Heat & Glo LifeStyle 6000C manual Vent Diagrams Top Vent Horizontal Termination, One Elbow

Page 28

E. Vent Diagrams

 

 

 

 

 

 

 

Top Vent - Horizontal Termination

 

 

 

WARNING

 

 

 

 

 

 

Note: The 6000/8000 series fireplaces can adapt to SLP series

 

Fire Risk.

Explosion Risk.

vent pipe, if desired.

 

 

 

Do NOT pack insulation or other combustibles

When venting off the top of the unit, use a DVP-2SL

adapter and a

 

between ceiling firestops.

minimum 48 inch vertical section of SLP series vent pipe.

 

• ALWAYS maintain specified clearances around

A DVP-SLP24 adapter may also be used with a 24 inch vertical

 

venting and firestop systems.

section of SLP series vent pipe.

 

 

 

• Install wall shield and ceiling firestops as speci-

After the 48 inch vertical section, the venting table rules must be

 

fied.

 

 

followed. The first 48 inch vertical section is NOT counted as part

 

Failure to keep insulation or other material away

of the vertical components in the table. It is still counted as part of

 

from vent pipe may cause fire.

the overall maximum run. All venting table rules for the vent run

 

 

 

 

must still be followed.

 

 

 

 

 

WARNING

 

 

 

 

 

 

Example: DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal

 

Fire Risk.

 

 

SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal

 

• When using DVP-HRC-SS and DVP-HRC-ZC-

 

 

 

 

 

SS termination caps on top vented fireplaces, a

 

 

 

 

 

6 inch minimum vertical vent section is required

Top Vent - Horizontal Termination

 

 

before installing first elbow.

 

 

 

 

 

One Elbow

6000C-IPI

 

 

8000C-IPI

 

 

 

 

 

V1 Minimum

H1 Maximum

V1 Minimum

H1 Maximum

Elbow only

2 ft

610 mm

Elbow Only

2 ft.

610 mm

6 in.

152 mm

4 ft.

1.2 m

1 ft.

305 mm

3 ft.

914 mm

1 ft.

305 mm

6 ft.

1.8 m

2 ft.

610 mm

6 ft.

1.8 m

1-1/2 ft.

457 mm

10 ft.

3.0 m

3 ft.

914 mm

11 ft.

3.4 m

2 ft.

610 m

15 ft.

4.6 m

4 ft.

1.2 m

20 ft.

6.1 m

2-1/2 ft.

762 mm

20 ft.

6.1 m

V1

+ H1 = 40 ft. (12.2 m) Maximum

3 ft.

914 mm

25 ft.

7.6 m

 

H1 = 20 ft. (6.1 m) Maximum

V1

+ H1 = 40 ft. (12.2 m) Maximum

 

 

 

 

 

H1 = 25 ft. (7.6 m) Maximum

 

Note: For corner installations: A 6 inch (152

 

 

 

 

 

 

 

 

 

 

mm) section of straight pipe may need to

 

 

 

 

 

be attached to the appliance before a 90º

 

 

 

 

 

elbow, to allow the vent pipe to clear the top

 

 

 

 

 

standoffs.

 

