15 Troubleshooting

15 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician. Contact your dealer to arrange a service call by a qualified service technician.

A. IntelliFire Ignition System

Symptom

Possible Cause

Corrective Action

 

 

 

1. Pilot won’t light.

a. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor

The ignitor/module

 

are connected to correct terminals on module and pilot assembly.

makes noise, but no

 

 

b. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

spark.

 

shorts in the wiring.

ule to pilot assembly. Verify connections underneath pilot assembly

 

 

are tight; also verify connections are not grounding out to metal

 

 

chassis, pilot burner, pilot enclosure, mesh screen if present, or

 

 

any other metal object.

 

 

 

 

c. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 in. or 1/8 in. (3 mm).

 

 

 

 

d. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place a grounded wire about 3/16 in. (5

 

 

mm) away from “I” terminal on module. Place ON/OFF rocker switch

 

 

or wall switch in ON position. If there is no spark at “I” terminal

 

 

module must be replaced. If there is a spark at “I” terminal, module

 

 

is fine. Inspect pilot assembly for shorted sparker wire or cracked

 

 

insulator around electrode. Replace pilot if necessary.

 

 

 

2. Pilot won’t light,

a. No power or transformer installed

Verify that transformer is installed and plugged into module. Check

there is no noise or

incorrectly.

voltage of transformer under load at spade connection on module

spark.

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

b. A shorted or loose connection in wir-

Remove and reinstall the wiring harness that plugs into module.

 

ing configuration or wiring harness.

Verify there is a tight fit. Verify pilot assembly wiring to module. Re-

 

 

move and verify continuity of each wire in wiring harness. Replace

 

 

any damaged components.

 

 

 

 

c. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

d. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

 

e. Module.

Turn ON/OFF rocker switch or wall switch to OFF position. Re-

 

 

move ignitor wire “I” from module. Place ON/OFF rocker switch

 

 

or wall switch in ON position. If there is no spark at “I” terminal

 

 

module must be replaced. If there is a spark at “I” terminal, module

 

 

is fine. Inspect pilot assembly for shorted sparker wire or cracked

 

 

insulator around electrode.

 

 

 

3. Pilot sparks, but

a. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

Pilot will not light.

 

pressure reading is within acceptable limits.

 

 

 

 

b. Ignitor gap is incorrect.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in (3 mm).

 

 

 

 

c. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

 

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

61

 

