Enviro C-10381, C-11290 owner manual Component Sound & Reason

Page 8

Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

Remote controls (Optional):

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

Blower Speed (Optional):

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off.

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

Normal Sounds During Operation:

 

Table 2: Normal Sounds

 

 

Component

Sound & Reason

 

 

Westport

Creaking when heating up or cooling down.

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

 

 

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

8

Image 8
Contents Installer ConsumerSafety Precautions GeneralTable of Contents Rear Vent DV Codes And ApprovalsTOP Vent DV Specifications Westport Exterior DimensionsOperatingInstructions MAYOperating Instructions Pilot FlameComponent Sound & Reason Maintenance And Service Electronic Ignition Module LocationTo Replace Handles for Removing DoorKit Parts List Conversion Kit InstallationRemove the black protection cap from Initial Installation Qualified Installers onlyRound Support Vent Termination Restrictions Installation Instructions KIT ComponentsInstallation of Fireplace Horizontal Vent Kit Manufacturer Trade Name Nominal Sizes4DSC Shows the vent restrictor position required, relative to 51mm at top, 1½ 38mm at sides, 1½ 38mm at Bottom Twist-Lock ConnectionTermination Pipe and elbows may be utilized in the attic, as Over 18/12 to 20/12 Over 20/12 to 21/12 Follow installation steps 1 & 2 under Initial Do not interfere with the structural integrity of the walls 33a-2002 Test Methods and the Resulting ITS Firebox Top Corner Installation Installation for Top Vented Horizontal TerminationInstallation Wiring DiagramCanadian Installations A. InstallationsVenting of a Fireplace Fitted with the Drafthood Adaptor Spillage TestOptional Finishing Automatic Safety Shut DownSpill Switch Replacement GAS Line Connection To Test Valve PressuresWire Size Max. Length Wiring Diagram For Fan ControlSecondary Installation Optional Blower Fan InstallationComplete Log Placement Log Placement with Rock Wool Brick panel bracket, slots shown Trouble Shooting Problem Possible Cause SolutionParts List Cast Reference Part Description Part NumberEGWP-505PG EGWP-501PG Parts Diagram Cast Parts List Components Parts List Components Parts Diagram Components Warranty To the DealerWarranty Installation Data Sheet