PreInstallation
Continued
Clearances
Minimum clearances to combustibles for the fireplace are as follows:
| *Back and sides | 0" | 
| Perpendicular walls | 6" | 
| Floor | 0" | 
| Ceiling to louver opening | 42" | 
| Front | 36" | 
| Top of Standoffs | 0" | 
| Vent | (See venting instructions | 
| 
 | for specific venting | 
| 
 | clearances.) | 
Combustible material with a maximum thick- ness of 5/8" may be flush with the top front of fireplace.
43 1/4"
33"
56 3/4"
28"
*For back and sides of fireplace, do not pack with insulation or other materials. 0" clear- ance to combustible materials are for framing purpose only.
NOTICE: This fireplace is intend- ed for use as supplemental heat. Use this fireplace along with your primary heating system. Do not install this fireplace as your primary heat source. If you have a central heating system, you may run system’s circulat- ing blower while using fireplace. This will help circulate the heat throughout the house.
framing and finishing
Figure 4 shows typical framing of this fireplace. Figure 5 shows framing for corner installation. All minimum clearances must be met.
If you are using a separate combustible man- tel piece, refer to Figure 6 for proper instal- lation height. You can install noncombustible mantels at any height above the fireplace.
Note: Noncombustible mantels may discolor!
Figure 4 - Framing Clearances with
Outside Air Flex Duct
| 
 | 
 | 
 | 
 | 
 | 58 1/4" | 
| 
 | 41 3/8" | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | 199/16" | 
 | 
 | 
| 
 | 
 | 
 | 43" | 
 | 
 | 
| 
 | 
 | 
 | 43 1/4" | 
 | Nailing | 
| 
 | 
 | 
 | 82 1/8" | 
 | Tabs | 
| 
 | 
 | 
 | 
 | 
 | |
| 
 | Figure 5 - Framing Clearances for | ||||
| 
 | 
 | Corner Installation | |||
| 
 | 
 | 
 | 
 | 1 | 
 | 
| 
 | 
 | 
 | 
 | 2 | 
 | 
| 
 | A | 
 | 
 | 3 | 
 | 
| 
 | 
 | 
 | 4 | Wall | |
| 
 | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | |
| 
 | B | 
 | 
 | 5 | 
 | 
| 
 | 
 | C | 
 | 6 | 
 | 
| 
 | 
 | 
 | D E | 
 | |
| 
 | 
 | 
 | 7 | 
 | |
| 
 | 
 | 
 | F | G | 
 | 
| 
 | 
 | 
 | Mantel | 
 | 
 | 
| 
 | Mantel | 
 | from Top of | 
 | |
| Ref. Depth Ref. | Opening | 
 | |||
| 1 | 14" | A | 16" | 
 | 
 | 
| 2 | 12" | B | 14" | 
 | 
 | 
| 3 | 10" | C | 12" | 
 | 
 | 
| 4 | 8" | D | 10" | 
 | 
 | 
| 5 | 6" | E | 8" | 
 | 
 | 
| 6 | 4" | F | 6" | 
 | 
 | 
| 7 | 2" | G | 4" | 
 | 
 | 
Figure 6 - Clearances for Combustible
Mantels
www.desatech.com120441-01A