Heat & Glo LifeStyle RED40ST owner manual H. Lighting Instructions IPI, Final inspection by

Page 11
H. Lighting Instructions (IPI)

H. Lighting Instructions (IPI)

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

FOR YOUR SAFETY LIGHTING LIGHTING VAC) TO THE CONTROL VALVE.NOT FOR USE

INSTRUCTIONS (IPI)

1. This appliance is equipped with an ignition

device which automatically lights the burner.

DO NOT try to light the burner by hand.

A. This appliance is equipped with an intermittent pilot ignition (IPI) device which automatically lights the burn- er. DO NOT try to light the burner by hand.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

GAS

VALVE

2.

Wait five (5) minutes to clear out any gas.

 

Then smell for gas, including near the floor. If

 

you smell gas, STOP! Follow “B” in the Safety

 

Information located on the left side of this la-

 

bel. If you do not smell gas, go to next step.

3.

To light the burner:

 

Equipped with wall switch: Turn ON/OFF switch

 

to ON.

WARNING:

DO NOT CONNECT LINE VOLT- AGE (110/120 VAC OR 220/240

VAC) TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the manufac- turer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause cancer, birth defects, or other reproductive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

CAUTION:

Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

DO NOT operate the appliance with fixed glass assembly removed, cracked or broken. Replacement of the fixed glass assembly should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

Equipped with remote or wall control: Press

ON or FLAME button.

Equipped with thermostat: Set temperature to

desired setting.

4. If the appliance does not light after three tries,

call your service technician or gas supplier.

 TO TURN OFF TO TURN OFF Final inspection by

GAS TO APPLIANCE

1.Equipped with wall switch: Turn ON/OFF switch to OFF.

Equipped with remote or wall control: Press OFF button.

Equipped with thermostat: Set temperature to lowest setting.

2.Service technician should turn off electric power to the control when performing service.

593-913G

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Final inspection by

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

11

 

