Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces. The Heat & Glo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas fireplace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your fireplace.

Model Name: ___________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on fireplace: _____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.

Type of Gas

Gas and Electric Information

Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215th Street West, Lakeville, MN 55044

Not for use with solid fuel.

(Ne doit pas entre utilise avec un combustible solide).

Type of Gas (Sorte De Gaz): This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1 in the USA or CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglements locaux ou, en l’absence de tels reglements, selon les codes d’installation CAN/CGA-B149.)

ANSI Z21XX-XXXX · CSA 2.XX-MXX · UL307B

Minimum Permissible Gas Supply for Purposes of Input Adjustment.

 

 

 

Approved Minimum (De Gaz) Acceptable

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Pressure (Pression)

 

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Minimum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes

MADE IN USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN CANADA

 

Model:

XXXXXXXX

 

ALTITUDE:

0-0000 FT.

0000-0000FT.

 

(Modele):

 

MAX. INPUT BTUH:

00,000

00,000

 

 

 

 

 

 

 

MIN. INPUT BTUH:

00,000

00,000

 

Serial

XXXXXXXX

 

ORIFICE SIZE:

#XXXXX

#XXXXX

 

 

 

(Serie):

 

Model Number

Serial Number

2

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Image 2
Contents •What to do if you smell gas Models RED40 RED40STNOTICE Owner’s ManualA. Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsSafety Alert Key 3 Maintenance and Service = Contains updated information 14 Appliance Setup15 Troubleshooting 13 FinishingWARRANTY COVERAGE B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY PERIODWARRANTY EXCLUSIONS B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS This warranty is void ifA. Appliance Certification D. High Altitude Installations1 Listing and Code Approvals B. Glass SpecificationsInstallation of Carbon Monoxide Detectors B. Your Fireplace A. Gas Fireplace Safety2 Operating Instructions User Guide C. Clear SpaceG. Before Lighting Fireplace E. Fixed Glass AssemblyD. Decorative Doors and Fronts erate fireplace with fixed glass assembly removedFOR YOUR SAFETY READ BEFORE LIGHTING H. Lighting Instructions IPIFinal inspection by LIGHTING INSTRUCTIONS IPIInitial Break-inProcedure J.Frequently Asked QuestionsI. After Fireplace is Lit •Some people may be sensitive to smoke and odorsGlass Cleaning 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Remote ControlVenting B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection FireboxInstaller Guide Getting StartedA. Typical Appliance System Figure 4.1 Typical SystemD. Inspect Appliance and Components B. Design and Installation ConsiderationsC.Tools and Supplies Needed 5 Framing and Clearances A. Selecting Appliance LocationFigure 5.2 Appliance Locations RED40ST 1/2 IN1/2 IN. C B. Constructing the Appliance Chase C. ClearancesMINIMUM FRAMING DIMENSIONS Combustible Mantels D. Mantel and Wall ProjectionsDimensions of Non-Combustibles Non-CombustibleMantelsRoof Pitch 6 Termination LocationsA. Vent Termination Minimum Clearances H Min. FtV= VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDCovered Alcove Applications A. Approved Pipe 7 Vent Information and DiagramsE. Vent Diagrams B. Vent Table KeyV1 Minimum Top Vent - Horizontal TerminationVenting with 1 elbow H1 MaximumINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows H1 + H2 Maximumcontinued 1. Top Vent - Horizontal TerminationVenting