Heat & Glo LifeStyle 6000 GDVFL, 6000 XLS manual Step Gas Supply Line, Mm hook-up at the unit

Page 26

STANDING PILOT

DSI IGNITION

 

 

IGNITOR

3/8" (10 mm)

1/2" (13 mm)

3/16" (5 mm)

Figure 22. Gas Controls Systems

23

Step 6

The Gas

Supply Line

NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building codes.

NOTE: Before the first firing of the fireplace, the gas supply line should be purged of any trapped air.

NOTE: Consult local building codes to properly size the gas supply line leading to the 1/2 inch

(13 mm) hook-up at the unit.

This gas fireplace is designed to accept a 1/2 inch (13 mm) gas supply line.

To install the gas supply line:

A listed 1/2 inch (13 mm) manual shut-off valve and a listed flexible gas connector are connected to the 1/2 inch (13 mm) inlet of the control valve.

A 1/8 inch (3 mm) N.P.T. plugged tapping, accessible for test gauge connection, should be provided for in the gas supply line leading to the unit’s shut-off valve.

Locate the gas line access hole in the outer casing of the fireplace.

Open the fireplace lower grille, insert the gas supply line through the gas line hole, and connect it to the shut-off valve.

When attaching the pipe, support the control so that the lines are not bent or torn.

After the gas line installation is complete, use a soap solution to carefully check all gas connections for leaks.

WARNING

DO NOT USE AN OPEN FLAME TO

CHECK FOR GAS LEAKS.

Image 26
Contents Heat-N-Glo Fireplace Safety and Warning Information Table of Contents Replacement PartsApprovals and Codes Installation CodesHigh Altitude Installations CodesGetting Started Diagram of the6000 Series Locating Installing the FireplaceStep Fireplace26-1/4 Step Framing FireplaceModel Models Step Installing Vent System Vent System ApprovalsDV-90D Corner Installation Venting with One 90 Elbow Venting with Two 90 Elbows Venting with three 90 elbows Installing Vent Components Attach the First Vent Component to the Starting CollarsAdding Venting Components Install Support Brackets Continue Adding Vent ComponentsInstalling Support Brackets 4. Install Firestops 12 Hole and Vent Pipe 11 Hole and New Framing Members Vent Termination Attic FirestopRound and Trapezoid Termination Caps If Exterior Walls are Finished with Major U.S. Building Codes Minimum Height from Roof to Lowest Discharge Opening Standing Pilot Ignition System Step Positioning Leveling, Securing FireplaceStep Gas Control Systems Direct Spark Ignition DSI SystemStep Gas Supply Line Mm hook-up at the unitStep Gas Pressure Requirements Pressure Natural Gas PropaneOptional Accessories Step Wiring FireplaceFor Standing Pilot Ignition Wiring Remote Wall SwitchFor Direct Spark Ignition DSI Wiring Fan Wiring DiagramDirect Spark Ignition DSI Wiring Diagram Step FinishingHearth Extensions Step Installing Trim Logs, Ember MaterialInstalling the Trim Placing the Ember Material Positioning the LogsSave the log instructions with this manual Glass Assembly Double-check for faulty components Step Before Lighting Fireplace After InstallationReview safety warnings and cautions Double-check for gas leaksFireplace Maintenance Maintaining and Servicing Your FireplaceBurner Flame Patterns Replacement Parts Accessories Standing Pilot OnlyDSI Ignition Only 6000XLS 20 X Both Standing Pilot and DSI Ignition20 X Models Mesh