Heat & Glo LifeStyle RED40ST E. Mesh Fronts, Mesh Brackets, Mesh Frame, Assembly, Hanging Tabs

Page 58
E. Mesh Fronts

E. Mesh Fronts

WARNING! Risk of Burns! A decorative front is required for this model. DO NOT operate this appliance without a decorative front in place.

Only doors certified for use with this appliance model may be used. Contact your dealer for a list of doors that may be used.

A mesh front is included with the RED40 and RED40ST.

To attach the mesh front to the appliance, use the two mesh brackets. These brackets are mounted to the un- derside of the top of the appliance viewing area and are fastened to the appliance by two screws on each bracket. See Figure 13.11. There are two hanging tabs on the back of the mesh front assembly that are bent upward. Engage these tabs in the slot of the brackets.

MESH BRACKETS

MESH FRAME

ASSEMBLY

HANGING TABS

MESH FRAME ASSEMBLY

Figure 13.11. Mesh Front Installation.

58

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Image 58
Contents •What to do if you smell gas Models RED40 RED40STNOTICE Owner’s ManualA. Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsSafety Alert Key 3 Maintenance and Service = Contains updated information 14 Appliance Setup15 Troubleshooting 13 FinishingWARRANTY COVERAGE B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY PERIODWARRANTY EXCLUSIONS B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS This warranty is void ifA. Appliance Certification D. High Altitude Installations1 Listing and Code Approvals B. Glass SpecificationsInstallation of Carbon Monoxide Detectors B. Your Fireplace A. Gas Fireplace Safety2 Operating Instructions User Guide C. Clear SpaceG. Before Lighting Fireplace E. Fixed Glass AssemblyD. Decorative Doors and Fronts erate fireplace with fixed glass assembly removedFOR YOUR SAFETY READ BEFORE LIGHTING H. Lighting Instructions IPIFinal inspection by LIGHTING INSTRUCTIONS IPIInitial Break-inProcedure J.Frequently Asked QuestionsI. After Fireplace is Lit •Some people may be sensitive to smoke and odorsGlass Cleaning 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Remote ControlVenting B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection FireboxInstaller Guide Getting StartedA. Typical Appliance System Figure 4.1 Typical SystemC.Tools and Supplies Needed B. Design and Installation ConsiderationsD. Inspect Appliance and Components 5 Framing and Clearances A. Selecting Appliance Location1/2 IN. C 1/2 INFigure 5.2 Appliance Locations RED40ST B. Constructing the Appliance Chase C. ClearancesMINIMUM FRAMING DIMENSIONS Combustible Mantels D. Mantel and Wall ProjectionsDimensions of Non-Combustibles Non-CombustibleMantelsRoof Pitch 6 Termination LocationsA. Vent Termination Minimum Clearances H Min. FtCovered Alcove Applications = AREA WHERE TERMINAL IS NOT PERMITTEDV= VENT TERMINAL X = AIR SUPPLY INLET A. Approved Pipe 7 Vent Information and DiagramsE. Vent Diagrams B. Vent Table KeyV1 Minimum Top Vent - Horizontal TerminationVenting with 1 elbow H1 MaximumINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows H1 + H2 Maximumcontinued 1. Top Vent - Horizontal TerminationVenting with 3 elbows H2 V2 H1 V1V = 3 ft Min. 1m, 50 ft. Max. 15.2 m Top Vent - Vertical Termination No ElbowsExhaust restrictor Instructions Top Vent - Vertical Termination V2 H1 V1V1 + V2 Minimum DIRECT VENT WITH 5 in. / 8 in. DIAMETER DVP PIPE B. Wall Penetration Framing 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles Between ceiling firestopsC. Install the Ceiling Firestop Flat Ceiling Installation D. Install Attic Insulation ShieldVaulted Ceiling Installation 9 Appliance Preparation A. Appliance PreparationWARNING! Risk of Fire! Prevent contact with B. Securing and Leveling the ApplianceSetting the Fireplace into the Framing •Sagging or loose insulationC. Active Convection Technology 10 Installing Vent Pipe DVP Pipe A. Assemble Vent SectionsC. Secure The Vent Sections B. Assemble Slip SectionsPilot hole E. Install Decorative Ceiling Components D. Disassemble Vent SectionsCAULK F. Install Metal Roof FlashingG. Assemble and Install Storm Collar CAUTION! Risk of Cuts, Abrasions or Flying DebrisH. Install Vertical Termination Cap J. Install Horizontal Termination Cap Figure 10.20 Venting Through the WallA. Fuel Conversion 11 Gas InformationB. Gas Pressure C. Gas Connection •Ensure adequate ventilationC. Optional Accessories Requirements A. Wiring RequirementsB. IntelliFire Ignition System Wiring 12 Electrical InformationOptional Remote Control Receiver Location REMOTE RECEIVERSWITCH TRIPPED D. Optional LED Lighting CircuitCOLOR PRODUCED G. Active Convection Blower Replacement E. Electrical Service and RepairF. Junction Box Installation KNOCKOUTSIDE BURNER SCREW FAN MOUNT FASTENERFigure 12.17. Remove Mounting Plate SLOT ON BLOWER HOUSINGBLOWER TAB ON MOUNTING PLATE Figure 12.18. Removed Mounting PlateB. Framing and Finishing Instructions 13 FinishingA. Splatter Guard Finishing InstructionsPainting Finish and Sealing JointsFinishing Around Opening with Gypsum Wallboard Figure 13.1 Finishing DetailsC. Mantel and Wall Projections Dimensions of CombustiblesFigure 13.5 Framing and Framing Materials-RED40 D. Facing MaterialFigure 13.6 Framing and Framing Materials-RED40ST 0 - 1 inch thickness-OverlapFit Method Non-CombustibleFinish MaterialsFigure 13.7 Overlap Fit Method 42-3/4IN 0 Inches to 4 Inches Thick Inside Fit MethodFigure 13.9 Inside Fit Method 13-1/8INMESH FRAME ASSEMBLY E. Mesh FrontsASSEMBLY Figure 13.11. Mesh Front InstallationC. Clean the Appliance 14 Appliance SetupA. Remove Fixed Glass Assembly D. AccessoriesJ. Air Shutter Setting H. Fixed Glass AssemblyI. Install the Mesh Removing Fixed Glass AssemblySymptom 15 TroubleshootingA. IntelliFire Ignition System Possible CauseIntelliFire Ignition System - continued A. Appliance Dimension Diagram 16 Reference MaterialsT R Q S Figure 16.2 Appliance Dimensions RED40STM N O P A F GFigure 16.2 DVP vent components B. Vent Components DiagramsDVP-AS2 DVP-TRAP2 B. Vent Components Diagrams continuedDVP-TRAP1 DVP-TRAPK131 in 206 mm 8-1/8in13 in 330 mmDESCRIPTION Optional Wire HarnessPART NUMBER at Depot C. Service PartsRED40 StockedRED40ST 40 in Landscape See-ThruDV Fireplace#14 Valve Assembly #13 Control AssemblyService Parts List RED40,RED40STStocked Service PartsRED40, RED40ST   15.1 #15 Base Pan No Lights with Media15.3 15.215.3 15.215.1 15.416.3 #16 Base Pan With Lights and MediaStocked at Depot 16.116.1 16.216.3 16.4RED40-NNNNo lights, No Rock, No Refractory #17 Base Pan No Lights or Media withPorcelain or No refractory RED40-NNPNo lights, No Rock, PorcelainRED40ST-NNPNo lights, No Rock, Porcelain Stocked at DepotRED40ST-NNNNo lights, No Rock, No Refractory RED40ST-NNGNo lights, No Rock, Granite#21 Granite --With Media #19 Granite --No Media#20 Porcelain --No Media #22 Porcelain --With Media#19 Granite --No Media D. Contact Information NOTES