with 3 elbows H2 V2 H1 V1Exhaust restrictor Instructions Top Vent - Vertical Termination No ElbowsV = 3 ft Min. 1m, 50 ft. Max. 15.2 m Top Vent - Vertical Termination V2 H1 V1V1 + V2 Minimum DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE B. Wall Penetration Framing 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles Between ceiling firestopsC. Install the Ceiling Firestop Vaulted Ceiling Installation D. Install Attic Insulation ShieldFlat Ceiling Installation 9 Appliance Preparation A. Appliance PreparationWARNING! Risk of Fire! Prevent contact with B. Securing and Leveling the ApplianceSetting the Fireplace into the Framing •Sagging or loose insulationC. Active Convection Technology 10 Installing Vent Pipe DVP Pipe A. Assemble Vent SectionsPilot hole B. Assemble Slip SectionsC. Secure The Vent Sections E. Install Decorative Ceiling Components D. Disassemble Vent SectionsCAULK F. Install Metal Roof FlashingG. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying DebrisH. Install Vertical Termination Cap J. Install Horizontal Termination Cap Figure 10.20 Venting Through the WallB. Gas Pressure 11 Gas InformationA. Fuel Conversion C. Gas Connection •Ensure adequate ventilationC. Optional Accessories Requirements A. Wiring RequirementsB. IntelliFire Ignition System Wiring 12 Electrical InformationOptional Remote Control Receiver Location REMOTE RECEIVERCOLOR PRODUCED D. Optional LED Lighting CircuitSWITCH TRIPPED G. Active Convection Blower Replacement E. Electrical Service and RepairF. Junction Box Installation KNOCKOUTSIDE BURNER SCREW FAN MOUNT FASTENERFigure 12.17. Remove Mounting Plate SLOT ON BLOWER HOUSINGBLOWER TAB ON MOUNTING PLATE Figure 12.18. Removed Mounting PlateB. Framing and Finishing Instructions 13 FinishingA. Splatter Guard Finishing InstructionsPainting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Figure 13.1 Finishing DetailsC. Mantel and Wall Projections Dimensions of CombustiblesFigure 13.6 Framing and Framing Materials-RED40ST D. Facing MaterialFigure 13.5 Framing and Framing Materials-RED40 Figure 13.7 Overlap Fit Method Non-CombustibleFinish Materials0 - 1 inch thickness-OverlapFit Method 42-3/4IN 0 Inches to 4 Inches Thick Inside Fit MethodFigure 13.9 Inside Fit Method 13-1/8INMESH FRAME ASSEMBLY E. Mesh FrontsASSEMBLY Figure 13.11. Mesh Front InstallationC. Clean the Appliance 14 Appliance SetupA. Remove Fixed Glass Assembly D. AccessoriesJ. Air Shutter Setting H. Fixed Glass AssemblyI. Install the Mesh Removing Fixed Glass AssemblySymptom 15 TroubleshootingA. IntelliFire Ignition System Possible CauseIntelliFire Ignition System - continued A. Appliance Dimension Diagram 16 Reference MaterialsT R Q S Figure 16.2 Appliance Dimensions RED40STM N O P A F GDVP-AS2 B. Vent Components DiagramsFigure 16.2 DVP vent components DVP-TRAP2 B. Vent Components Diagrams continuedDVP-TRAP1 DVP-TRAPK131 in 206 mm 8-1/8in13 in 330 mmPART NUMBER Optional Wire HarnessDESCRIPTION at Depot C. Service PartsRED40 StockedRED40ST 40 in Landscape See-ThruDV Fireplace#14 Valve Assembly #13 Control AssemblyService Parts List RED40,RED40STStocked Service PartsRED40, RED40ST   15.1 #15 Base Pan No Lights with Media15.3 15.215.3 15.215.1 15.416.3 #16 Base Pan With Lights and MediaStocked at Depot 16.116.1 16.216.3 16.4RED40-NNNNo lights, No Rock, No Refractory #17 Base Pan No Lights or Media withPorcelain or No refractory RED40-NNPNo lights, No Rock, PorcelainRED40ST-NNPNo lights, No Rock, Porcelain Stocked at DepotRED40ST-NNNNo lights, No Rock, No Refractory RED40ST-NNGNo lights, No Rock, Granite#21 Granite --With Media #19 Granite --No Media#20 Porcelain --No Media #22 Porcelain --With Media#19 Granite --No Media D. Contact Information NOTES