Heat & Glo LifeStyle RED40ST H. Fixed Glass Assembly, I. Install the Mesh, J. Air Shutter Setting

Page 60
H. Fixed Glass Assembly

H. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

1.Remove the decorative front.

2.Locate the two spring latches that are on the lower left and right of the fireplace.

3.Use both index fingers to release spring latches. See Figure 14.3.

4.Allow glass to tilt forward. Grasp glass on the upper return lip of glass frame and tilt glass “out” and “down”. Lower gently to rest on side supports. See Figure 14.3. Allow top of glass assembly to tilt forward. Lift glass assembly “up” and “out”.

Replacing Fixed Glass Assembly

1.Locate glide tabs on lower left and right corners.

2.Place glass bottom resting on right and left support. Tilt top of glass assembly toward fireplace.

3.Allow of the gasketing of the glass assembly to touch the face of the fireplace. Lift the glass “up” and “in” to upper glass clip flanges.

4.Hold bottom of the glass as you allow the glass as- sembly to seat over the two lower glass clips. See Figure 14.3.

5.Assure proper left and right placement of glass and engage both lower spring latches.

GLASS SIDE

SUPPORT

GLASS CLIP

GLASS TAB

Figure 14.3 Fixed Glass Assembly

I. Install the Mesh

A mesh front is included with the RED40 and RED40ST. For installation instructions, see section 13.D.

J. Air Shutter Setting

Air shutter settings may be adjusted by a qualified install- er at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.4.

Loosen the 1/4 in. screw.

Twist shutter to adjust

Shutter may be open for longer horizontal vent runs.

Do not close the air shutter more than 1/16 in. for NG or 1/4 in. for LP.

Tighten the screw.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

Figure 14.4 Air Shutter

Air Shutter Settings

RED40/RED40ST

NG

LP

GRANITE KIT

1/16 in.

1/4 in.

LIGHT KIT

1/16 in.

1/4 in.

PORCELAIN KIT

1/16 in.

1/4 in.

