Vermont Casting DVT38S2 installation instructions General Venting Information Termination Location

Page 10

Chateau™ Decorative Gas Appliance

General Venting Information - Termination Location

INSIDE

CORNER DETAIL

D

E V L

C

G

V

A

B

H N N

B

CFM145a

V�����

������

F

V

Operable

 

B

V

 

B

V

 

Operable

Fixed

 

 

 

Closed

 

 

 

 

 

 

 

V J

B

M

B

X

V K X

 

A

 

I

 

 

 

 

CFM145 V VENT TERMINATION X AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED

 

 

 

Canadian Installations1

US Installations2

 

 

A =

Clearance above grade, veranda, porch,

12” (30cm)

12” (30cm)

 

 

deck, or balcony

 

 

 

 

B = Clearance to window or door that may be

6” (15cm) for appliances

6” (15cm) for appliances

 

 

opened

< 10,000Btuh (3kW), 12” (30cm)

< 10,000 Btuh (3kW), 9”

 

 

 

for appliances > 10,000 Btuh (3kW) and

(23cm) for appliances > 10,000

 

 

 

< 100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

C* =Clearance to permanently closed window

12” (305mm) recommended to

12” (305mm) recommended to

 

 

 

prevent window condensation

prevent window condensation

 

D* =Vertical clearance to ventilated soffit located

 

 

 

 

 

above the terminal within a horizontal

18” (458mm)

18” (458mm)

 

 

distance of 2’ (610mm) from the center

 

 

 

 

 

line of the terminal

 

 

 

 

E = Clearance to unventilated soffit

12” (305mm)*CAUTION: Clearances to soffit do not12”apply(305mm)to “vinyl soffits”.

 

F =

Clearance to outside corner

see next page

see next page

 

G = Clearance to inside corner (see next page)

see next page

see next page

 

H = Clearance to each inside of center line

3’ (91cm) within a height of 15’ (5m)

3’ (91cm) within a height of 15’

 

 

extended above meter/regulator assembly

above the meter/regulator assembly

(5m) above the meter/regulator

 

 

 

 

assy

 

I =

Clearance to service regulator vent outlet

3’ (91cm)

3’ (91cm)

 

J =

Clearance to nonmechanical air supply inlet

6” (15cm) for appliances < 10,000

6” (15cm) for appliances

 

 

to building or the combustion air inlet to any

Btuh (3kW), 12” (30cm) for

< 10,000 Btuh (3kW), 9”

 

 

other appliances

appliances > 10,000 Btuh (3kW) and <

(23cm) for appliances > 10,000

 

 

 

100,000 Btuh (30kW), 36” (91cm)

Btuh (3kW) and < 50,000 Btuh

 

 

 

for appliances > 100,000 Btuh (30kW)

(15kW), 12” (30cm) for

 

 

 

 

appliances > 50,000 Btuh (15kW)

 

K =

Clearance to a mechanical air supply inlet

6’ (1.83m)

3’ (91cm) above if within 10’

 

 

 

 

(3m) horizontally

 

L =

Clearance above paved sidewalk or paved

7’ (2.13m)†

7’ (2.13m)†

 

 

driveway located on public property

 

 

 

 

M = Clearance under veranda, porch, deck or

12” (30cm)‡

12” (30cm)‡

 

 

balcony

 

 

 

N = Clearance above a roof shall extend a minimum of 24” (610mm) above the highest point when it passes through the roof surface, and any other obstruction within a horizontal distance of 18” (450mm).

1 In accordance with the current CSA-B149 Installation Codes

2 In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes

A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings

‡ only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: NOTE: 1. Local codes or regulations may require different clearances.

2.The special venting system used on Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.

3.CFM Corporation assumes no responsibility for the improper performance of the appliance when the venting system does not meet these requirements.

Fig. 11 Vent termination clearances.

10

20009543

Image 10
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Mantel Surround Framing DimensionStandard Framing CriticalMantels Clearance to CombustiblesHearth Framing and Finishing Nailing flangesGas Specifications Gas Line InstallationFinal Finishing Gas Inlet and Manifold PressuresElectrical Junction Box E Units Only Remote ON/OFF SwitchElectronic Gas Control Valve General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationUSA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Restrictor Plate GuideHorizontal Termination ApplicationSidewall Applications Mm on the bottomAlways install horizontal venting on a level plane Sidewall InstallationStep Sidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstalling the 38S2VDK Door Installation ProcedureRestrictor plate use in straight up installation Turn shutter plate over to cover opening Vertical Through-the-Roof Installation Installing firestop spacerMin 610mm Chimney Components Component Description Model NumberRestrictor Plates Installation Glass Frame Assembly RemovalGlass Cleaning Operating InstructionsCeramic Refractory Installation Log, Lava Rock and Ember PlacementLava rock and ember placement Position the log front right. Hold the log Flame Characteristics Flame & Temperature AdjustmentRN/RP & EN/EP Models Trim Installation Trim frame in placeLighting and Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting and Operating InstructionsLighting Instructions ValveTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveSIT 822 Valve with a Honeywell Electronic Ignitor Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Allow unit to cool if it has been operatingPilot Flame Adjustment Replace regulatorCleaning Electronic Ignition System MaintenanceCleaning the Standing Pilot Control System Battery Replacement for Ignitor ModuleDVT38S2 Decorative Gas Appliance DVT38S2 DVT38S2DVT38 Fuel Conversion KitsFull Surround Mantel AccessoriesRemote Controls Model Functions ControlledLimited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %