Heat & Glo LifeStyle 6000C manual For Your Safety Read Before Lighting Lighting Instructions

Page 14

L. Lighting Instructions (Standing Pilot)

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING INSTRUCTIONS

1.

Open control access panel.

2.

Turn off all electric power to

 

the appliance.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, DO NOT try to repair it, call a qualified service technician. Force or attempted repair may re- sult in a fire or explosion.

D.DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

3. Push in gas control knob

slightly and turn clockwise

to “OFF”.

Note: Knob cannot be turned from “PILOT” to “OFF” unless knob is pushed in slightly. DO NOT force.

4.Open the fixed glass assembly. You may need to remove the decorative front.

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell

gas, STOP! Follow “B” in the Safety Information located on the left side of this label. If you don’t smell gas, go to next step.

6. Find the pilot. The pilot is inside combustion chamber next to the main burner

7.

Turn knob on gas control counterclockwise

 

to “PILOT”.

8.

Push in control knob all the way and hold in. Immedi-

WARNING: CAUTION:

ately depress red or black piezo button. It may require

several depressions of the red or black piezo button

until PILOT lights. If PILOT light does not light after

10 seconds, return to step 3. Continue to hold the

DO NOT CONNECT 110 VAC TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the man- ufacturer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproductive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

DO NOT operate the appliance with fixed glass assembly removed, cracked or broken. Replacement of the fixed glass assembly should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

control knob in for about one minute after the pilot is

lit. Release knob and it will pop back out. Pilot should

remain lit. If it goes out, repeat steps 3 through 6.

If knob does not pop up when released, stop and

immediately call your service technician or gas

supplier.

If the pilot will not stay lit after several tries, turn

the gas control knob to “OFF” and call your ser-

vice technician or gas supplier.

9. Reinstall fixed glass assembly. Reinstall decorative

front.

10. Turn gas control knob counterclockwise

to “ON”. Close access panel.

11. Turn on all electric power to the appliance.

12. To light burner, turn the wall control or on/off switch

to “ON”.

TO TURN OFF

GAS TO APPLIANCE

1.

Turn off all electric power to the appliance if ser-

 

vice is to be performed.

2.

Open control access panel.

3.

Move switch to “OFF” position.

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Final inspection by

4.

Push in gas control knob slightly and turn clock-

 

wise

to OFF”. DO NOT force.

5.

Close control access panel.

464-903H

14

Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI2164-900 Rev. T • 9/12

Image 14
Contents Hot glass will cause burns What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyLimited Lifetime Warranty Warranty ConditionsHigh Altitude Installations Tempered Glass SpecificationsBTU Specifications Listing and Code ApprovalsElectrical Codes Non-Combustible Materials SpecificationCombustible Materials Specification C22.1Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceNine Hour Safety Shutdown Feature IPI Battery Tray/Battery InstallationModule Reset Control Module OperationWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsRefractory, Grate and Valve Assembly Removal Base RefractoryBurner Identification/Verification Notch LocationGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Any such action may cause a fire hazard6000 Framing and ClearancesSelecting Appliance Location 80006000 Constructing the Appliance ChaseClearances 8000Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications = 9 inches U.S.AVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsVent pipe, if desired Vent Diagrams Top Vent Horizontal TerminationOne Elbow 6000C-IPI 8000C-IPI V1 Minimum H1 Maximum6000C-IPI V1 Minimum H1 + H2 Maximum Top Vent Horizontal Termination Two ElbowsThree Elbows 8000C-IPI V1 Minimum H1 + H2 MaximumBreak Top Vent Vertical Termination Maximum + V 2 MinTop Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumPage H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H1 + H2 Maximum Minimum + H Maximum Rear Vent Vertical Termination One ElbowV1 Minimum H1 Maximum Rear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3 Maximum 10 ftClearances to Combustibles Prior to installing the gas applianceCoaxial to Colinear Venting Termination Cap Flue DamperRear Vent Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit Vaulted Ceiling InstallationAppliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outHeader Installing the Non-combustible BoardSecuring and Leveling the Appliance Assemble Vent Sections DVP Pipe Only Installing Vent Pipe DVP and SLP PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Roof Pitch Min. Ft Install Metal Roof FlashingAssemble and Install Storm Collar Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Pressure Gas InformationFuel Conversion Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntelliFire Plus Ignition System Wiring Optional Accessories RequirementsTo Junction Electrical Service and Repair Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialDoor FIT Finish Material See Thickness DoorsFinishing Material Inch Thick or Less Models Finishing Material Thickness 1-4 inches maximumFinishing Material Thickness 0-4 inches maximum Removal of Finishing Strips Finishing Strips RemovedElevated Hearth Systems Appliance Setup Bottom view Logs # 2 Install the Log Assembly Log Assembly LOGS-6C6000C, 6000C-IPI LOG Contacts Grate Tines Install the Log Assembly Log Assembly LOGS-8C 8000C-IPILP, 8000CBV-IPIHorizontal Grate BAR Air Shutter Settings Install Trim and/or SurroundAir Shutter Setting 6000 8000Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemLocation Inches Millimeters Appliance Dimension DiagramReference Materials GAS Line Access R Left Side TOP View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP Horizontal Termination CapDVP-TRAPFL RF6M RF12MBEK DVP-BEK2 COOL-ADDMDVP-TVHW DVP-FBHTPVI-SLP Optional Wire HarnessPower Vent Inline SLP-LPCDV-46DVA-GCL DVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAPLINK-DV30B DVP-2SL AdapterSLP Pipe SLP45SLP90 DVP-SLP24SLP-WT-BK SLP-TRAPDVP-2SL SLP-DCF-BK SLP-CCS-BKSLK-SNKD SLP-TVHWGas Fireplace DV Service PartsAt Depot Beginning Manufacturing Date Aug8000C, 8000C-IPI 6000C-IPI 8000C-IPI8000C Stocked6000C Standing Pilot Conversion Kits IPI Conversion KitsContact Information