Design Dynamics DVF-36S-N Spring Loaded Pin Pin Located on Middle DoorHook Located

Page 18

Fireplace Installation

Spring Loaded Pin

Continued

Pin Located on

Middle DoorHook Located

UNLOCK

LOCK

Outer

Door

Hinge

on Inner Door

Middle Door

Inner Door

Figure 26 - Removing/Installing Middle Door

Removing and Installing Inner Door Inner door is factory installed.

1.Open outer door. Secure door in open position to avoid accidental breakage.

2.Remove middle door by lifting from hinges (see Figure 26). Set aside to avoid scratches or damage.

3.Remove screws from two side trims (see

Figure 27, page 19).

4.Remove side bricks from top to bottom by prying out of housings(see Figure 27, page 19).

5.Remove bottom bricks, starting with middle section (see Figure 27, page 19).

6.Remove screen and rod (see Figure 27, page 19).

7.While holding inner door, release 6 latches, 3 top and 3 bottom (see Figure 28, page

19).

8.Slowly tilt open glass at a 30° angle and lift up to release glass from bottom retainer

(see Figure 28, page 19).

9.Follow these instructions in reverse to reinstall.

18

www.desatech.com

120441-01A

Image 18
Contents Natural Propane/LP Gas Models Gas ModelsStacked Brick/Standard Glass Table of Contents Safety InformationNatural and Propane/LP Gas Natural This fireplaceProduct Features Product IdentificationLocal Codes Location and space requirements PreinstallationInstallation Proper clearances must be maintainedFor specific venting ClearancesFraming and finishing ClearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Installation PrecautionsInstallation Planning Twist-Lock Procedure The femaleApply Mastic to All Four Sides Vent Cap Wood Screw See ,To All Four Sides Elbow Wall Firestop Horizontal High Wind Square TerminationMax max max Vertical Termination Installation Flat Ceiling InstallationVertical Venting Outside Air Flex InstallationHigh Altitude Installation = 40 maxInstalling Gas Piping to Fireplace Location Fireplace InstallationParts list for venting kits and components Check GAS TypeGas Connection Psig 3.5 kPa will damage fireplace gas regulator Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Outer Door DVF-36SC/HC Models Only Pressure Testing Fireplace Gas ConnectionsInstalling Middle Door DVF-36SC/HC Models Only FireplaceOuter Door Hinge On Inner Door Middle Door See , Follow these instructions in reverse to reinstallSpring Loaded Pin Pin Located on Middle DoorHook Located Remove screen and rod see ,Bottom Brick Lava Rock, Ember Flakes Scrap Log InstallationSide Bricks Side Trim Screen Rod Left Middle Bottom Brick Right Bottom BrickWall Switch Installation Remote control Installation Model WRCOperation Wiring DiagramFor your safety Read before lighting Lighting InstructionsTo Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Remote OperationCleaning Maintenance Glass DoorsReplacement Parts Technical ServiceSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyTo ignition module and/or 21 and/or check ground wire to ignition modulePilot will not stay lit Poor ground to ignitionConfiguration Tions,Glass soots Debris around burner air Illustrated Parts Breakdown Parts List Not a field replaceable partIllustrated parts breakdown Bottom Pan Weldment Illustrated parts breakdown 120168-01 Refractory Trim, RH 120168-02 Refractory Trim, LH 120441-01A 120441-01A Limited Warranty Warranty InformationKeep this Warranty Direct vent Fireplace