Image 11
Contents Owner’s Manual Models RED40 RED40STNOTICE •What to do if you smell gasHomeowner Reference Information A. Congratulations3 Maintenance and Service Table of ContentsSafety Alert Key Installer Guide13 Finishing 14 Appliance Setup15 Troubleshooting  = Contains updated informationWARRANTY PERIOD B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY COVERAGEThis warranty is void if B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS WARRANTY EXCLUSIONSB. Glass Specifications D. High Altitude Installations1 Listing and Code Approvals A. Appliance CertificationInstallation of Carbon Monoxide Detectors C. Clear Space A. Gas Fireplace Safety2 Operating Instructions User Guide B. Your Fireplaceerate fireplace with fixed glass assembly removed E. Fixed Glass AssemblyD. Decorative Doors and Fronts G. Before Lighting FireplaceLIGHTING INSTRUCTIONS IPI H. Lighting Instructions IPIFinal inspection by FOR YOUR SAFETY READ BEFORE LIGHTING•Some people may be sensitive to smoke and odors J.Frequently Asked QuestionsI. After Fireplace is Lit Initial Break-inProcedureRemote Control 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Glass CleaningFirebox B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection VentingFigure 4.1 Typical System Getting StartedA. Typical Appliance System Installer GuideD. Inspect Appliance and Components B. Design and Installation ConsiderationsC.Tools and Supplies Needed A. Selecting Appliance Location 5 Framing and ClearancesFigure 5.2 Appliance Locations RED40ST 1/2 IN1/2 IN. C C. Clearances B. Constructing the Appliance ChaseMINIMUM FRAMING DIMENSIONS Non-CombustibleMantels D. Mantel and Wall ProjectionsDimensions of Non-Combustibles Combustible MantelsH Min. Ft 6 Termination LocationsA. Vent Termination Minimum Clearances Roof PitchV= VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDCovered Alcove Applications B. Vent Table Key 7 Vent Information and DiagramsE. Vent Diagrams A. Approved PipeH1 Maximum Top Vent - Horizontal TerminationVenting with 1 elbow V1 MinimumH1 + H2 Maximum 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows INSTALLED HORIZONTALLYH2 V2 H1 V1 1. Top Vent - Horizontal TerminationVenting with 3 elbows continuedExhaust restrictor Instructions Top Vent - Vertical Termination No ElbowsV = 3 ft Min. 1m, 50 ft. Max. 15.2 m V2 H1 V1 Top Vent - Vertical TerminationH1 + H2 Maximum DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE Between ceiling firestops 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles B. Wall Penetration FramingC. Install the Ceiling Firestop Vaulted Ceiling Installation D. Install Attic Insulation ShieldFlat Ceiling Installation A. Appliance Preparation 9 Appliance Preparation•Sagging or loose insulation B. Securing and Leveling the ApplianceSetting the Fireplace into the Framing WARNING! Risk of Fire! Prevent contact withC. Active Convection Technology A. Assemble Vent Sections 10 Installing Vent Pipe DVP PipePilot hole B. Assemble Slip SectionsC. Secure The Vent Sections D. Disassemble Vent Sections E. Install Decorative Ceiling ComponentsCAUTION! Risk of Cuts, Abrasions or Flying Debris F. Install Metal Roof FlashingG. Assemble and Install Storm Collar CAULKH. Install Vertical Termination Cap Figure 10.20 Venting Through the Wall J. Install Horizontal Termination CapB. Gas Pressure 11 Gas InformationA. Fuel Conversion •Ensure adequate ventilation C. Gas Connection12 Electrical Information A. Wiring RequirementsB. IntelliFire Ignition System Wiring C. Optional Accessories RequirementsREMOTE RECEIVER Optional Remote Control Receiver LocationCOLOR PRODUCED D. Optional LED Lighting CircuitSWITCH TRIPPED KNOCKOUT E. Electrical Service and RepairF. Junction Box Installation G. Active Convection Blower ReplacementFAN MOUNT FASTENER SIDE BURNER SCREWFigure 12.18. Removed Mounting Plate SLOT ON BLOWER HOUSINGBLOWER TAB ON MOUNTING PLATE Figure 12.17. Remove Mounting PlateFinishing Instructions 13 FinishingA. Splatter Guard B. Framing and Finishing InstructionsFigure 13.1 Finishing Details Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard PaintingDimensions of Combustibles C. Mantel and Wall ProjectionsFigure 13.6 Framing and Framing Materials-RED40ST D. Facing MaterialFigure 13.5 Framing and Framing Materials-RED40 Figure 13.7 Overlap Fit Method Non-CombustibleFinish Materials0 - 1 inch thickness-OverlapFit Method 13-1/8IN 0 Inches to 4 Inches Thick Inside Fit MethodFigure 13.9 Inside Fit Method 42-3/4INFigure 13.11. Mesh Front Installation E. Mesh FrontsASSEMBLY MESH FRAME ASSEMBLYD. Accessories 14 Appliance SetupA. Remove Fixed Glass Assembly C. Clean the ApplianceRemoving Fixed Glass Assembly H. Fixed Glass AssemblyI. Install the Mesh J. Air Shutter SettingPossible Cause 15 TroubleshootingA. IntelliFire Ignition System SymptomIntelliFire Ignition System - continued 16 Reference Materials A. Appliance Dimension DiagramA F G Figure 16.2 Appliance Dimensions RED40STM N O P T R Q SDVP-AS2 B. Vent Components DiagramsFigure 16.2 DVP vent components DVP-TRAPK1 B. Vent Components Diagrams continuedDVP-TRAP1 DVP-TRAP231 in 330 mm 8-1/8in13 in 206 mmPART NUMBER Optional Wire HarnessDESCRIPTION Stocked C. Service PartsRED40 at Depot40 in Landscape See-ThruDV Fireplace RED40STRED40,RED40ST #13 Control AssemblyService Parts List #14 Valve Assembly   Service PartsRED40, RED40ST Stocked15.2 #15 Base Pan No Lights with Media15.3 15.115.4 15.215.1 15.316.1 #16 Base Pan With Lights and MediaStocked at Depot 16.316.4 16.216.3 16.1RED40-NNPNo lights, No Rock, Porcelain #17 Base Pan No Lights or Media withPorcelain or No refractory RED40-NNNNo lights, No Rock, No RefractoryRED40ST-NNGNo lights, No Rock, Granite Stocked at DepotRED40ST-NNNNo lights, No Rock, No Refractory RED40ST-NNPNo lights, No Rock, Porcelain#22 Porcelain --With Media #19 Granite --No Media#20 Porcelain --No Media #21 Granite --With Media#21 Granite --With Media NOTES D. Contact Information