Heat & Glo LifeStyle GRAND-I35 owner manual Fireplace Size Requirements, Minimum Fireplace Opening

Page 18

5 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.1. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built firebox in order to gain minimum gas insert opening requirements.

Any smoke shelves, shields and baffles may be removed

from the factory built firebox if attached with mechanical fasteners.

The metal floor of the solid fuel firebox may be removed to facilitate the installation of the insert. The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace must be provided between the insert and the floor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fireplace may never be returned to solid fuel in this condition. The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers.

Cutting of any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited, except the floor as tested for and as noted above.

TOP VIEW

FRONT VIEW

SIDE VIEW

A

E

G

H

C

I

D

F

B

MINIMUM FIREPLACE SIZE

 

Location

GRAND-I35

 

SUPREME-I30

 

 

 

 

 

 

 

Inches

 

Millimeters

Inches

Millimeters

 

 

 

 

 

 

 

 

 

 

A

Rear Width

23-1/2

 

597

20-1/4

514

 

 

 

 

 

 

 

B

Front Width

34-5/8

 

879

30-1/2

775

 

 

 

 

 

 

 

C

Glass Opening Width

31-9/16

 

802

27-7/16

697

 

 

 

 

 

 

 

D

Glass Opening Height

15-11/16

 

398

12-13/16

325

 

 

 

 

 

 

 

E

Height-Front

24

 

610

20-1/2

521

 

 

 

 

 

 

 

F

Height-Rear

21-1/16

 

535

17-5/8

448

 

 

 

 

 

 

 

G**

Unit Depth

16

 

406

14-3/4

375

 

 

 

 

 

 

 

H

Venting Depth

10-1/2

 

267

9-1/2

241

 

 

 

 

 

 

 

I

Height to Top of

22

 

559

18-1/4

464

Glass Frame

 

 

 

 

 

 

 

*Note: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102 mm) to minimum fireplace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).

Figure 5.1 Fireplace Opening

18

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

Image 18
Contents Models What to do if you smell gasDo Discardnot Congratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace IPI Battery Tray/Battery Installation Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceModule Reset  Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Lighting Instructions IPI Final inspection byLighting Instructions Standing Pilot Ignition Do not Connect 110 VAC to the Control ValveFrequently Asked Questions After Appliance is LitMaintenance and Service Logs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection FireboxBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appliance Standing Pilot ModelsIPI Models Installing Adaptor and Termination Cap Masonry Factory BuiltDamper Flashing Kit Optional Gas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Plus Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationOptional Wall Switch Rocker Thermostat or Remote ThermocoupleOptional Accessories Requirements FAN BladesFan Wiring with Remote See .H for control module operation instructionsFinishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SP Install the Log AssemblyLOG Support Pilot Grate Tines Bracket Grate BAR LOG Groove Flat Spot for Grate BAR END of LOG Rests On Flat Spot Flat Spot forLOG #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat Spots Log #6 G. Install the Log Assembly LOG Support LOG Rests on Grate TineSlot Flat Spots Points of LOG Rest on Corner LOG Flush With Pilot BracketFor LOG #5 For LOG #6Air Shutter Setting Air Shutter SettingsTroubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemAppliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsStocked Service PartsLog Set Assembly At DepotService Parts SUPREME-I30, SUPREME-I30-SP Metal Insert, IPI#19 IPI Valve Assembly GRAND-I35SUPREME-I30 Service Parts GRAND-I35-SP, SUPREME-I30-SP #19 Standing Pilot Valve AssemblyService Parts List Standing Pilot Conversion KitsIPI Conversion Kits Contact Information