Heat & Glo LifeStyle 6000 XLS Fireplace Maintenance, Maintaining and Servicing Your Fireplace

Page 35

Fireplace Maintenance

Although the frequency of your fireplace servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

4

IMPORTANT

TURN OFF THE GAS BEFORE SERVICING

 

 

YOUR FIREPLACE.

 

 

 

 

 

 

Type of

 

 

 

 

 

Fireplace

 

 

 

Fireplace Maintenance Task To

Maintenance

 

Frequency

By

Be Completed

 

 

 

 

 

Replacing

Once annually,

Qualified

Brush away loose ember material near

Old Ember

during the

Service

the burner. Replace old ember

Material

annual check-up

Technician

material with new dime-size and -shape

 

 

 

 

pieces of Golden Ember (GE-93) and

 

 

 

 

Glowing Ember (050-721). New ember

 

 

 

 

material should be placed alternately on

 

 

 

 

top of the burner—a layer of Golden

 

 

 

 

Ember, a layer of Glowing Ember,

 

 

 

 

and so on. Save the remaining ember

 

 

 

 

material and repeat this procedure at

 

 

 

 

your next servicing. For more

 

 

 

 

information, see Placing Ember

 

 

 

 

Material in the INSTALLERS GUIDE.

 

 

 

 

 

Cleaning

Once annually

Qualified

Brush or vacuum the control

Burner

 

 

Service

compartment, fireplace logs, and

& Controls

 

 

Technician

burner areas surrounding the logs.

 

 

 

 

 

Checking

Periodically

Qualified

Make a visual check of your fireplace’s

Flame

 

 

Service

flame patterns. Make sure the flames

Patterns,

 

 

Technician

are steady—not lifting or floating. See

Flame Height

 

 

 

the picture in Figure 31. The flame

 

 

 

 

s e n s o r (DSI) or thermopile/thermocouple

 

 

 

 

(standing pilot) tips should be covered

 

 

 

 

with flame. See the picture in Figure 32.

 

 

 

 

 

Checking

Before initial use

Qualified

Inspect the external vent cap on a

Vent System

and at least

Service

regular basis to ensure that no debris is

 

annually thereafter,

Technician/

interfering with the flow of air.

 

more frequently

Owner

 

 

 

if possible

 

 

 

 

 

 

 

 

 

Cleaning

As

necessary

Homeowner

Clean as necessary, particularly after

Glass Door

 

 

 

adding new ember (flame colorant)

 

 

 

 

material. Film deposits on the inside of

 

 

 

 

the glass door should be cleaned off

 

 

 

 

using a household glass cleaner.

 

 

 

 

NOTE: DO NOT handle or attempt to

 

 

 

 

clean the door when it is hot and

 

 

 

 

DO NOT use abrasive cleaners.

 

 

 

 

 

 

 

 

 

 

 

 

Maintaining and Servicing Your Fireplace

32

Image 35
Contents Heat-N-Glo Fireplace Safety and Warning Information Replacement Parts Table of ContentsCodes Installation CodesHigh Altitude Installations Approvals and CodesGetting Started Diagram of the6000 Series Fireplace Installing the FireplaceStep Locating26-1/4 Step Framing FireplaceModel Models Vent System Approvals Step Installing Vent SystemDV-90D Corner Installation Venting with One 90 Elbow Venting with Two 90 Elbows Venting with three 90 elbows Attach the First Vent Component to the Starting Collars Installing Vent ComponentsContinue Adding Vent Components Adding Venting Components Install Support BracketsInstalling Support Brackets 4. Install Firestops 12 Hole and Vent Pipe 11 Hole and New Framing Members Attic Firestop Vent TerminationRound and Trapezoid Termination Caps If Exterior Walls are Finished with Major U.S. Building Codes Minimum Height from Roof to Lowest Discharge Opening Direct Spark Ignition DSI System Step Positioning Leveling, Securing FireplaceStep Gas Control Systems Standing Pilot Ignition SystemMm hook-up at the unit Step Gas Supply LinePressure Natural Gas Propane Step Gas Pressure RequirementsRemote Wall Switch Step Wiring FireplaceFor Standing Pilot Ignition Wiring Optional AccessoriesFan Wiring Diagram For Direct Spark Ignition DSI WiringStep Finishing Direct Spark Ignition DSI Wiring DiagramHearth Extensions Step Installing Trim Logs, Ember MaterialInstalling the Trim Placing the Ember Material Positioning the LogsSave the log instructions with this manual Glass Assembly Double-check for gas leaks Step Before Lighting Fireplace After InstallationReview safety warnings and cautions Double-check for faulty componentsMaintaining and Servicing Your Fireplace Fireplace MaintenanceBurner Flame Patterns Standing Pilot Only Replacement Parts AccessoriesDSI Ignition Only 6000XLS 20 X Both Standing Pilot and DSI Ignition20 X Models Mesh