Heat & Glo LifeStyle RED40ST Termination Locations, A. Vent Termination Minimum Clearances

Page 22
6 Termination Locations

6 Termination Locations

A. Vent Termination Minimum Clearances

A. Vent Termination Minimum Clearances WARNING

Fire Risk.

Maintain vent clearance to combustibles as specified.

DO NOT pack air space with insulation or other materials.

Failure to keep insulation or other materials away from vent pipe may cause overheating and fire.

 

 

HORIZONTAL

 

 

OVERHANG

2 FT.

20 INCHES MIN.

VERTICAL

MIN.

 

 

WALL

 

LOWEST

 

 

 

DISCHARGE

 

 

OPENING

 

GAS DIRECT VENT

 

 

TERMINATION CAP

 

 

 

 

X

 

 

12

 

 

ROOF PITCH

 

 

IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

 

H (Min.) Ft.

Flat to 6/12...........................................................1.0*

Over 6/12 to 7/12.................................................1.25*

Over 7/12 to 8/12.................................................1.5*

Over 8/12 to 9/12.................................................2.0*

Over 9/12 to 10/12...............................................2.5

Over 10/12 to 11/12 .............................................3.25

Over 11/12 to 12/12 .............................................4.0

Over 12/12 to 14/12.............................................5.0

Over 14/12 to 16/12.............................................6.0

Over 16/12 to 18/12.............................................7.0

Over 18/12 to 20/12.............................................7.5

Over 20/12 to 21/12.............................................8.0

* 3 foot minimum in snow regions

Figure 6.1 Minimum Height From Roof To Lowest Discharge

Opening

 

 

A

B

6 in. (minimum) up to 20 in.

