Design Dynamics DVF-36S-N installation manual Gas Connection

Page 15
Natural - From
Gas Meter (5.5" W.C. to 10.5" W.C. Pressure) Propane/LP From External Regulator (11" W.C. to 14" W.C. Pressure)

Fireplace

Installation

Continued

For propane/LP connection only, the installer must supply an external regulator. The exter- nal regulator will reduce incoming gas pres- sure. You must reduce incoming gas pressure to between 11" and 14" of w.c. pressure. If you do not reduce incoming gas pressure, fireplace regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 20. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow proper gas volume to fireplace. If pipe is too small, undue loss of volume will occur.

Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from fireplace (see Figure 21).

IMPORTANT: Install main gas valve (equip- ment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting off the gas to the appliance.

Check your building codes for any special requirements for locating equipment shutoff valve to fireplaces.

Propane/LP

Supply TankExternal

Regulator

Vent

Pointing

Down

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged fireplace valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

We recommend that you install a sediment trap/drip leg in supply line as shown in Figure

21.Locate sediment trap/drip leg where it is within reach for cleaning. Install in piping sys- tem between fuel supply and fireplace. Locate sediment trap/drip leg where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace gas controls. If sedi- ment trap/drip leg is not installed or is installed wrong, fireplace may not run properly.

CSA Design-Certified Equipment Shutoff Valve with 1/8" NPT Tap*

Approved

Flexible

Gas Line

3" Minimum

Cap Pipe Tee

Joint Nipple

Sediment Trap/

Drip Leg

Figure 21 - Gas Connection

*The CSA design-certified equipment shutoff valve may be supplied with the appliance or you can purchase it from your retailer.

Figure 20 - External Regulator with Vent

Pointing Down (Propane/LP Only)

120441-01A

www.desatech.com

15

Image 15
Contents Natural Propane/LP Gas Models Gas ModelsStacked Brick/Standard Glass Safety Information Table of ContentsThis fireplace Natural and Propane/LP Gas NaturalProduct Features Product IdentificationLocal Codes Proper clearances must be maintained PreinstallationInstallation Location and space requirementsClearances ClearancesFraming and finishing For specific ventingBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting InstallationTwist-Lock Procedure The female Installation PlanningApply Mastic to All Four Sides Vent Cap Wood Screw See ,To All Four Sides Elbow Wall Firestop Horizontal High Wind Square TerminationMax max max Flat Ceiling Installation Vertical Termination Installation= 40 max Outside Air Flex InstallationHigh Altitude Installation Vertical VentingCheck GAS Type Fireplace InstallationParts list for venting kits and components Installing Gas Piping to Fireplace LocationGas Connection Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Connecting Fireplace to GAS SupplyChecking GAS Connections Psig 3.5 kPa will damage fireplace gas regulatorFireplace Pressure Testing Fireplace Gas ConnectionsInstalling Middle Door DVF-36SC/HC Models Only Installing Outer Door DVF-36SC/HC Models OnlyRemove screen and rod see , See , Follow these instructions in reverse to reinstallSpring Loaded Pin Pin Located on Middle DoorHook Located Outer Door Hinge On Inner Door Middle DoorMiddle Bottom Brick Right Bottom Brick Lava Rock, Ember Flakes Scrap Log InstallationSide Bricks Side Trim Screen Rod Left Bottom BrickRemote control Installation Model WRC Wall Switch InstallationLighting Instructions Wiring DiagramFor your safety Read before lighting OperationRemote Operation Pilot AssemblyInspecting Burners To Turn OFF GAS To ApplianceGlass Doors Cleaning MaintenanceService Hints Technical ServiceSpecifications Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingPoor ground to ignition 21 and/or check ground wire to ignition modulePilot will not stay lit To ignition module and/orConfiguration Tions,Glass soots Debris around burner air Illustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated parts breakdown Bottom Pan Weldment Illustrated parts breakdown 120168-01 Refractory Trim, RH 120168-02 Refractory Trim, LH 120441-01A 120441-01A Direct vent Fireplace Warranty InformationKeep this Warranty Limited Warranty