Heat & Glo LifeStyle RED60 2159-900 manual MAX. Elbows MAX. Total Vent RUN FT MAX. VERT. Drop FT

Page 47

H1

V1

Note: 1 ft. of vertical drop decreases horizontal length by 2 ft.

V2

MAXIMUM

VERTICAL

DROP

H2

NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run

DIRECT VENT WITH 2 FT. MINIMUM VERTICAL (V1) OFF TOP OF APPLIANCE

MAX. ELBOWS

MAX. TOTAL VENT RUN (FT.)

 

MAX. VERT. DROP (FT.)

(45° & 90°)

Total V + Total H

 

V2

3

24 ft.

 

7 ft.

4

17 ft.

 

7 ft.

 

 

 

 

 

DIRECT VENT WITH 3 FT. MINIMUM VERTICAL (V1)OFF TOP OF APPLIANCE

 

MAX. ELBOWS

MAX. TOTAL VENT RUN (FT.)

MAX. VERT. DROP (FT.)

 

(45° & 90°)

Total V + Total H

 

V2

 

3

29 ft.

 

7 ft.

 

4

22 ft.

 

7 ft.

 

 

 

DIRECT VENT WITH 4 FT. MINIMUM VERTICAL (V1) OFF TOP OF APPLIANCE

MAX. ELBOWS

MAX. TOTAL VENT RUN (FT.)

 

MAX. VERT. DROP (FT.)

(45° & 90°)

Total V + Total H

 

V2

3

34 ft.

 

7 ft.

4

26 ft.

 

7 ft.

Figure 7.49

Heat & Glo • RED60 • 2159-900 Rev. R • 9/12

47

Image 47
Contents What to do if you smell gas ModelsHomeowner Reference Information CongratulationsUser Guide Table of ContentsReference Materials Appliance SetupTroubleshooting FinishingLimited Lifetime Warranty Limited Lifetime Warranty Hearth & Home Technologies IncWarranty Conditions Limited Lifetime WarrantyListing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions Your Fireplace Clear Space Gas Fireplace SafetyOperating Instructions User Guide Before Lighting Fireplace Fixed Glass AssemblyDecorative Doors and Fronts Control Module OperationFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Doors, Surrounds, Fronts Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningFirebox Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection VentingTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Selecting Appliance Location Framing and ClearancesClearances Minimum Framing DimensionsConstructing the Appliance Chase = Acceptable NON-COMBUSTIBLE Mantel LEG Zone Mantel and Wall ProjectionsTOP View Fireplace MIN MAX Opening Unlimited Vent Termination Minimum Clearances Termination LocationsMinimum Clearances for Termination Covered Alcove ApplicationsVent Information and Diagrams Installation Guidelines Installation Instructions and Venting In- formation PVI-DVPComponents and Service Parts List Installation PrecautionsVent Pipe Regulations Installation of Vent PipeFraming and Clearances Chassis Dimensions Framing DimensionsAccess Panel Framing Dimensions Chase Appliance PVI-DVP Connections Wiring the PVI-DVPWire Harness ScrewsVacuum Switch Orientation Installation InspectionOperating Instructions MaintenanceMinimum + H 1 Maximum Vent DiagramsTop Vent Horizontal Termination Venting with 1 elbow V1 Minimum V1 + H1 + H2 Maximum Top Vent Horizontal Termination Venting with 2 elbowsMinimum Total V + Total H Maximum Top Vent Horizontal Termination Venting with 3 elbowsV1 Minimum V1 + V2 + H1 + H2 Maximum Elbows Minimum Total V + Total H Maximum25 Vertical Vent Maximum Minimum V1 + V2 + H Maximum Top Vent Vertical Termination Venting with 2 elbowsMinimum V1 + V2 + H1 + H2 Maximum Top Vent Vertical Termination Venting with 3 elbowsDirect Vent with 4 FT. Minimum Vertical OFF TOP of Appliance 29 Power Vent Positioned After Vertical Drop Common Vent System is Prohibited These Instructions Must Remain with the EquipmentComponents Venting of More than ONE Appliance in aWiring the PVK-80 Power Vent Installation Inspection 8K1-PVI AUX300 Operating Instructions To Reassemble the Power Vent V1 Minimum V1 + H1 Maximum PVK-80 Top Vent Horizontal Termination Venting with 1 elbowPVK-80 Top Vent Horizontal Termination Venting with 2 elbows Elbows V1 + V2 Minimum Total V + Total H Maximum MAX. Elbows MAX. Total Vent RUN FT MAX. VERT. Drop FT Combustible Wall Penetration Vent Clearances and FramingPipe Clearances to Combustibles Wall Penetration FramingPipe DVP Install the Ceiling FirestopVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Rope Ring Appliance PreparationTop Vent FiberglassSecuring and Leveling the Appliance Setting the Fireplace into the FramingDetail a Active Convection TechnologyAssemble Vent Sections Installing Vent Pipe DVP PipeSecure The Vent Sections Assemble Slip SectionsDisassemble Vent Sections Install Decorative Ceiling ComponentsAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Horizontal Termination Cap Gas Pressure Gas InformationFuel Conversion Gas Connection Gas and Electrical AccessElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Optional Configuration RequirementsWires from touching the blower Optional LED Lighting Circuit Switch Tripped Color ProducedActive Convection Blower Replacement Electrical Service and Repair Junction Box InstallationBlower TAB on Mounting Plate Slot on Blower HousingFraming and Finishing Instructions Non-Combustible Materials SpecificationFinishing Splatter GuardPainting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard IN. Thick Facing MaterialOverlap Fit Method Mesh Fronts 10 Mesh Front InstallationAppliance Setup Rock Media Placement JIG Pilot Shield Tools Required Kit ContentsPorcelain Instructions RED60 Model Without MediaNNN NNP InstallationDescription Part Number Service PartsRED60 Model With Media InstallationBend TAB UP Back Panel Pieces Granite Instructions19-3/8 Notched Area Over Pilot Installing First Back Panel Granite PieceGlass Assembly Tabs Face Glass Assembly Placing Back Panel Piece Glass Frame TAB Retaining TAB ALL Gaps Equal Tabs Sheet Metal Refractory InstructionsSMR-60NL Item Description Comments Part NumberAir Shutter Settings Install the MeshAir Shutter Setting IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Pilot PVI-DVP TroubleshootingReference Materials Appliance Dimension DiagramDVP-AS2 Vent Components DiagramsDVP vent components DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2RF6M RF12M DVP-FBHT RED60 RED60 Service Parts ServiceContact Information

RED60 2159-900 specifications

The Heat & Glo LifeStyle RED60 2159-900 is a modern and innovative gas fireplace that exemplifies cutting-edge design and advanced heating technology. With its sleek aesthetics and smart features, this fireplace is designed to elevate both comfort and style in any living space.

One of the main features of the RED60 is its impressive heat output. This model boasts a high efficiency rating, ensuring that homeowners can enjoy warmth without excessive energy consumption. The fireplace can deliver an output of up to 60,000 BTUs, making it suitable for both large and small areas. This efficient performance means less environmental impact, aligning with the growing emphasis on sustainability in home heating solutions.

The design of the Heat & Glo LifeStyle RED60 is another standout aspect. Its expansive glass viewing area provides a panoramic view of the flames, creating a beautiful focal point in any room. The minimalist frame enhances the contemporary aesthetic, allowing it to seamlessly complement various interior styles, from modern chic to traditional elegance.

In terms of technology, the RED60 incorporates advanced combustion systems, ensuring cleaner emissions without sacrificing performance. This technology not only contributes to a healthier indoor environment but also helps reduce the carbon footprint associated with home heating. Additionally, the fireplace features a patented heat distribution system, which optimally circulates warmth throughout the space, eliminating cold spots and enhancing overall comfort.

The RED60 also offers convenience through its intuitive remote control system. Users can easily adjust the flame height, heat output, and even set timers, providing ultimate flexibility in managing their indoor climate. For those who prefer a more hands-on approach, manual controls are also available, making it user-friendly for everyone.

Moreover, the installation process is simplified with the unit's flexible venting options, which can accommodate various configurations to suit different homes. Whether designing for a new build or retrofitting an existing space, this versatility appeals to homeowners and builders alike.

In summary, the Heat & Glo LifeStyle RED60 2159-900 is a blend of style, efficiency, and advanced technology. Its high heat output, sleek design, and intuitive controls make it an excellent choice for anyone seeking to enhance their living environment with a modern gas fireplace.