H.Requirements for the Commonwealth of Massachusetts

For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, in- cluding but not limited to decks and porches, the following requirements shall be satisfied:

Installation of Carbon Monoxide Detectors

At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addi- tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- tor with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fu- eled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

Approved Carbon Monoxide Detectors

Each carbon monoxide detector as required in accor- dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

Signage

A metal or plastic identification plate shall be permanent- ly mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fu- eled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) in. in size, “GAS

VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- STRUCTIONS”.

Inspection

The state or local gas inspector of the side wall horizon- tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

Exemptions

The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

Product Approved side wall horizontally vented gas fu- eled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS

Gas Equipment Venting System Provided

When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

Detailed instructions for the installation of the venting system design or the venting system components; and

A complete parts list for the venting system design or venting system.

Gas Equipment Venting System NOT Provided

When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not pro- vide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer:

The referenced “special venting system” instructions shall be included with the appliance or equipment in- stallation instructions; and

The “special venting systems” shall be Product Ap- proved by the Board, and the instructions for that sys- tem shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Ap- proved side wall horizontally vented gas fueled equip- ment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

See Gas Connection section for additional Common- wealth of Massachusetts requirements.

8

Heat & Glo • RED60 • 2159-900 Rev. R • 9/12

Image 8
Contents Models What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsLimited Lifetime Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyLimited Lifetime Warranty Warranty ConditionsListing and Code Approvals Manufacturer Requirements Requirements for the Commonwealth of MassachusettsVent Directly BELOW. Keep Clear of ALL OB- Structions Your Fireplace Clear Space Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Decorative Doors and FrontsControl Module Operation Before Lighting FireplaceLighting Instructions IPI Final inspection byAfter Fireplace is Lit Frequently Asked QuestionsInitial Break-in Procedure Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Doors, Surrounds, FrontsMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting FireboxGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Selecting Appliance LocationClearances Minimum Framing DimensionsConstructing the Appliance Chase = Acceptable NON-COMBUSTIBLE Mantel LEG Zone Mantel and Wall ProjectionsTOP View Fireplace MIN MAX Opening Unlimited Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Minimum Clearances for TerminationVent Information and Diagrams Installation Instructions and Venting In- formation PVI-DVP Components and Service Parts ListInstallation Precautions Installation GuidelinesInstallation of Vent Pipe Framing and Clearances Chassis DimensionsFraming Dimensions Vent Pipe RegulationsAccess Panel Framing Dimensions Chase Appliance Wiring the PVI-DVP Wire HarnessScrews PVI-DVP ConnectionsInstallation Inspection Vacuum Switch OrientationMaintenance Operating InstructionsMinimum + H 1 Maximum Vent DiagramsTop Vent Horizontal Termination Venting with 1 elbow Top Vent Horizontal Termination Venting with 2 elbows V1 Minimum V1 + H1 + H2 MaximumTop Vent Horizontal Termination Venting with 3 elbows V1 Minimum V1 + V2 + H1 + H2 MaximumElbows Minimum Total V + Total H Maximum Minimum Total V + Total H Maximum25 Vertical Vent Maximum Top Vent Vertical Termination Venting with 2 elbows Minimum V1 + V2 + H MaximumTop Vent Vertical Termination Venting with 3 elbows Minimum V1 + V2 + H1 + H2 MaximumDirect Vent with 4 FT. Minimum Vertical OFF TOP of Appliance 29 Power Vent Positioned After Vertical Drop These Instructions Must Remain with the Equipment ComponentsVenting of More than ONE Appliance in a Common Vent System is ProhibitedWiring the PVK-80 Power Vent Installation Inspection 8K1-PVI AUX300 Operating Instructions To Reassemble the Power Vent PVK-80 Top Vent Horizontal Termination Venting with 1 elbow V1 Minimum V1 + H1 MaximumPVK-80 Top Vent Horizontal Termination Venting with 2 elbows Elbows V1 + V2 Minimum Total V + Total H Maximum MAX. Elbows MAX. Total Vent RUN FT MAX. VERT. Drop FT Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPVaulted Ceiling Installation Install Attic Insulation ShieldFlat Ceiling Installation Appliance Preparation Top VentFiberglass Rope RingSetting the Fireplace into the Framing Securing and Leveling the ApplianceActive Convection Technology Detail aInstalling Vent Pipe DVP Pipe Assemble Vent SectionsAssemble Slip Sections Secure The Vent SectionsInstall Decorative Ceiling Components Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Horizontal Termination Cap Gas Pressure Gas InformationFuel Conversion Gas and Electrical Access Gas ConnectionWiring Requirements IntelliFire PlusTM Ignition System WiringOptional Configuration Requirements Electrical InformationWires from touching the blower Switch Tripped Color Produced Optional LED Lighting CircuitElectrical Service and Repair Junction Box Installation Active Convection Blower ReplacementSlot on Blower Housing Blower TAB on Mounting PlateNon-Combustible Materials Specification FinishingSplatter Guard Framing and Finishing InstructionsPainting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Facing Material IN. ThickOverlap Fit Method 10 Mesh Front Installation Mesh FrontsAppliance Setup Rock Media Placement JIG Pilot Shield Kit Contents Porcelain InstructionsRED60 Model Without Media Tools RequiredInstallation NNN NNPService Parts Description Part NumberInstallation RED60 Model With MediaBend TAB UP Granite Instructions Back Panel Pieces19-3/8 Installing First Back Panel Granite Piece Notched Area Over PilotGlass Assembly Tabs Face Glass Assembly Placing Back Panel Piece Glass Frame TAB Retaining TAB Sheet Metal Refractory Instructions ALL Gaps Equal TabsItem Description Comments Part Number SMR-60NLAir Shutter Settings Install the MeshAir Shutter Setting IntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action PVI-DVP Troubleshooting PilotAppliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 DVP vent componentsRF6M RF12M DVP-FBHT RED60 RED60 Service Service PartsContact Information

