Vermont Casting DVT38S2 Installation & Operating Instructions, Locating Your Fireplace

Page 3

Chateau™ Decorative Gas Appliance

Installation & Operating Instructions

This gas fireplace should be installed by a qualified installer in accordance with local building codes and with current CSA- B149.1 Installation codes for Gas Burning Appliances and Equipment. For USA Installations follow local codes and/or the current National Fuel Gas Code. ANSI Z223.1/NFPA 54.

In the Commonwealth of Massachusetts, all gas fittings and installation of this appliance shall be done by a licensed gas fitter or licensed plumber.

FOR SAFE INSTALLATION AND OPERATION PLEASE NOTE THE FOLLOWING:

1 . This fireplace gives off high temperatures and should be located out of high traffic areas and away from furniture and draperies.

2.

Children and adults should be alerted to the hazards of the

 

high surface temperatures of this fireplace and should stay

 

away to avoid burns or ignition of clothing.

3.

CAUTION: Due to high glass surface temperature chil-

 

dren should be carefully supervised when in the same

 

room as fireplace.

4.

Under no circumstances should this fireplace be modified.

 

Parts removed for servicing should be replaced prior to

 

operating this fireplace again.

5.

Installation and any repairs to this fireplace must be per-

 

formed by a qualified installer, service agency or gas sup-

 

plier. A professional service person should be contacted to

 

inspect the fireplace annually. More frequent cleaning may

 

be required due to excess lint and dust from carpeting, bed-

 

ding material, etc.

6.

Control compartments, burners and air passages in this fire-

 

place should be kept clean and free of dust and lint. Make

 

sure that the gas valve and pilot light are turned off before

 

you attempt to clean this fireplace.

7.

The venting system (chimney) of this fireplace should be

 

checked at least once a year and if needed your venting

 

system should be cleaned.

8.

Keep the area around your fireplace clear of combustible

 

materials, gasoline and other flammable vapor and liquids.

 

This fireplace should not be used as a drying rack for cloth-

 

ing, nor should Christmas stockings or decorations be hung

 

on or around the fireplace.

WARNING: Check with your electronics manufac- turer before installing a television or other electronic device above this fireplace.

This appliance may be installed in an aftermarket permanently located, manufactured home or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

The DVT38S2 has been approved for mobile home installations.

IMPORTANT:

PLEASE REVIEW THE FOLLOWING CAREFULLY

Remove any plastic from parts before turning the fireplace ON.

It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine.

It is not unusual for your gas fireplace to give off some odor the first time it is burned. This is due to the curing of the paint and any undetected oil from the manufacturing process.

Please ensure that your room is well ventilated-open all windows.

It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it.

Locating Your Fireplace

D A

Y

9. Under no circumstances should any solid fuels (wood, coal,

paper or cardboard etc.) be used in this fireplace.

10. The flow of combustion and ventilation air must not be ob-

structed in any way.

11. When the fireplace is installed directly on carpeting, vinyl tile

or any combustible material other than wood, this fireplace

must be installed on a metal or wood panel extending the

full width and depth of the fireplace.

12. This fireplace requires adequate ventilation and combustion

Y

B

C

E

X

LU584-1

air to operate properly.

13. This fireplace must not be connected to a chimney flue

serving a separate solid fuel burning fireplace.

14. When the fireplace is not in use it is recommended that the

gas control valve be left in the “OFF” position.

NOTE: This appliance uses a fast acting thermocouple and must be replaced with same.

Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6

Fig. 1 Locate gas fireplace.

A) Flat on wall

B) **Island

C) *Room divider

D) *Flat on wall corner

E) Chase installation

Y) 6” minimum

Note (Fig. 1):

**Island (C) and Room Divider (D) installation is possible as long as the horizontal portion of the vent system (X) does not exceed 20’ (610cm). See details in Venting Section.

* When you install your fireplace in (D) Room divider or (E) Flat on wall corner positions (Y), a minimum of 6” (152mm) clearance must be maintained from the perpendicular wall and the front side edge of the fireplace.

3

Image 3
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Critical DimensionStandard Framing Mantel Surround FramingClearance to Combustibles MantelsHearth Nailing flanges Framing and FinishingGas Inlet and Manifold Pressures Gas Line InstallationFinal Finishing Gas SpecificationsRemote ON/OFF Switch Electrical Junction Box E Units OnlyElectronic Gas Control Valve Location of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Canadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Application Restrictor Plate GuideHorizontal Termination Vertical TerminationMm on the bottom Sidewall ApplicationsSidewall Installation Always install horizontal venting on a level planeStep Horizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstallation Procedure Installing the 38S2VDK DoorRestrictor plate use in straight up installation Turn shutter plate over to cover opening Installing firestop spacer Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsOperating Instructions Glass Frame Assembly RemovalGlass Cleaning Restrictor Plates InstallationLog, Lava Rock and Ember Placement Ceramic Refractory InstallationLava rock and ember placement Position the log front right. Hold the log Flame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models Trim frame in place Trim InstallationTo Turn Off Gas To Heater Lighting and Operating InstructionsValve Lighting and Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Ignitor Allow unit to cool if it has been operating Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsReplace regulator Pilot Flame AdjustmentBattery Replacement for Ignitor Module MaintenanceCleaning the Standing Pilot Control System Cleaning Electronic Ignition SystemDVT38S2 Decorative Gas Appliance DVT38S2 DVT38S2Fuel Conversion Kits DVT38Model Functions Controlled AccessoriesRemote Controls Full Surround MantelProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings