Heat & Glo LifeStyle 6000 XLS, 6000 GDVFL manual Step, Locating, Installing the Fireplace

Page 7

Step 1

The diagram below shows space and clearance

Locating the

requirements for locating a fireplace within a room.

Fireplace

 

Figure 2. Fireplace Dimensions, Locations, and

Space Requirements

Clearance Requirements

The top, back, and sides of the fireplace are defined by stand-offs.

Minimum Clearances from the Fireplace to

Combustible Materials

Glass

 

Back of

Sides of

Top of

 

Front

Floor

Fireplace

Fireplace

Fireplace

Ceiling

 

 

 

 

 

 

36 inches

0

1/2 inch

1/2 inch

3-1/2 inches

31 inches

(914 mm)

 

(13 mm)

(13 mm)

(89 mm)

(787 mm)

 

 

 

 

 

 

The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm).

For 6000 Series Models, the back of the fireplace may be recessed 21-1/2 inches (546 mm) into combustible construction.

3

Installing the Fireplace

4

Image 7
Contents Heat-N-Glo Fireplace Safety and Warning Information Replacement Parts Table of ContentsCodes Installation CodesHigh Altitude Installations Approvals and CodesGetting Started Diagram of the6000 Series Fireplace Installing the FireplaceStep LocatingModel Models Step Framing Fireplace26-1/4 Vent System Approvals Step Installing Vent SystemDV-90D Corner Installation Venting with One 90 Elbow Venting with Two 90 Elbows Venting with three 90 elbows Attach the First Vent Component to the Starting Collars Installing Vent ComponentsContinue Adding Vent Components Adding Venting Components Install Support BracketsInstalling Support Brackets 4. Install Firestops 12 Hole and Vent Pipe 11 Hole and New Framing Members Attic Firestop Vent TerminationRound and Trapezoid Termination Caps If Exterior Walls are Finished with Major U.S. Building Codes Minimum Height from Roof to Lowest Discharge Opening Direct Spark Ignition DSI System Step Positioning Leveling, Securing FireplaceStep Gas Control Systems Standing Pilot Ignition SystemMm hook-up at the unit Step Gas Supply LinePressure Natural Gas Propane Step Gas Pressure RequirementsRemote Wall Switch Step Wiring FireplaceFor Standing Pilot Ignition Wiring Optional AccessoriesFan Wiring Diagram For Direct Spark Ignition DSI WiringStep Finishing Direct Spark Ignition DSI Wiring DiagramInstalling the Trim Step Installing Trim Logs, Ember MaterialHearth Extensions Save the log instructions with this manual Positioning the LogsPlacing the Ember Material Glass Assembly Double-check for gas leaks Step Before Lighting Fireplace After InstallationReview safety warnings and cautions Double-check for faulty componentsMaintaining and Servicing Your Fireplace Fireplace MaintenanceBurner Flame Patterns Standing Pilot Only Replacement Parts AccessoriesDSI Ignition Only 20 X Both Standing Pilot and DSI Ignition6000XLS 20 X Models Mesh