RED60 2159-900 specifications

The Heat & Glo LifeStyle RED60 2159-900 is a modern and innovative gas fireplace that exemplifies cutting-edge design and advanced heating technology. With its sleek aesthetics and smart features, this fireplace is designed to elevate both comfort and style in any living space.

One of the main features of the RED60 is its impressive heat output. This model boasts a high efficiency rating, ensuring that homeowners can enjoy warmth without excessive energy consumption. The fireplace can deliver an output of up to 60,000 BTUs, making it suitable for both large and small areas. This efficient performance means less environmental impact, aligning with the growing emphasis on sustainability in home heating solutions.

The design of the Heat & Glo LifeStyle RED60 is another standout aspect. Its expansive glass viewing area provides a panoramic view of the flames, creating a beautiful focal point in any room. The minimalist frame enhances the contemporary aesthetic, allowing it to seamlessly complement various interior styles, from modern chic to traditional elegance.

In terms of technology, the RED60 incorporates advanced combustion systems, ensuring cleaner emissions without sacrificing performance. This technology not only contributes to a healthier indoor environment but also helps reduce the carbon footprint associated with home heating. Additionally, the fireplace features a patented heat distribution system, which optimally circulates warmth throughout the space, eliminating cold spots and enhancing overall comfort.

The RED60 also offers convenience through its intuitive remote control system. Users can easily adjust the flame height, heat output, and even set timers, providing ultimate flexibility in managing their indoor climate. For those who prefer a more hands-on approach, manual controls are also available, making it user-friendly for everyone.

Moreover, the installation process is simplified with the unit's flexible venting options, which can accommodate various configurations to suit different homes. Whether designing for a new build or retrofitting an existing space, this versatility appeals to homeowners and builders alike.

In summary, the Heat & Glo LifeStyle RED60 2159-900 is a blend of style, efficiency, and advanced technology. Its high heat output, sleek design, and intuitive controls make it an excellent choice for anyone seeking to enhance their living environment with a modern gas fireplace.