Heat & Glo LifeStyle SUPREME-I30-SP, GRAND-I35 Before Lighting Fireplace, Module Reset

Page 9

4.If you intend to use both an optional wired wall switch and the RC300 remote control to operate your fireplace, the wall switch will override any commands given by the remote.

 

SELECTOR

 

SWITCH

STATUS INDICATOR LED

FLAME HI/LO SWITCH

NG/LP SETTING

Figure 2.3 Control Module

5.Module Reset

This module may lock-out under certain conditions. When this occurs, the appliance will not ignite or respond to commands. The module will go into lock-out mode by emitting three audible beeps, then continuously displaying a RED/GREEN error code at its status indicator LED.

Check battery tray. Remove batteries if installed. Batteries should only be installed for use during power outages. See Section G.

Locate the module selector switch. (See Figure 2.3).

Set the module selector switch to the OFF position.

Wait five (5) minutes to allow possible accumulated gas to clear.

Set the module selector switch to ON or REMOTE position.

Start the appliance.

WARNING! Risk of Explosion! DO NOT press the mod- ule reset switch more than one time within a five minute time period. Gas may accumulate in firebox. Call a quali- fied service technician.

Nine Hour Safety Shutdown Feature

This appliance will automatically shut down after nine hours of continuous operation.

NOTICE: If the appliance shuts down after 9 hours of continuous operation, the module must be reset. See Module Reset instructions in this section.

I. Before Lighting Fireplace

Before operating this fireplace for the first time, have a qualified technician:

Verify all shipping materials have been removed from inside and/or underneath the firebox.

Review proper placement of logs, ember material and/ or other decorative materials.

Check the wiring.

Check the air shutter adjustment.

Ensure that there are no gas leaks.

Ensure that the glass is sealed and in the proper position and that the integral barrier is in place.

WARNING! Risk of Fire/Asphyxiation! DO NOT oper- ate fireplace with fixed glass assembly removed.

Determine if this fireplace has a standing pilot or an Intellifire ignition system. Ask your dealer or open control access panel, look at gas valve.

A standing pilot ignition will have a red or black ignitor button (refer to Figure 2.4).

An Intellifire ignition system will not have a button.

RED OR BLACK IGNITOR BUTTON

Figure 2.4 Ignitor Button

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

9

Image 9
Contents Models What to do if you smell gasDo Discardnot Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear SpaceModule Reset  Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Final inspection by Lighting Instructions IPIDo not Connect 110 VAC to the Control Valve Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxStanding Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsPlacing, Securing and Leveling the Appliance Standing Pilot ModelsIPI Models Installing Adaptor and Termination Cap Masonry Factory BuiltDamper Flashing Kit Optional Fuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationThermocouple Optional Wall Switch Rocker Thermostat or RemoteFAN Blades Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SP Install the Log AssemblyLOG Support Pilot Grate Tines Bracket Grate BAR LOG Groove Flat Spot for Grate BAR END of LOG Rests On Flat Spot Flat Spot forLOG #6 Log #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat Spots G. Install the Log Assembly LOG Support LOG Rests on Grate TineSlot For LOG #5 Corner LOG Flush With Pilot BracketFlat Spots Points of LOG Rest on For LOG #6Air Shutter Settings Air Shutter SettingTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Shorts in the wiringReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsStocked At DepotMetal Insert, IPI Service Parts SUPREME-I30, SUPREME-I30-SP#19 IPI Valve Assembly GRAND-I35SUPREME-I30 #19 Standing Pilot Valve Assembly Service Parts GRAND-I35-SP, SUPREME-I30-SPService Parts List Standing Pilot Conversion KitsIPI Conversion Kits Contact Information