Vermont Casting DVT38S2 installation instructions Turn shutter plate over to cover opening

Page 18

Chateau™ Decorative Gas Appliance

For LP gas venting straight vertical with 20’ (6 m) or more, adjust the primary air to the burner housing as well as the fresh air to the unit by doing the following:

1.Remove glass, logs, glowing embers (if installed).

2.Remove andirons, fettles and burner housing.

3.Remove the two (2) screws securing the deflector and the rectangular restrictor plate in place. (Fig. 29) Turn the restrictor plate around so the body of the plate will extend down over the air opening.

4.Turn the burner housing upside down. Remove the two (2) screws securing the shutter plate to the bottom of the burner. Turn the shutter plate around so the bottom opening is 1” (25 mm). Replace the screws removed earlier. (Fig. 30)

5.Reinstall burner housing, fettle, andirons, logs and glowing embers in reverse order. (Refer to Page xx for log installation)

Rectangular Restrictor Plate

Deflector

Screws

FP1615

Fig. 29 Turn rectangular restrictor plate over to partially cover opening.

Shutter

Remove Screws

 

Plate

 

 

Shutter Plate

1“ (25 mm)

FP1616a

Fig. 30 Turn shutter plate over to cover opening.

For vertical venting configurations that include a minimum vertical rise of 12’ (3.7 m) and a maximum horizontal offset of 10’ (3 m) the 4¹⁄₂” restrictor plate supplied with this unit should be used on LP unit only. (Fig. 31) Refer to Page 32, Figure 39 for restrictor plate installation.

 

FP1462

Fig. 31

Restrictor plate use with horizontal offset.

This Gas Fireplace has been approved for,

Vertical installations up to 40’ (12 m) in height. Up to a 20’ (6 m) horizontal vent run can be installed within the vent system using a maximum of three (3) 90° elbows. (Fig. 32)

Max. 20' (6m)

Max. Height

40' (12m)

Min. Height

12' (3.7m)

Pipe Straps Every 3’ (914mm)

FP1463

Fig. 32 Support straps for horizontal runs.

18

20009543

Image 18
Contents INSTALLER/CONSUMER Safety Information What to do if YOU Smell GASTable of Contents Installation & Operating Instructions Locating Your FireplacePlease Review the Following Carefully Mantel Surround Framing DimensionStandard Framing CriticalClearance to Combustibles MantelsHearth Framing and Finishing Nailing flangesGas Specifications Gas Line InstallationFinal Finishing Gas Inlet and Manifold PressuresRemote ON/OFF Switch Electrical Junction Box E Units OnlyElectronic Gas Control Valve General Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Vertical Termination Restrictor Plate GuideHorizontal Termination ApplicationSidewall Applications Mm on the bottomSidewall Installation Always install horizontal venting on a level planeStep Sidewall Installation with Stationary Glass Facing Outside Horizontal length requirementInstalling the 38S2VDK Door Installation ProcedureRestrictor plate use in straight up installation Turn shutter plate over to cover opening Vertical Through-the-Roof Installation Installing firestop spacerMin 610mm Chimney Components Component Description Model NumberRestrictor Plates Installation Glass Frame Assembly RemovalGlass Cleaning Operating InstructionsCeramic Refractory Installation Log, Lava Rock and Ember PlacementLava rock and ember placement Position the log front right. Hold the log Flame & Temperature Adjustment Flame CharacteristicsRN/RP & EN/EP Models Trim Installation Trim frame in placeLighting and Operating Instructions To Turn Off Gas To HeaterTurning Off the Gas to the Appliance Lighting and Operating InstructionsLighting Instructions ValveTroubleshooting the Gas Control System SIT Nova 820 Millivolt ValveSIT 822 Valve with a Honeywell Electronic Ignitor Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Allow unit to cool if it has been operatingPilot Flame Adjustment Replace regulatorCleaning Electronic Ignition System MaintenanceCleaning the Standing Pilot Control System Battery Replacement for Ignitor ModuleDVT38S2 Decorative Gas Appliance DVT38S2 DVT38S2DVT38 Fuel Conversion KitsFull Surround Mantel AccessoriesRemote Controls Model Functions ControlledLimited Lifetime Warranty Product Covered by this WarrantyEfficiency Ratings Model EnerGuide Ratings Fireplace Efficiency %