18 in. minimum

152 mm/508 mm

457 mm

20 in. and over

0 in. minimum

Gas, Wood or Fuel Oil

Termination Cap

B

A *

Gas

Termination

Cap **

*If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

**In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap.

Figure 6.2 Staggered Termination Caps

22

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Image 22
Contents •What to do if you smell gas Models RED40 RED40STNOTICE Owner’s ManualA. Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsSafety Alert Key 3 Maintenance and Service = Contains updated information 14 Appliance Setup15 Troubleshooting 13 FinishingWARRANTY COVERAGE B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY PERIODWARRANTY EXCLUSIONS B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS This warranty is void ifA. Appliance Certification D. High Altitude Installations1 Listing and Code Approvals B. Glass SpecificationsInstallation of Carbon Monoxide Detectors B. Your Fireplace A. Gas Fireplace Safety2 Operating Instructions User Guide C. Clear SpaceG. Before Lighting Fireplace E. Fixed Glass AssemblyD. Decorative Doors and Fronts erate fireplace with fixed glass assembly removedFOR YOUR SAFETY READ BEFORE LIGHTING H. Lighting Instructions IPIFinal inspection by LIGHTING INSTRUCTIONS IPIInitial Break-inProcedure J.Frequently Asked QuestionsI. After Fireplace is Lit •Some people may be sensitive to smoke and odorsGlass Cleaning 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Remote ControlVenting B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection FireboxInstaller Guide Getting StartedA. Typical Appliance System Figure 4.1 Typical SystemC.Tools and Supplies Needed B. Design and Installation ConsiderationsD. Inspect Appliance and Components 5 Framing and Clearances A. Selecting Appliance Location1/2 IN. C 1/2 INFigure 5.2 Appliance Locations RED40ST B. Constructing the Appliance Chase C. ClearancesMINIMUM FRAMING DIMENSIONS Combustible Mantels D. Mantel and Wall ProjectionsDimensions of Non-Combustibles Non-CombustibleMantelsRoof Pitch 6 Termination LocationsA. Vent Termination Minimum Clearances H Min. FtCovered Alcove Applications = AREA WHERE TERMINAL IS NOT PERMITTEDV= VENT TERMINAL X = AIR SUPPLY INLET A. Approved Pipe 7 Vent Information and DiagramsE. Vent Diagrams B. Vent Table KeyV1 Minimum Top Vent - Horizontal TerminationVenting with 1 elbow H1 MaximumINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows H1 + H2 Maximumcontinued 1. Top Vent - Horizontal TerminationVenting with 3 elbows H2 V2 H1 V1V = 3 ft Min. 1m, 50 ft. Max. 15.2 m Top Vent - Vertical Termination No ElbowsExhaust restrictor Instructions Top Vent - Vertical Termination V2 H1 V1V1 + V2 Minimum DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE B. Wall Penetration Framing 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles Between ceiling firestopsC. Install the Ceiling Firestop Flat Ceiling Installation D. Install Attic Insulation ShieldVaulted Ceiling Installation 9 Appliance Preparation A. Appliance PreparationWARNING! Risk of Fire! Prevent contact with B. Securing and Leveling the ApplianceSetting the Fireplace into the Framing •Sagging or loose insulationC. Active Convection Technology 10 Installing Vent Pipe DVP Pipe A. Assemble Vent SectionsC. Secure The Vent Sections B. Assemble Slip SectionsPilot hole E. Install Decorative Ceiling Components D. Disassemble Vent SectionsCAULK F. Install Metal Roof FlashingG. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying DebrisH. Install Vertical Termination Cap J. Install Horizontal Termination Cap Figure 10.20 Venting Through the WallA. Fuel Conversion 11 Gas InformationB. Gas Pressure C. Gas Connection •Ensure adequate ventilationC. Optional Accessories Requirements A. Wiring RequirementsB. IntelliFire Ignition System Wiring 12 Electrical InformationOptional Remote Control Receiver Location REMOTE RECEIVERSWITCH TRIPPED D. Optional LED Lighting CircuitCOLOR PRODUCED G. Active Convection Blower Replacement E. Electrical Service and RepairF. Junction Box Installation KNOCKOUTSIDE BURNER SCREW FAN MOUNT FASTENERFigure 12.17. Remove Mounting Plate SLOT ON BLOWER HOUSINGBLOWER TAB ON MOUNTING PLATE Figure 12.18. Removed Mounting PlateB. Framing and Finishing Instructions 13 FinishingA. Splatter Guard Finishing InstructionsPainting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Figure 13.1 Finishing DetailsC. Mantel and Wall Projections Dimensions of CombustiblesFigure 13.5 Framing and Framing Materials-RED40 D. Facing MaterialFigure 13.6 Framing and Framing Materials-RED40ST 0 - 1 inch thickness-OverlapFit Method Non-CombustibleFinish MaterialsFigure 13.7 Overlap Fit Method 42-3/4IN 0 Inches to 4 Inches Thick Inside Fit MethodFigure 13.9 Inside Fit Method 13-1/8INMESH FRAME ASSEMBLY E. Mesh FrontsASSEMBLY Figure 13.11. Mesh Front InstallationC. Clean the Appliance 14 Appliance SetupA. Remove Fixed Glass Assembly D. AccessoriesJ. Air Shutter Setting H. Fixed Glass AssemblyI. Install the Mesh Removing Fixed Glass AssemblySymptom 15 TroubleshootingA. IntelliFire Ignition System Possible CauseIntelliFire Ignition System - continued A. Appliance Dimension Diagram 16 Reference MaterialsT R Q S Figure 16.2 Appliance Dimensions RED40STM N O P A F GFigure 16.2 DVP vent components B. Vent Components DiagramsDVP-AS2 DVP-TRAP2 B. Vent Components Diagrams continuedDVP-TRAP1 DVP-TRAPK131 in 206 mm 8-1/8in13 in 330 mmDESCRIPTION Optional Wire HarnessPART NUMBER at Depot C. Service PartsRED40 StockedRED40ST 40 in Landscape See-ThruDV Fireplace#14 Valve Assembly #13 Control AssemblyService Parts List RED40,RED40STStocked Service PartsRED40, RED40ST   15.1 #15 Base Pan No Lights with Media15.3 15.215.3 15.215.1 15.416.3 #16 Base Pan With Lights and MediaStocked at Depot 16.116.1 16.216.3 16.4RED40-NNNNo lights, No Rock, No Refractory #17 Base Pan No Lights or Media withPorcelain or No refractory RED40-NNPNo lights, No Rock, PorcelainRED40ST-NNPNo lights, No Rock, Porcelain Stocked at DepotRED40ST-NNNNo lights, No Rock, No Refractory RED40ST-NNGNo lights, No Rock, Granite#21 Granite --With Media #19 Granite --No Media#20 Porcelain --No Media #22 Porcelain --With Media#19 Granite --No Media D. Contact Information NOTES