Cleaning and

Maintenance

Continued

WARNING:Donotoperatefire- place with glass door unlatched, removed, cracked or broken.

pilot and burners

Remove material before cleaning burners and replace when cleaning is complete.

Burner and controls should be cleaned with compressed air to remove dust, dirt or lint.

Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt or lint.

logs

Use a vacuum cleaner to remove any carbon buildup on logs.

Replace material periodically as needed. See Replacement Parts.

venting system

Conduct annual inspection of the venting system following these guidelines:

1.Check areas of venting system that are exposed to the weather for corrosion (rust spots or streaks and, in extreme cases, holes). Have these items replaced im- mediately by a qualified service person.

2.Remove the vent cap and shine a flash- light into the vent. Remove any foreign material.

3.Check for evidence of excessive con- densation. Continuous condensation can cause corrosion of caps, pipes and fittings and can be caused by having excessive lateral runs, too many elbows or exterior portions of the system being exposed to cold weather.

4.Inspect joints to verify that no pipe section or fitting has been disturbed and loos- ened. Check mechanical supports such as wall straps for rigidity.

Technical Service

You may have further questions about instal- lation, operation or troubleshooting. If so, contact DESA’s Customer Service Depart- ment at 1-866-672-6040. When calling, please have your model and serial numbers of your heater ready.

You can also visit DESA’s technical service web site at www.desatech.com.

Specifications

DVF-36S-N, DVF-36H-N, DVF-36SC-N, DVF-36HC-N

Rating: 66,000 Btu/hr

Gas Type: Natural Gas Only

Ignition: Electronic

Manifold Pressure: 3.5" w.c.

Minimum Inlet Supply Pressure: 7.0" w.c.

DVF-36S-P, DVF-36H_P, DVF-36SC-P, DVF-36SH-P

Rating: 62,000 Btu/hr

Gas Type: Propane/LP Gas Only

Ignition: Electronic

Manifold Pressure: 10.0" w.c.

Minimum Inlet Supply Pressure: 11.0" w.c.

Replacement Parts

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

Parts Under Warranty

Contact authorized retailers of this product. If they can not supply original replacement part(s), call DESA’s Customer Service Depart- ment at 1-866-672-6040.

When calling DESA, have ready

your name

your address

model and serial numbers of your fire- place

how fireplace was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the part to the factory.

Parts Not Under Warranty

Contact authorized retailers of this product.

If they can not supply original replacement

part(s), call DESA at 1-866-672-6040 for

referral information.

When calling DESA, have ready

model number of your fireplace

the replacement part number

Service Hints

When Gas Pressure Is Too Low

pilot will not stay lit

burners will have delayed ignition

fireplace will not produce specified heat

propane/LP gas supply might be low (pro- pane/LP units only)

You may feel your gas pressure is too low. If so, contact your local gas supplier.

24

www.desatech.com

120441-01A

Image 24
Contents Natural Propane/LP Gas Models Gas ModelsStacked Brick/Standard Glass Table of Contents Safety InformationNatural and Propane/LP Gas Natural This fireplaceProduct Features Product IdentificationLocal Codes Preinstallation InstallationLocation and space requirements Proper clearances must be maintainedClearances Framing and finishingFor specific venting ClearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Installation PrecautionsInstallation Planning Twist-Lock Procedure The femaleApply Mastic to All Four Sides Vent Cap Wood Screw See ,To All Four Sides Elbow Wall Firestop Horizontal High Wind Square TerminationMax max max Vertical Termination Installation Flat Ceiling InstallationOutside Air Flex Installation High Altitude InstallationVertical Venting = 40 maxFireplace Installation Parts list for venting kits and componentsInstalling Gas Piping to Fireplace Location Check GAS TypeGas Connection Connecting Fireplace to GAS Supply Checking GAS ConnectionsPsig 3.5 kPa will damage fireplace gas regulator Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaPressure Testing Fireplace Gas Connections Installing Middle Door DVF-36SC/HC Models OnlyInstalling Outer Door DVF-36SC/HC Models Only FireplaceSee , Follow these instructions in reverse to reinstall Spring Loaded Pin Pin Located on Middle DoorHook LocatedOuter Door Hinge On Inner Door Middle Door Remove screen and rod see ,Lava Rock, Ember Flakes Scrap Log Installation Side Bricks Side Trim Screen Rod LeftBottom Brick Middle Bottom Brick Right Bottom BrickWall Switch Installation Remote control Installation Model WRCWiring Diagram For your safety Read before lightingOperation Lighting InstructionsPilot Assembly Inspecting BurnersTo Turn OFF GAS To Appliance Remote OperationCleaning Maintenance Glass DoorsTechnical Service SpecificationsReplacement Parts Service HintsTroubleshooting Observed Problem Possible Cause Remedy21 and/or check ground wire to ignition module Pilot will not stay litTo ignition module and/or Poor ground to ignitionConfiguration Tions,Glass soots Debris around burner air Illustrated Parts Breakdown Parts List Not a field replaceable partIllustrated parts breakdown Bottom Pan Weldment Illustrated parts breakdown 120168-01 Refractory Trim, RH 120168-02 Refractory Trim, LH 120441-01A 120441-01A Warranty Information Keep this WarrantyLimited Warranty Direct vent Fireplace