2 Operating Instructions User Guide

A. Gas Fireplace Safety

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

If you expect that small children or vulnerable adults may come into contact with this fireplace, the following precau- tions are recommended:

Install a physical barrier such as:

-A decorative firescreen.

-Adjustable safety gate.

Keep remote controls out of reach of children.

Never leave children alone near a hot fireplace, whether operating or cooling down.

Teach children to NEVER touch the fireplace.

Consider not using the fireplace when children will be present.

Contact your dealer for more information, or visit: www. hpba.org/safety-information.

To prevent unintended operation when not using your fire- place for an extended period of time (summer months, vacation/trips, etc):

Remove batteries from remote controls.

Turn off wall controls.

Turn off gas controls valve on standing pilot models.

When lighting the pilot light on fireplaces with a standing pilot, remove the fixed glass assembly so you can de- tect presence of residual gas build-up. See Standing Pilot Lighting instructions and Maintenance Tasks.

B. Your Fireplace

WARNING! DO NOT operate fireplace before read- ing and understanding operating instructions. Failure to operate fireplace according to operating instructions could cause fire or injury.

Install a switch lock or a wall/remote control with child protection lockout feature.

APPLIANCE INSTALLED IN EXISTING

SOLID FUEL FIREPLACE

DECORATIVE DOORS

(NOT SHOWN)

SECTION 2.D.

FIXED GLASS ASSEMBLY

(NOT SHOWN)

SECTION 12.H.

HEARTH

MANTEL SECTION 5.B AND 11.A

CLEAR SPACE

SECTION 2.C.

Figure 2.1 General Operating Parts

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

7

Image 7
Contents What to do if you smell gas ModelsDo Discardnot Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches IPI Battery Tray/Battery Installation Nine Hour Safety Shutdown Feature Module ResetBefore Lighting Fireplace Final inspection by Lighting Instructions IPIDo not Connect 110 VAC to the Control Valve Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Firebox Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsStanding Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsTOP View Front View Side View Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceConnecting Vent Pipe Vent LimitsStanding Pilot Models Placing, Securing and Leveling the ApplianceIPI Models Masonry Factory Built Installing Adaptor and Termination CapDamper Flashing Kit Optional Gas Connection Gas InformationFuel Conversion Gas PressureElectrical Information Wiring RequirementsStanding Pilot Ignition System Wiring IntelliFire Plus Ignition System WiringThermocouple Optional Wall Switch Rocker Thermostat or RemoteFAN Blades Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SPLOG Support Pilot Grate Tines Bracket Grate BAR END of LOG Rests On Flat Spot Flat Spot for LOG Groove Flat Spot for Grate BARLOG #6 Log #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat SpotsLOG Support LOG Rests on Grate Tine  G. Install the Log AssemblySlot For LOG #6 Corner LOG Flush With Pilot BracketFor LOG #5 Flat Spots Points of LOG Rest onAir Shutter Settings Air Shutter SettingSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Shorts in the wiringReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsAt Depot Service PartsLog Set Assembly StockedMetal Insert, IPI Service Parts SUPREME-I30, SUPREME-I30-SPGRAND-I35 #19 IPI Valve AssemblySUPREME-I30 #19 Standing Pilot Valve Assembly Service Parts GRAND-I35-SP, SUPREME-I30-SPStanding Pilot Conversion Kits Service Parts ListIPI Conversion Kits Contact Information