Vermont Casting DVT38S2 installation instructions Restrictor plate use in straight up installation

Page 17

2.Install the two (2) brackets, using the sheet metal screws, at the bottom right and left corners of the unit. (Fig. 27)

Bracket

Sheet Metal

Screws

FP1481

Fig. 27 Use sheet metal screws to attach brackets to existing holes under glass frame assembly.

3.Set the glass frame assembly provided with your kit in front of the glass frame assembly on the unit (the outside side).

4.Have the machine screws provided with the kit within reach.

5.Unfasten the two (2) machine screws that secure the glass frame assembly to the unit and discard. Slide the glass frame assembly provided with the kit over the surround around the glass frame assembly on the side and top.

WARNING: The glass frame assembly provided with the unit must be left in place for proper operation. Failure to do so could cause property damage and malfunction of the unit.

6.Fasten the two (2) long machine screws at the top through the two (2) glass frame assemblies and fas- ten the two (2) short machine screws at the bottom right and left corner into the bracket installed earlier.

Chateau™ Decorative Gas Appliance

Vertical Through-the-Roof

Applications

Use of Restrictor Plate

for Vertical Venting Application

The primary purpose for the vent restrictor is to regain flame height under certain venting conditions as outlined below.

NOTE: The joints of the inner pipe (flue pipe) must be taped with 550°F or higher temperature metal adhesive tape that meets the requirements of F.A.R. 25.853(a). High temperature sealant milpack or stove cement

of 550°F or higher could be used instead. The joints of The outer pipe (fresh air pipe) must be taped with 315°F or higher temperature metal adhesive tape or the use of high temperature milpack or stove cement would be applicable. When using the unitized 30°, 45° or 90° elbows, apply 1/4” bead of high temperature, 550°F or higher, sealant (milpack or stove cement) to the joint of the inner pipe (flue pipe) and the straight section as it is impossible to be taped. The outer pipe must be taped with 315°F high temperature metal adhesive tape for proper sealing.

For vertically venting either propane or natural gas units, with vertical vent heights of 12’ (3.7m) or greater, (measured from the top of the flue collar) the restrictor plate as supplied with this unit should be used. (Fig.

28)Refer to Page 21, Figure 37 for restrictor plate installation.

X

FP1461

Fig. 28 Restrictor plate use in straight up installation.

20009543

17

Image 17
Contents What to do if YOU Smell GAS INSTALLER/CONSUMER Safety InformationTable of Contents Please Review the Following Carefully Installation & Operating InstructionsLocating Your Fireplace Standard Framing DimensionMantel Surround Framing CriticalHearth Clearance to CombustiblesMantels Nailing flanges Framing and FinishingFinal Finishing Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresElectronic Gas Control Valve Remote ON/OFF SwitchElectrical Junction Box E Units Only Location of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2General Information Assembling Vent Pipes SK8 Venting Pipes Canadian InstallationsUSA Installations Horizontal Termination Restrictor Plate GuideVertical Termination ApplicationMm on the bottom Sidewall ApplicationsStep Sidewall InstallationAlways install horizontal venting on a level plane Horizontal length requirement Sidewall Installation with Stationary Glass Facing OutsideInstallation Procedure Installing the 38S2VDK DoorRestrictor plate use in straight up installation Turn shutter plate over to cover opening Installing firestop spacer Vertical Through-the-Roof InstallationMin 610mm Component Description Model Number Chimney ComponentsGlass Cleaning Glass Frame Assembly RemovalRestrictor Plates Installation Operating InstructionsLog, Lava Rock and Ember Placement Ceramic Refractory InstallationLava rock and ember placement Position the log front right. Hold the log RN/RP & EN/EP Models Flame & Temperature AdjustmentFlame Characteristics Trim frame in place Trim InstallationTo Turn Off Gas To Heater Lighting and Operating InstructionsLighting Instructions Lighting and Operating InstructionsTurning Off the Gas to the Appliance ValveSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Ignitor Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Allow unit to cool if it has been operatingReplace regulator Pilot Flame AdjustmentCleaning the Standing Pilot Control System MaintenanceCleaning Electronic Ignition System Battery Replacement for Ignitor ModuleDVT38S2 Decorative Gas Appliance DVT38S2 DVT38S2Fuel Conversion Kits DVT38Remote Controls AccessoriesFull Surround Mantel Model Functions ControlledProduct Covered by this Warranty Limited Lifetime WarrantyModel EnerGuide Ratings Fireplace Efficiency % Efficiency Ratings