Vermont Casting DVT38S2 installation instructions Position the log front right. Hold the log

Page 25

8.Position the log left grate. (Fig. 47) Hold the log with your left hand with the pointed end toward the right and the flat surface facing down. Set the log on the inside of the fettle toward the left over the overlay and hook the branch and the pointed end of the log through the first and second opening on the fettle by using the second and third tine. When the log is in place, it will be sitting at an angle in the air above the overlay. Repeat this step for opposite side.

Log Left Grate

LG427

Log Left Grate

Fig. 47 Position log left grate.

9.Position the log middle. (Fig. 49) Familiarize yourself with notches located on the flat surface of the log on each end. (Fig. 48) These notches are utilized in positioning the log. Hold the log with the flat surface facing down and the burned out end closer to you.

NOTE: Position this log through the side with the con- trol valve box on the left side. Set the log using the notches mentioned earlier located on the flat surface of the log and using the fourth “middle” tine on each fettle. When the log is in place, the notches located on the bottom of the log will set directly above the fourth “middle” tine on each fettle.

Bottom View

Notch

NOTE: These notches will fit onto the fourth middle tine of each fettle.

Chateau™ Decorative Gas Appliance

Log Middle

LG429

Fourth “Middle” Tine

Fig. 49 Position log middle.

10.Position the log right grate. (Fig. 50) Hold the log with your right hand with the pointed end toward the left and the flat surface facing down. Hook the notch located on the right corner of the log through the first opening on the right hand side of the fettle using the first tine. Bring the log toward you until it comes in contact with the fettle. Then rest the pointed end over the middle log positioned in Step 9. Repeat this step for opposite side.

Log Right Grate

LG430

Fig. 50 Position log right grate.

11. Position the log front right. (Fig. 51) Hold the log

with the two (2) branches toward you. Set the left

branch on the inside of the second tine of the fettle

and drop the right branch on the overlay behind the

log positioned in Step 7. Lay the other end of the log

over the notch located on the log positioned in Step

10. Make sure to clear the opening on the overlay

when looking straight down.

12. Position the log front upper right. (Fig. 52) Hold the

log with narrow end toward you. Set the narrow end

over the flat notch on the log right grate positioned

in Step 10. Lay the wide end of the logs over the

Notch

LG428

branch on the log left grate positioned in Step 8.

Fig. 48 Use notches on bottom side of log to set in place.

20009543

25

Image 25
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Locating Your Fireplace Installation & Operating InstructionsPlease Review the Following Carefully Standard Framing DimensionMantel Surround Framing CriticalMantels Clearance to CombustiblesHearth Nailing flanges Framing and FinishingFinal Finishing Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresElectrical Junction Box E Units Only Remote ON/OFF SwitchElectronic Gas Control Valve Location of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information Assembling Vent Pipes SK8 Venting Pipes Horizontal Termination Restrictor Plate GuideVertical Termination ApplicationMm on the bottom Sidewall ApplicationsAlways install horizontal venting on a level plane Sidewall InstallationStep Horizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstallation Procedure Installing the 38S2VDK DoorRestrictor plate use in straight up installation Turn shutter plate over to cover opening Installing firestop spacer Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plates Installation Operating InstructionsLog, Lava Rock and Ember Placement Ceramic Refractory InstallationLava rock and ember placement Position the log front right. Hold the log Flame Characteristics Flame & Temperature AdjustmentRN/RP & EN/EP Models Trim frame in place Trim InstallationTo Turn Off Gas To Heater Lighting and Operating InstructionsLighting Instructions Lighting and Operating InstructionsTurning Off the Gas to the Appliance ValveSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Allow unit to cool if it has been operatingReplace regulator Pilot Flame AdjustmentCleaning the Standing Pilot Control System MaintenanceCleaning Electronic Ignition System Battery Replacement for Ignitor ModuleDVT38S2 Decorative Gas Appliance DVT38S2 DVT38S2Fuel Conversion Kits DVT38Remote Controls AccessoriesFull Surround Mantel Model Functions ControlledProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings