Design Dynamics DVF-36S-N Fireplace Installation, Parts list for venting kits and components

Page 14

Venting Installation

Continued

parts list for venting kits and components

DESA (5"/8") Pipe & Vent Kits

Number

Description

P58-6

6" Section Double Wall Pipe,

 

Galvanized

P58-12

12" Section Double Wall Pipe,

 

Galvanized

P58-24

24" Section Double Wall Pipe,

 

Galvanized

P58-36

36" Section Double Wall Pipe,

 

Galvanized

P58-48

48" Section Double Wall Pipe,

 

Galvanized

PA58-712

Adjustable 7"-12" Section Double

 

Wall Pipe, Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

HTS-58

Horizontal Square Termination,

 

Galvanized

VT-58

Vertical Round Termination,

 

Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch,

 

Galvanized

RF-58-12

Roof Flashing - 6/12 to 12/12 Pitch,

 

Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff,

 

Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

 

For use with HTS-58

RF-58

Flat Roof Flashing

AK6-37

37" Outside Air Flex Vent Kit

AK6-75

75" Outside Air Flex Vent Kit

Fireplace

Installation

CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type.

Installing Gas Piping to Fireplace Location

WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes.

CAUTION: For propane/LP units, never connect fireplace directly to the propane/LP sup- ply. This heater requires an ex- ternal regulator (not supplied). Install the external regulator between the fireplace and pro- pane/LP supply.

WARNING: For natural gas, never connect fireplace to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

Installation Items Needed

Before installing fireplace, make sure you

have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

test gauge connection *

sediment trap

tee joint

pipe wrench

approved flexible gas line with gas connec- tor (if allowed by local codes)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable al- ternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your retailer.

14

www.desatech.com

120441-01A

Image 14
Contents Stacked Brick/Standard Glass NaturalPropane/LP Gas Models Gas Models Table of Contents Safety InformationNatural and Propane/LP Gas Natural This fireplaceLocal Codes Product FeaturesProduct Identification Location and space requirements PreinstallationInstallation Proper clearances must be maintainedFor specific venting ClearancesFraming and finishing ClearancesLocation of Termination Cap Balcony with Perpendicular Side WallVenting Installation Installation PrecautionsInstallation Planning Twist-Lock Procedure The femaleTo All Four Sides Apply Mastic to All Four Sides Vent Cap Wood ScrewSee , Max max max Elbow Wall FirestopHorizontal High Wind Square Termination Vertical Termination Installation Flat Ceiling InstallationVertical Venting Outside Air Flex InstallationHigh Altitude Installation = 40 maxInstalling Gas Piping to Fireplace Location Fireplace InstallationParts list for venting kits and components Check GAS TypeGas Connection Psig 3.5 kPa will damage fireplace gas regulator Connecting Fireplace to GAS SupplyChecking GAS Connections Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaInstalling Outer Door DVF-36SC/HC Models Only Pressure Testing Fireplace Gas ConnectionsInstalling Middle Door DVF-36SC/HC Models Only FireplaceOuter Door Hinge On Inner Door Middle Door See , Follow these instructions in reverse to reinstallSpring Loaded Pin Pin Located on Middle DoorHook Located Remove screen and rod see ,Bottom Brick Lava Rock, Ember Flakes Scrap Log InstallationSide Bricks Side Trim Screen Rod Left Middle Bottom Brick Right Bottom BrickWall Switch Installation Remote control Installation Model WRCOperation Wiring DiagramFor your safety Read before lighting Lighting InstructionsTo Turn OFF GAS To Appliance Pilot AssemblyInspecting Burners Remote OperationCleaning Maintenance Glass DoorsReplacement Parts Technical ServiceSpecifications Service HintsTroubleshooting Observed Problem Possible Cause RemedyTo ignition module and/or 21 and/or check ground wire to ignition modulePilot will not stay lit Poor ground to ignitionGlass soots Debris around burner air ConfigurationTions, Illustrated Parts Breakdown Parts List Not a field replaceable partIllustrated parts breakdown Bottom Pan Weldment Illustrated parts breakdown 120168-01 Refractory Trim, RH 120168-02 Refractory Trim, LH 120441-01A 120441-01A Limited Warranty Warranty InformationKeep this Warranty Direct vent Fireplace