H1

V1

Figure 7.3

28

Heat & Glo • 6000C, 6000C-IPI, 8000C, 8000C-IPI2164-900 Rev. T • 9/12

Image 28
Contents HOT Surfaces What to do if you smell gasHot glass will cause burns Congratulations Homeowner Reference InformationTable of Contents User GuideAppliance Setup TroubleshootingFinishing Reference MaterialsLimited Lifetime Warranty Hearth & Home Technologies Inc Limited Lifetime WarrantyLimited Lifetime Warranty Warranty ConditionsTempered Glass Specifications BTU SpecificationsHigh Altitude Installations Listing and Code ApprovalsNon-Combustible Materials Specification Combustible Materials SpecificationElectrical Codes C22.1Requirements for the Commonwealth of Massachusetts Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesFan Kit optional Clear SpaceIPI Battery Tray/Battery Installation Module ResetNine Hour Safety Shutdown Feature Control Module OperationLighting Instructions IPI Final inspection byWhat to do if YOU Smell GAS GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotIssue Solutions Frequently Asked QuestionsAfter Fireplace is Lit Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Qualified Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsRefractory, Grate and Valve Assembly Removal Base RefractoryBurner Identification/Verification Notch LocationGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Any such action may cause a fire hazardFraming and Clearances Selecting Appliance Location6000 8000Constructing the Appliance Chase Clearances6000 8000Combustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Termination Locations Vent Termination Minimum ClearancesCovered Alcove Applications = 9 inches U.S.AVent Information and Diagrams Approved PipeVent Table Key Use of ElbowsVent Diagrams Top Vent Horizontal Termination One ElbowVent pipe, if desired 6000C-IPI 8000C-IPI V1 Minimum H1 MaximumTop Vent Horizontal Termination Two Elbows Three Elbows6000C-IPI V1 Minimum H1 + H2 Maximum 8000C-IPI V1 Minimum H1 + H2 MaximumBreak Top Vent Vertical Termination Maximum + V 2 MinTop Vent Vertical Termination Three Elbows H1 + H2 V1 + V2 Minimum H1 + H2 MaximumPage H1 Maximum V1 Minimum H1 + H2 Maximum Rear Vent Horizontal Termination Two ElbowsH1 Maximum V1 Minimum H2+ H3 H1+ H2+ H3 Max V1 Minimum H1 Maximum Rear Vent Vertical Termination One ElbowMinimum + H Maximum Rear Vent Vertical Termination Three Elbows V1 Minimum H1 + H2 + H3 Maximum 10 ftPrior to installing the gas appliance Coaxial to Colinear VentingClearances to Combustibles Termination Cap Flue DamperConnecting the LINK-DV30B to the DV-46DVA-GCL adapter Connecting the DV-46DVA-GCL Adapter to Appliance Top VentRear Vent Vent Clearances and Framing Pipe Clearances to CombustiblesWall Penetration Framing Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVP SLPInstall Attic Insulation Shield Installing the Optional Heat-ZoneGas KitFlat Ceiling Installation Vaulted Ceiling InstallationAppliance Preparation Top VentRear Vent Cut the metal retaining band and fold the sides outSecuring and Leveling the Appliance Installing the Non-combustible BoardHeader Installing Vent Pipe DVP and SLP Pipe Attach Vent to the Firebox AssemblyAssemble Vent Sections DVP Pipe Only Assemble Pipe SectionsAssemble Vent Sections SLP Pipe Only Assemble Slip SectionsSecure the Vent Sections Disassemble Vent SectionsInstall Decorative Ceiling Components SLP only Assemble and Install Storm Collar Install Metal Roof FlashingRoof Pitch Min. Ft Install Decorative Wall Components SLP only Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Install Horizontal Termination Cap DVP and SLP Pipe DVP-HPC1 DVP-HPC2Gas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements IntelliFire Plus Ignition System WiringStanding Pilot Ignition System Wiring Optional Accessories RequirementsTo Junction Electrical Service and Repair Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialFinishing Material Inch Thick or Less DoorsDoor FIT Finish Material See Thickness Finishing Material Thickness 0-4 inches maximum Finishing Material Thickness 1-4 inches maximumModels Removal of Finishing Strips Finishing Strips RemovedElevated Hearth Systems Appliance Setup 6000C, 6000C-IPI Install the Log Assembly Log Assembly LOGS-6CBottom view Logs # 2 LOG Contacts Grate Tines Install the Log Assembly Log Assembly LOGS-8C 8000C-IPILP, 8000CBV-IPIHorizontal Grate BAR Install Trim and/or Surround Air Shutter SettingAir Shutter Settings 6000 8000Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionShorts in the wiring IntelliFire Plus Ignition SystemReference Materials Appliance Dimension DiagramLocation Inches Millimeters GAS Line Access R Left Side TOP View Front View Right View Vent Components Diagrams DVP-AS2DVP-TRAP Horizontal Termination CapRF6M RF12M BEK DVP-BEK2DVP-TRAPFL COOL-ADDMDVP-TVHW DVP-FBHTOptional Wire Harness Power Vent InlinePVI-SLP SLP-LPCDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP LINK-DV30BDV-46DVA-GCL DVP-2SL AdapterSLP45 SLP90SLP Pipe DVP-SLP24DVP-2SL SLP-TRAPSLP-WT-BK SLP-CCS-BK SLK-SNKDSLP-DCF-BK SLP-TVHWService Parts At DepotGas Fireplace DV Beginning Manufacturing Date Aug8000C, 8000C-IPI 6000C-IPI 8000C-IPI6000C Stocked8000C Standing Pilot Conversion Kits IPI Conversion KitsContact Information