F. Install Metal Roof Flashing
•See minimum vent heights for various pitched roofs (Figure 10.11) to determine the length of pipe to extend through the roof.
•Slide the roof flashing over the pipe sections extending through the roof as shown in Figure 10.12.
HORIZONTAL
OVERHANG
510 mm MIN.
610 mm MIN.
VERTICAL
WALL
LOWEST
DISCHARGE
OPENING
TERMINATION
CAP
X
305 mm
ROOF PITCH
IS X/ 305 mm
H (MIN.) - MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING
Angle | H (Min.) mm |
............................................................500* | |
............................................................500* | |
............................................................500* | |
............................................................610* | |
............................................................760 | |
............................................................990 | |
.........................................................1220. | |
.........................................................1520. | |
.........................................................1830. | |
.........................................................2130. | |
.........................................................2290. | |
.........................................................2440. |
*910 mm minimum in snow regions
Figure 10.11 Minimum Height From Roof To Lowest Discharge Opening
NOTICE: Failure to properly caulk the roof flashing and pipe seams could cause water entry.
•Caulk the gap between the roof flashing and the outside diameter of the pipe.
•Caulk the perimeter of the flashing where it contacts the roof surface. See Figure 10.12.
•Caulk the overlap seam of any exposed pipe sections that are located above the roof line.
CAULK
Figure 10.12
G. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.
•Connect both halves of the storm collar with two screws (see Figure 10.13).
•Wrap the storm collar around the exposed pipe section closest to the roof and align brackets. Insert a bolt (provided) through the brackets and tighten the nut to complete the storm collar assembly. Make sure the collar is tight against the pipe section.
•Slide the assembled storm collar down the pipe section until it rests on the roof flashing (see Figure 10.14).
•Caulk around the top of the storm collar (see Figure 10.15).