accessories Requirements FAN BladesFan Wiring with Remote See .H for control module operation instructionsFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SP Install the Log AssemblyLOG Support Pilot Grate Tines Bracket Grate BAR LOG Groove Flat Spot for Grate BAR END of LOG Rests On Flat Spot Flat Spot forLOG #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat Spots Log #6 G. Install the Log Assembly LOG Support LOG Rests on Grate TineSlot Flat Spots Points of LOG Rest on Corner LOG Flush With Pilot BracketFor LOG #5 For LOG #6Air Shutter Setting Air Shutter SettingsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsStocked Service PartsLog Set Assembly At DepotService Parts SUPREME-I30, SUPREME-I30-SP Metal Insert, IPI#19 IPI Valve Assembly GRAND-I35SUPREME-I30 Service Parts GRAND-I35-SP, SUPREME-I30-SP #19 Standing Pilot Valve AssemblyService Parts List Standing Pilot Conversion KitsIPI Conversion Kits Contact Information