Heat & Glo LifeStyle XLR-PLUS-PB-AU, XLR-PLUS-N-AU Lighting Instructions IPI, Final inspection by

Page 12

I. Lighting Instructions (IPI)

The IPI system may be operated with four C-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer.

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS (IPI)

1. This appliance is equipped with an ignition

device which automatically lights the burner.

DO NOT try to light the burner by hand.

A. This appliance is equipped with an intermittent pilot ignition (IPI) device which automatically lights the burn- er. DO NOT try to light the burner by hand.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

GAS

VALVE

2.

Wait five (5) minutes to clear out any gas.

 

Then smell for gas, including near the floor. If

 

you smell gas, STOP! Follow “B” in the Safety

 

Information located on the left side of this la-

 

bel. If you do not smell gas, go to next step.

3.

To light the burner:

 

Equipped with wall switch: Turn ON/OFF switch

 

to ON.

 

 

 

WARNING:

 

CAUTION:

DO NOT CONNECT LINE VOLT-

Hot while in operation. DO NOT touch.

AGE (110/120 VAC OR 220/240

Keep children, clothing, furniture, gaso-

VAC) TO THE CONTROL VALVE.

line and other liquids having flammable

Improper installation, adjustment, al-

vapors away.

DO NOT operate the appliance with

teration, service or maintenance can

cause injury or property damage. Re-

fixed glass assembly removed, cracked

or broken. Replacement of the fixed

fer to the owner’s information manual

glass assembly should be done by a

provided with this appliance.

licensed or qualified service person.

This appliance needs fresh air for

 

safe operation and must be installed

NOT FOR USE

so there are provisions for adequate

WITH SOLID FUEL

combustion and ventilation air.

If not installed, operated, and main-

For use with natural gas and propane.

tained in accordance with the manufac-

A conversion kit, as supplied by the

turer’s instructions, this product could

manufacturer, shall be used to convert

expose you to substances in fuel or

this appliance to the alternate fuel.

fuel combustion which are known to the

Also Certified for Installation in a

State of California to cause cancer, birth

Bedroom or a Bedsitting Room.

defects, or other reproductive harm.

For assistance or additional informa-

Keep burner and control compartment

tion, consult a qualified installer, ser-

clean. See installation and operating

vice agency or the gas supplier.

instructions accompanying appliance.

 

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Equipped with remote or wall control: Press

ON or FLAME button.

Equipped with thermostat: Set temperature to

desired setting.

4. If the appliance does not light after three tries,

call your service technician or gas supplier.

TO TURN OFF

GAS TO APPLIANCE

1.Equipped with wall switch: Turn ON/OFF switch to OFF.

Equipped with remote or wall control: Press OFF button.

Equipped with thermostat: Set temperature to lowest setting.

2.Service technician should turn off electric power to the control when performing service.

593-913G

Final inspection by

12

Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU2264-900 Rev. M • 7/12

Image 12
Contents Ref No GSCS20194 AS45532008 SAI GlobalWhat to do if you smell gas Models XLR-PLUS-N-AU XLR-PLUS-PB-AU Congratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingComponent Access FinishingAustralian Warranty Information Limited Lifetime WarrantyOther Rights This warranty is void if Perth Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesIPI Battery Tray/Battery Installation Clear SpaceLighting Instructions IPI Final inspection byAGE 110/120 VAC or 220/240 Nine Hour Safety Shutdown Feature Control Module OperationFrequently Asked Questions Initial Break-in ProcedureAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionFirebox Control Compartment and Firebox TopGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesMantel and Wall Projections Mantels Combustible/Non-CombustibleMantel Leg Combustible/Non-Combustible Front Side Finishing DetailTermination Locations Vent Termination Minimum ClearancesMIN. Clearance in. mm Vent Information and Diagrams Top Vent Horizontal Termination Venting with 1 elbow Minimum H1 MaximumTop Vent Horizontal Termination Venting with 2 elbows Minimum H1 + H2 MaximumTop Vent Vertical Termination No Elbows V1 Max= 13.4 m 44 ft Exhaust Restrictor InstructionsTop Vent Vertical Termination Venting with 2 elbows V1 Minimum Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 3 elbows V1 Minimum H1 + H2 Maximum V1 + V2 MinimumTop Vent Vertical Termination Venting with 4 elbows Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Pipe SLPInstall Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation Appliance Preparation Top VentInstalling the Optional Heat-Zone-240V Kit Securing and Leveling the ApplianceInstalling Vent Pipe SLP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Install Decorative Wall ComponentsHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap 17 Venting through the WallGas Information Gas ConnectionNatural Gas Propane ButaneAccess Through the Valve Assembly Valve Pressure TapsWiring Requirements IntelliFire Plus Ignition System WiringOptional Accessories Requirements Optional Remote Control Receiver LocationElectrical Service and Repair Blower Junction Cord InformationKit Contents Fireplace Specific InformationIntroduction Installation Precautions Changing Temperature ScaleInstallation of Remote Control Housing Determine LocationAUX300CE Module Installation Fan InstallationProgramming the RC300AU to the Control Module Idle When Remote is in on Mode Standby modeDisplay Screen Function ButtonsAbout on Mode About OFF ModeAdjusting Flame Height Adjusting Fan SpeedAdjusting Thermostat Adjusting TimerSetting the Child Lock Power OutageFrequently Asked Questions/Troubleshooting Symptom Possible Cause Corrective ActionNon-Combustible Materials Specification FinishingFraming and Finishing Instructions Finishing InstructionsFinishing Details Finish and Sealing Joints Finishing Around Opening with Gypsum WallboardGas Pipe Requirements PaintingTOP View Unlimited Facing Material Overlap Fit Method Tonic or Martini Decorative FrontDecorative Fronts Inside and Overlap Method See .CDimensions of Tonic Decorative Front See Figures 13.15Appliance Setup Air Shutter Setting Media OptionsVerify Performance of Appliance Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System Ues to spark, and main Frequently Asked Questions/Troubleshooting Component Access Access Through the Valve Assembly Gas Valve Replacement Pilot Assembly ReplacementAppliance Dimension Diagram Reference MaterialsMaintenance Tasks Inspect Maintenance TasksVent Components Diagrams DVP-HPC Cap Brick ExtensionSLP-45 45 Elbow SLP90- 90 ElbowCeiling Firestop SupportSnorkel Support Box-BlackSLP-HRC-SS SLP-HRC-ZC-SS Horizontal Termination CAP Service Parts XLR-PLUS-N-AU, XLR-PLUS-PB-AU#15 Valve Assembly Service Parts List XLR-PLUS-N-AU, XLR-PLUS-PB-AUContact Information