Image 61
Contents NOTICE Models RED40 RED40ST•What to do if you smell gas Owner’s ManualHomeowner Reference Information A. CongratulationsSafety Alert Key Table of ContentsInstaller Guide 3 Maintenance and Service15 Troubleshooting 14 Appliance Setup = Contains updated information 13 FinishingLIMITED LIFETIME WARRANTY B. Limited Lifetime WarrantyWARRANTY COVERAGE WARRANTY PERIODWARRANTY CONDITIONS B. Limited Lifetime Warranty continuedWARRANTY EXCLUSIONS This warranty is void if1 Listing and Code Approvals D. High Altitude InstallationsA. Appliance Certification B. Glass SpecificationsInstallation of Carbon Monoxide Detectors 2 Operating Instructions User Guide A. Gas Fireplace SafetyB. Your Fireplace C. Clear SpaceD. Decorative Doors and Fronts E. Fixed Glass AssemblyG. Before Lighting Fireplace erate fireplace with fixed glass assembly removedFinal inspection by H. Lighting Instructions IPIFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS IPII. After Fireplace is Lit J.Frequently Asked QuestionsInitial Break-inProcedure •Some people may be sensitive to smoke and odorsA. Maintenance Tasks-Homeowner 3 Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection B.Maintenance Tasks-QualifiedService TechnicianVenting FireboxA. Typical Appliance System Getting StartedInstaller Guide Figure 4.1 Typical SystemC.Tools and Supplies Needed B. Design and Installation ConsiderationsD. Inspect Appliance and Components A. Selecting Appliance Location 5 Framing and Clearances1/2 IN. C 1/2 INFigure 5.2 Appliance Locations RED40ST C. Clearances B. Constructing the Appliance ChaseMINIMUM FRAMING DIMENSIONS Dimensions of Non-Combustibles D. Mantel and Wall ProjectionsCombustible Mantels Non-CombustibleMantelsA. Vent Termination Minimum Clearances 6 Termination LocationsRoof Pitch H Min. FtCovered Alcove Applications = AREA WHERE TERMINAL IS NOT PERMITTEDV= VENT TERMINAL X = AIR SUPPLY INLET E. Vent Diagrams 7 Vent Information and DiagramsA. Approved Pipe B. Vent Table KeyVenting with 1 elbow Top Vent - Horizontal TerminationV1 Minimum H1 MaximumVenting with 2 elbows 1. Top Vent - Horizontal Termination - continuedINSTALLED HORIZONTALLY H1 + H2 MaximumVenting with 3 elbows 1. Top Vent - Horizontal Terminationcontinued H2 V2 H1 V1V = 3 ft Min. 1m, 50 ft. Max. 15.2 m Top Vent - Vertical Termination No ElbowsExhaust restrictor Instructions V2 H1 V1 Top Vent - Vertical TerminationVenting with 3 elbows DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE A. Pipe Clearances to Combustibles 8 Vent Clearances and FramingB. Wall Penetration Framing Between ceiling firestopsC. Install the Ceiling Firestop Flat Ceiling Installation D. Install Attic Insulation ShieldVaulted Ceiling Installation A. Appliance Preparation 9 Appliance PreparationSetting the Fireplace into the Framing B. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent contact with •Sagging or loose insulationC. Active Convection Technology A. Assemble Vent Sections 10 Installing Vent Pipe DVP PipeC. Secure The Vent Sections B. Assemble Slip SectionsPilot hole D. Disassemble Vent Sections E. Install Decorative Ceiling ComponentsG. Assemble and Install Storm Collar F. Install Metal Roof FlashingCAULK CAUTION! Risk of Cuts, Abrasions or Flying DebrisH. Install Vertical Termination Cap Figure 10.20 Venting Through the Wall J. Install Horizontal Termination CapA. Fuel Conversion 11 Gas InformationB. Gas Pressure •Ensure adequate ventilation C. Gas ConnectionB. IntelliFire Ignition System Wiring A. Wiring RequirementsC. Optional Accessories Requirements 12 Electrical InformationREMOTE RECEIVER Optional Remote Control Receiver LocationSWITCH TRIPPED D. Optional LED Lighting CircuitCOLOR PRODUCED F. Junction Box Installation E. Electrical Service and RepairG. Active Convection Blower Replacement KNOCKOUTFAN MOUNT FASTENER SIDE BURNER SCREWBLOWER TAB ON MOUNTING PLATE SLOT ON BLOWER HOUSINGFigure 12.17. Remove Mounting Plate Figure 12.18. Removed Mounting PlateA. Splatter Guard 13 FinishingB. Framing and Finishing Instructions Finishing InstructionsFinishing Around Opening with Gypsum Wallboard Finish and Sealing JointsPainting Figure 13.1 Finishing DetailsDimensions of Combustibles C. Mantel and Wall ProjectionsFigure 13.5 Framing and Framing Materials-RED40 D. Facing MaterialFigure 13.6 Framing and Framing Materials-RED40ST 0 - 1 inch thickness-OverlapFit Method Non-CombustibleFinish MaterialsFigure 13.7 Overlap Fit Method Figure 13.9 Inside Fit Method 0 Inches to 4 Inches Thick Inside Fit Method42-3/4IN 13-1/8INASSEMBLY E. Mesh FrontsMESH FRAME ASSEMBLY Figure 13.11. Mesh Front InstallationA. Remove Fixed Glass Assembly 14 Appliance SetupC. Clean the Appliance D. AccessoriesI. Install the Mesh H. Fixed Glass AssemblyJ. Air Shutter Setting Removing Fixed Glass AssemblyA. IntelliFire Ignition System 15 TroubleshootingSymptom Possible CauseIntelliFire Ignition System - continued 16 Reference Materials A. Appliance Dimension DiagramM N O P Figure 16.2 Appliance Dimensions RED40STT R Q S A F GFigure 16.2 DVP vent components B. Vent Components DiagramsDVP-AS2 DVP-TRAP1 B. Vent Components Diagrams continuedDVP-TRAP2 DVP-TRAPK131 in 13 in 8-1/8in206 mm 330 mmDESCRIPTION Optional Wire HarnessPART NUMBER RED40 C. Service Partsat Depot Stocked40 in Landscape See-ThruDV Fireplace RED40STService Parts List #13 Control Assembly#14 Valve Assembly RED40,RED40STRED40, RED40ST Service PartsStocked   15.3 #15 Base Pan No Lights with Media15.1 15.215.1 15.215.3 15.4Stocked at Depot #16 Base Pan With Lights and Media16.3 16.116.3 16.216.1 16.4Porcelain or No refractory #17 Base Pan No Lights or Media withRED40-NNNNo lights, No Rock, No Refractory RED40-NNPNo lights, No Rock, PorcelainRED40ST-NNNNo lights, No Rock, No Refractory Stocked at DepotRED40ST-NNPNo lights, No Rock, Porcelain RED40ST-NNGNo lights, No Rock, Granite#20 Porcelain --No Media #19 Granite --No Media#21 Granite --With Media #22 Porcelain --With MediaRED40ST NOTES D. Contact Information