60

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Image 60
Contents Models RED40 RED40ST NOTICE•What to do if you smell gas Owner’s ManualA. Congratulations Homeowner Reference InformationTable of Contents Safety Alert KeyInstaller Guide 3 Maintenance and Service14 Appliance Setup 15 Troubleshooting = Contains updated information 13 FinishingB. Limited Lifetime Warranty LIMITED LIFETIME WARRANTYWARRANTY COVERAGE WARRANTY PERIODB. Limited Lifetime Warranty continued WARRANTY CONDITIONSWARRANTY EXCLUSIONS This warranty is void ifD. High Altitude Installations 1 Listing and Code ApprovalsA. Appliance Certification B. Glass SpecificationsInstallation of Carbon Monoxide Detectors A. Gas Fireplace Safety 2 Operating Instructions User GuideB. Your Fireplace C. Clear SpaceE. Fixed Glass Assembly D. Decorative Doors and FrontsG. Before Lighting Fireplace erate fireplace with fixed glass assembly removedH. Lighting Instructions IPI Final inspection byFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS IPIJ.Frequently Asked Questions I. After Fireplace is LitInitial Break-inProcedure •Some people may be sensitive to smoke and odors3 Maintenance and Service A. Maintenance Tasks-HomeownerGlass Cleaning Remote ControlB.Maintenance Tasks-QualifiedService Technician Gasket Seal and Glass Assembly InspectionVenting FireboxGetting Started A. Typical Appliance SystemInstaller Guide Figure 4.1 Typical SystemB. Design and Installation Considerations C.Tools and Supplies NeededD. Inspect Appliance and Components 5 Framing and Clearances A. Selecting Appliance Location1/2 IN 1/2 IN. CFigure 5.2 Appliance Locations RED40ST B. Constructing the Appliance Chase C. ClearancesMINIMUM FRAMING DIMENSIONS D. Mantel and Wall Projections Dimensions of Non-CombustiblesCombustible Mantels Non-CombustibleMantels6 Termination Locations A. Vent Termination Minimum ClearancesRoof Pitch H Min. Ft= AREA WHERE TERMINAL IS NOT PERMITTED Covered Alcove ApplicationsV= VENT TERMINAL X = AIR SUPPLY INLET 7 Vent Information and Diagrams E. Vent DiagramsA. Approved Pipe B. Vent Table KeyTop Vent - Horizontal Termination Venting with 1 elbowV1 Minimum H1 Maximum1. Top Vent - Horizontal Termination - continued Venting with 2 elbowsINSTALLED HORIZONTALLY H1 + H2 Maximum1. Top Vent - Horizontal Termination Venting with 3 elbowscontinued H2 V2 H1 V1Top Vent - Vertical Termination No Elbows V = 3 ft Min. 1m, 50 ft. Max. 15.2 mExhaust restrictor Instructions Top Vent - Vertical Termination V2 H1 V1Top Vent - Vertical Termination DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE 8 Vent Clearances and Framing A. Pipe Clearances to CombustiblesB. Wall Penetration Framing Between ceiling firestopsC. Install the Ceiling Firestop D. Install Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation 9 Appliance Preparation A. Appliance PreparationB. Securing and Leveling the Appliance Setting the Fireplace into the FramingWARNING! Risk of Fire! Prevent contact with •Sagging or loose insulationC. Active Convection Technology 10 Installing Vent Pipe DVP Pipe A. Assemble Vent SectionsB. Assemble Slip Sections C. Secure The Vent SectionsPilot hole E. Install Decorative Ceiling Components D. Disassemble Vent SectionsF. Install Metal Roof Flashing G. Assemble and Install Storm CollarCAULK CAUTION! Risk of Cuts, Abrasions or Flying DebrisH. Install Vertical Termination Cap J. Install Horizontal Termination Cap Figure 10.20 Venting Through the Wall11 Gas Information A. Fuel ConversionB. Gas Pressure C. Gas Connection •Ensure adequate ventilationA. Wiring Requirements B. IntelliFire Ignition System WiringC. Optional Accessories Requirements 12 Electrical InformationOptional Remote Control Receiver Location REMOTE RECEIVERD. Optional LED Lighting Circuit SWITCH TRIPPEDCOLOR PRODUCED E. Electrical Service and Repair F. Junction Box InstallationG. Active Convection Blower Replacement KNOCKOUTSIDE BURNER SCREW FAN MOUNT FASTENERSLOT ON BLOWER HOUSING BLOWER TAB ON MOUNTING PLATEFigure 12.17. Remove Mounting Plate Figure 12.18. Removed Mounting Plate13 Finishing A. Splatter GuardB. Framing and Finishing Instructions Finishing InstructionsFinish and Sealing Joints Finishing Around Opening with Gypsum WallboardPainting Figure 13.1 Finishing DetailsC. Mantel and Wall Projections Dimensions of CombustiblesD. Facing Material Figure 13.5 Framing and Framing Materials-RED40Figure 13.6 Framing and Framing Materials-RED40ST Non-CombustibleFinish Materials 0 - 1 inch thickness-OverlapFit MethodFigure 13.7 Overlap Fit Method 0 Inches to 4 Inches Thick Inside Fit Method Figure 13.9 Inside Fit Method42-3/4IN 13-1/8INE. Mesh Fronts ASSEMBLYMESH FRAME ASSEMBLY Figure 13.11. Mesh Front Installation14 Appliance Setup A. Remove Fixed Glass AssemblyC. Clean the Appliance D. AccessoriesH. Fixed Glass Assembly I. Install the MeshJ. Air Shutter Setting Removing Fixed Glass Assembly15 Troubleshooting A. IntelliFire Ignition SystemSymptom Possible CauseIntelliFire Ignition System - continued A. Appliance Dimension Diagram 16 Reference MaterialsFigure 16.2 Appliance Dimensions RED40ST M N O PT R Q S A F GB. Vent Components Diagrams Figure 16.2 DVP vent componentsDVP-AS2 B. Vent Components Diagrams continued DVP-TRAP1DVP-TRAP2 DVP-TRAPK131 in 8-1/8in 13 in206 mm 330 mmOptional Wire Harness DESCRIPTIONPART NUMBER C. Service Parts RED40at Depot StockedRED40ST 40 in Landscape See-ThruDV Fireplace#13 Control Assembly Service Parts List#14 Valve Assembly RED40,RED40STService Parts RED40, RED40STStocked   #15 Base Pan No Lights with Media 15.315.1 15.215.2 15.115.3 15.4#16 Base Pan With Lights and Media Stocked at Depot16.3 16.116.2 16.316.1 16.4#17 Base Pan No Lights or Media with Porcelain or No refractoryRED40-NNNNo lights, No Rock, No Refractory RED40-NNPNo lights, No Rock, PorcelainStocked at Depot RED40ST-NNNNo lights, No Rock, No RefractoryRED40ST-NNPNo lights, No Rock, Porcelain RED40ST-NNGNo lights, No Rock, Granite#19 Granite --No Media #20 Porcelain --No Media#21 Granite --With Media #22 Porcelain --With MediaService Parts D. Contact Information NOTES