Heat & Glo LifeStyle 6000C manual Troubleshooting, Symptom Possible Cause Corrective Action

Page 68

Troubleshooting (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. (Continued)

C. Valve.

Turn the valve knob to the ON position. Place the ON/

 

 

OFF switch in the ON position. Take a reading with a

 

 

millivolt meter at the thermopile terminals. The millivolt

 

 

meter should read greater than 125mV. If the reading

 

 

is acceptable, and if the burner does not come on, re-

 

 

place the gas valve.

 

 

 

 

D. Plugged burner orifice.

Check the burner orifice for stoppage. Remove stop-

 

 

page.

 

 

 

 

E. Wall switch or wires.

Check the wall switch and wires for proper connec-

 

 

tions. Place the jumper wires across the terminals at

 

 

the wall switch. If the burner comes on, replace the

 

 

wall switch. If the wall switch is OK, place the jumper

 

 

wires across the wall switch wires at the gas valve. If

 

 

the burner comes on, the wires are faulty or connec-

 

 

tions are bad.

 

 

 

4. Frequent pilot outage

A. Pilot flame may be too high or too low, or blow-

Clean thermocouple and adjust the pilot flame for

problem.

ing out (high pressure), causing pilot safety to

proper flame impingement. Follow lighting instructions

 

drop out.

carefully.

 

 

 

5. The pilot and main

A. No LP in tank.

Check the LP (propane) tank. Refill the fuel tank.

burner extinguish

 

 

B. Improper gas inlet pressure.

Natural gas should be 5-10 in. w.c. LP should be 11-13

while in operation.

 

in. w.c. Verify pressure with manometer.

 

 

 

 

 

 

C. Inner vent pipe leaking exhaust gases back

Check venting system for damage. Replace/repair im-

 

into the system.

properly assembled pipe sections.

 

 

 

 

D. Glass installed improperly.

Check to ensure glass is installed properly. Replace

 

 

fixed glass panel assembly.

 

 

 

 

E. Thermopile or thermocouple.

Replace pilot if necessary.

 

 

 

 

F. Improper vent cap installation.

Check for proper installation and freedom from debris

 

 

or blockage.

 

 

 

6. Glass soots.

A. Flame impingement.

Adjust the log set so that the flame does not exces-

 

 

sively impinge on it. Refer to log instructions.

 

 

 

 

B. Improper air shutter setting.

Refer to manual for shutter set points. Ensure that set

 

 

point is correct for appliance/gas type. If unit has ad-

 

 

justable shutter, it may be necessary to increase shut-

 

 

ter opening.

 

 

 

 

C. Debris around air shutter.

Inspect the opening at the base of the burner. NO MA-

 

 

TERIAL SHOULD BE PLACED IN THIS OPENING.

 

 

 

7. Flame burns blue

A. Insufficient oxygen being supplied.

Ensure that the vent cap is installed properly and free

and lifts off burner.

 

of debris. Ensure that the vent system joints are tight

 

 

and have no leaks.

 

 

Ensure that no debris has been placed at the base of,

 

 

or in the area of the air holes in the center of the base

 

 

pan beneath the burner.

 

 

Ensure that the glass is tightened properly on the unit,

 

 

particularly on top corners.

 

 

 

68

Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI2164-900 Rev. T • 9/12

Image 68
Contents Hot glass will cause burns What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsLimited Lifetime Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyLimited Lifetime Warranty Warranty ConditionsTempered Glass Specifications BTU SpecificationsHigh Altitude Installations Listing and Code ApprovalsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Requirements for the Commonwealth of Massachusetts Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceIPI Battery Tray/Battery Installation Module ResetNine Hour Safety Shutdown Feature Control Module OperationLighting Instructions IPI Final inspection byWhat to do if YOU Smell GAS GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotAfter Fireplace is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsRefractory, Grate and Valve Assembly Removal Base RefractoryBurner Identification/Verification Notch LocationGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardFraming and Clearances Selecting Appliance Location6000 8000Constructing the Appliance Chase Clearances6000 8000Combustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications = 9 inches U.S.AVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowVent pipe, if desired 6000C-IPI 8000C-IPI V1 Minimum H1 MaximumTop Vent Horizontal Termination Two Elbows Three Elbows6000C-IPI V1 Minimum H1 + H2 Maximum 8000C-IPI V1 Minimum H1 + H2 MaximumBreak Top Vent Vertical Termination Maximum + V 2 MinTop Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumPage H1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H1 + H2 Maximum Minimum + H Maximum Rear Vent Vertical Termination One ElbowV1 Minimum H1 Maximum Rear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3 Maximum 10 ftPrior to installing the gas appliance Coaxial to Colinear VentingClearances to Combustibles Termination Cap Flue DamperRear Vent Connecting the DV-46DVA-GCL Adapter to Appliance Top VentConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPInstall Attic Insulation Shield Installing the Optional Heat-ZoneGas KitFlat Ceiling Installation Vaulted Ceiling InstallationAppliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outHeader Installing the Non-combustible BoardSecuring and Leveling the Appliance Installing Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Roof Pitch Min. Ft Install Metal Roof FlashingAssemble and Install Storm Collar Heat Shield Requirements for Horizontal Termination Install Vertical Termination CapInstall Decorative Wall Components SLP only Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements IntelliFire Plus Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsTo Junction Electrical Service and Repair Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialDoor FIT Finish Material See Thickness DoorsFinishing Material Inch Thick or Less Models Finishing Material Thickness 1-4 inches maximumFinishing Material Thickness 0-4 inches maximum Removal of Finishing Strips Finishing Strips RemovedElevated Hearth Systems Appliance Setup Bottom view Logs # 2 Install the Log Assembly Log Assembly LOGS-6C6000C, 6000C-IPI LOG Contacts Grate Tines Install the Log Assembly Log Assembly LOGS-8C 8000C-IPILP, 8000CBV-IPIHorizontal Grate BAR Install Trim and/or Surround Air Shutter SettingAir Shutter Settings 6000 8000Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemLocation Inches Millimeters Appliance Dimension DiagramReference Materials GAS Line Access R Left Side TOP View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP Horizontal Termination CapRF6M RF12M BEK DVP-BEK2DVP-TRAPFL COOL-ADDMDVP-TVHW DVP-FBHTOptional Wire Harness Power Vent InlinePVI-SLP SLP-LPCDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP LINK-DV30BDV-46DVA-GCL DVP-2SL AdapterSLP45 SLP90SLP Pipe DVP-SLP24SLP-WT-BK SLP-TRAPDVP-2SL SLP-CCS-BK SLK-SNKDSLP-DCF-BK SLP-TVHWService Parts At DepotGas Fireplace DV Beginning Manufacturing Date Aug8000C, 8000C-IPI 6000C-IPI 8000C-IPI8000C Stocked6000C Standing Pilot Conversion Kits IPI Conversion KitsContact Information