H. Fixed Glass Assembly

Removing Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

The glass assembly fastens to the fireplace in four places. Four of the fastening mechanisms are spring- loaded glass latches. An example of the glass latch is shown in Figure 12.3.

To release glass assembly, pull the two bottom spring-loaded latches forward and allow them to re- tract away from the glass assembly. Slide the glass assembly outward and downward until the top latches disengage.

Replacing Fixed Glass Assembly

Tilt glass assembly toward fireplace and slide glass assembly upward to engage top latches. Verify top latches are fully engaged and then fasten the two bottom latches.

I. Air Shutter Setting

Air shutter settings should be adjusted by a qualified ser- vice technician at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 12.4.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

Figure 12.4 Air Shutter

Air Shutter Settings

 

NG

LP

SUPREME-I30

3/8 in.

1/2 in.

GRAND-I35

3/8 in.

1/2 in.

Figure 12.3 Fixed Glass Assembly

Heat & Glo • Grand-I35, Grand-I35-SP, Supreme-I30, Supreme-I30-SP2206-900 Rev. K • 6/11

37

Image 37
Contents What to do if you smell gas ModelsDo Discardnot Homeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyIPI Battery Tray/Battery Installation Clear Space Nine Hour Safety Shutdown Feature Module ResetBefore Lighting Fireplace Final inspection by Lighting Instructions IPIDo not Connect 110 VAC to the Control Valve Lighting Instructions Standing Pilot IgnitionAfter Appliance is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianLogs FireboxStanding Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsTOP View Front View Side View Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting ComponentsStanding Pilot Models Placing, Securing and Leveling the ApplianceIPI Models Masonry Factory Built Installing Adaptor and Termination CapDamper Flashing Kit Optional Fuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationThermocouple Optional Wall Switch Rocker Thermostat or RemoteFAN Blades Optional Accessories RequirementsSee .H for control module operation instructions Fan Wiring with RemoteClearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-I35 Models GRAND-I35, GRAND-I35-SPLOG Support Pilot Grate Tines Bracket Grate BAR END of LOG Rests On Flat Spot Flat Spot for LOG Groove Flat Spot for Grate BARLOG #6 Log #6 LOG #6 Resting on Flat Spots LOG #7 Resting on Flat SpotsLOG Support LOG Rests on Grate Tine  G. Install the Log AssemblySlot For LOG #5 Corner LOG Flush With Pilot BracketFlat Spots Points of LOG Rest on For LOG #6Air Shutter Settings Air Shutter SettingSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Shorts in the wiringReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsStocked At DepotMetal Insert, IPI Service Parts SUPREME-I30, SUPREME-I30-SPGRAND-I35 #19 IPI Valve AssemblySUPREME-I30 #19 Standing Pilot Valve Assembly Service Parts GRAND-I35-SP, SUPREME-I30-SPStanding Pilot Conversion Kits Service Parts ListIPI Conversion Kits Contact Information