PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual.

KEY NO.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

PART NO.

DESCRIPTION

 

120150-01

Outer Glass Assembly

 

120155-01

Middle Glass Assembly

 

118003-01

Glass Door Assembly

 

118003-02

Glass Door Assembly

**

Face Weldment

17327

Latch Spring

**

Left Side Surround

**

Right Side Surround

**

Fireplace Bottom

**

Rear Fireplace Surround

**

Firebox Surround

**

Firebox Bottom

**

Firebox Top Assembly

120244-01

Air Plenum

117479-01

Air Exchange

**

Top Insulation

120261-01

Fireplace Top

23490SA

Fireplace Top Spacer

120243-01

8" Outer Pipe

111554-05

5" Inner Connector

106702-01

5" Gasket

120431-01

Burner Base Gasket

117997-01

Glass Door Retainer

120142-01

Firebox Leg

117891-01

Fireplace Handle

21171

Gas Conduit Cover

24460

Gas Conduit Assembly

120152-02

Frame Leaf Hinge

120454-01

Ignition Valve Assembly

120454-02

Ignition Valve Assembly

 

120154-01

Door Latch Bracket

 

120687-01

Plenum Bracket

120461-01

Screen

120411-01

Log Burner Assembly, NG (See page 30)

120411-02

Log Burner Assembly, LP (See page 30)

 

120895-01

Relief Plate

120902-02

Gasket

120899-01

Thumb Screw

120898-01

Spring

11418

Push Nut

120462-01

Screen Rod

121126-01

Screen Rod Bracket

121063-01

Aniron

110037-01

Electrical Duct ASM

11192

Hex Spacer Screw

121127-01

Access Cover Plate

 

N

 

P

-

-

36S

 

36S

 

-

 

-

 

DVF

 

DVF

 

 

 

 

 

 

N

-

36H

 

-

 

DVF

 

 

P

 

-

 

36H

 

-

-

 

DVF

DVF

 

 

 

 

 

 

N

 

-

 

36SC

-

DVF

 

 

 

P

 

-

 

36SC

-

DVF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

36HC

-

-

 

DVF

 

 

 

36HC

P -

QTY.

1

1

1

1

1

6

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

1

1

4

4

1

1

3

1

1

2

1

2

1

1

2

2

6

6

2

1

1

2

1

4

1

**Not a field replaceable part.

120441-01A

www.desatech.com

29

Image 29
Contents Stacked Brick/Standard Glass NaturalPropane/LP Gas Models Gas Models Safety Information Table of ContentsThis fireplace Natural and Propane/LP Gas NaturalLocal Codes Product FeaturesProduct Identification Installation PreinstallationLocation and space requirements Proper clearances must be maintainedFraming and finishing ClearancesFor specific venting ClearancesBalcony with Perpendicular Side Wall Location of Termination CapInstallation Precautions Venting InstallationTwist-Lock Procedure The female Installation PlanningTo All Four Sides Apply Mastic to All Four Sides Vent Cap Wood ScrewSee , Max max max Elbow Wall FirestopHorizontal High Wind Square Termination Flat Ceiling Installation Vertical Termination InstallationHigh Altitude Installation Outside Air Flex InstallationVertical Venting = 40 maxParts list for venting kits and components Fireplace InstallationInstalling Gas Piping to Fireplace Location Check GAS TypeGas Connection Checking GAS Connections Connecting Fireplace to GAS SupplyPsig 3.5 kPa will damage fireplace gas regulator Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Middle Door DVF-36SC/HC Models Only Pressure Testing Fireplace Gas ConnectionsInstalling Outer Door DVF-36SC/HC Models Only FireplaceSpring Loaded Pin Pin Located on Middle DoorHook Located See , Follow these instructions in reverse to reinstallOuter Door Hinge On Inner Door Middle Door Remove screen and rod see ,Side Bricks Side Trim Screen Rod Left Lava Rock, Ember Flakes Scrap Log InstallationBottom Brick Middle Bottom Brick Right Bottom BrickRemote control Installation Model WRC Wall Switch InstallationFor your safety Read before lighting Wiring DiagramOperation Lighting InstructionsInspecting Burners Pilot AssemblyTo Turn OFF GAS To Appliance Remote OperationGlass Doors Cleaning MaintenanceSpecifications Technical ServiceReplacement Parts Service HintsObserved Problem Possible Cause Remedy TroubleshootingPilot will not stay lit 21 and/or check ground wire to ignition moduleTo ignition module and/or Poor ground to ignitionGlass soots Debris around burner air ConfigurationTions, Illustrated Parts Breakdown Not a field replaceable part Parts ListIllustrated parts breakdown Bottom Pan Weldment Illustrated parts breakdown 120168-01 Refractory Trim, RH 120168-02 Refractory Trim, LH 120441-01A 120441-01A Keep this Warranty Warranty InformationLimited Warranty Direct vent Fireplace